A mobile robotic chemist

Paper · 2020 · Benjamin Burger, Phillip M. Maffettone, Vladimir V. Gusev et al.

Summary

A mixture can be hard to improve even when every ingredient is familiar. An additive that helps on its own may have a different effect when it is combined with a dye, a salt, or another additive. Testing every combination quickly becomes impractical, and testing ingredients one at a time can miss useful combinations. Burger and colleagues addressed this problem with a mobile robot that could prepare samples, carry them between laboratory instruments, and use completed measurements to choose further experiments. They asked whether it could improve a photocatalyst mixture that produces hydrogen from water under illumination.

The authors began by screening 30 candidate hole scavengers, compounds that help a photocatalyst sustain hydrogen production by accepting the positive charges created under illumination. L-cysteine stood out among the candidates, although it produced hydrogen more slowly than triethanolamine at the same mass concentration. The authors then chose ingredients to investigate several possible routes to improving the cysteine mixture, including changing the acidity, adding salt, and trying additives that might help the catalyst absorb light or come into contact with water. Together with the amounts of catalyst and cysteine, those choices defined a 10-variable search.

The robot ran 688 experiments over 8 days in a space of 98,423,325 possible settings. A batched Bayesian search used the results of previous experiments to estimate which recipes might perform well and which remained uncertain. The strongest mixture measured in the campaign contained the polymer photocatalyst P10, L-cysteine, sodium hydroxide, and sodium disilicate. It produced hydrogen at 21.05 µmol h⁻¹. The starting P10 and L-cysteine formulation gave 3.36 ± 0.30 µmol h⁻¹, so the authors describe the improvement as six times the starting rate. The search also moved away from the dyes and surfactants it had tried, and an additive that appeared unpromising early in the run eventually became part of the best mixture.

The result depended on making experimental work and experimental selection run together. The robot used laser scanning to navigate and touch to align itself precisely at a workstation. It could handle both solids and liquids, load samples into instruments, and return the measurements to the search. Several stages could overlap, allowing preparation and illumination to proceed while another batch was being analyzed. Researchers supplied the initial hypotheses, the ingredient choices, and the measure of success. Within that remit, the system found a better formulation and recorded a search history that helped the authors interpret how the ingredients affected performance.

Deep dive: A mobile robotic chemist

A mobile robotic chemist used Bayesian optimization to search for photocatalyst mixtures that produce hydrogen from water more quickly. · about 35 minutes to read

The problem and its context

Why formulation is a search problem

In the kinds of materials that motivate the paper, useful behavior emerges from components acting together across different physical scales. The authors give batteries, biomaterials, and heterogeneous catalysts as examples. Molecular composition matters, but so can the arrangement and interaction of components at scales above individual molecules. The authors describe this combination of scales as a barrier to complete atomistic simulation and explain why design from first principles remained unusual for such materials. Experimental formulation was therefore still a central way to look for better performance.

Formulation experiments have a difficulty that is easy to miss when looking at a list of ingredients. A component can be present or absent, and an included component can be present at different concentrations. Even when an instrument allows only a limited set of doses, a new ingredient adds many possible recipes. The number grows rapidly as ingredients accumulate. A laboratory may have the time to explore a few hundred mixtures and still cover only a small part of the space it has defined. Picking a narrow region in advance makes the work manageable, but the choice can rule out an interaction before anyone has had a chance to see it.

Changing a single ingredient while holding the others fixed can answer a question about the chosen background mixture. It gives a weaker basis for deciding whether the ingredient will help in a different background. Burger and colleagues illustrate the issue with salt and dye. A change in ionic strength might affect how a dye associates with the catalyst surface, and the resulting effect might favor or impair hydrogen production. Measuring a salt effect in a recipe without dye, and then a dye effect at one fixed salt concentration, would leave much of that joint behavior unexamined. The authors were interested in a search that could vary ingredients together while limiting how many recipes actually had to be made.

The practical burden was also broader than dispensing ingredients. A useful photocatalysis measurement requires samples to move through preparation, reaction, and chemical analysis. Materials research uses solids as well as liquids, and each operation can have its own physical demands. Automating one instrument can make that operation faster while leaving a researcher to transfer every sample to the next station. The larger the search, the more consequential those repeated transfers become. If results must also be interpreted before the next recipes can be chosen, the decision step becomes part of the same workflow.

What earlier automation had already shown

The paper places the project among two strands of earlier work. One had already used automated experimentation with artificial intelligence for problems such as continuous-flow reactions, photovoltaic films, organic synthesis, and perovskite experiments. The authors also cite previous work on formulation and on coordinating autonomous experiments. That work supplied precedents for selecting experiments from measurements and for organizing equipment around a task. The distinct question here was whether those kinds of decisions could guide a robot that moves through a shared laboratory and physically operates multiple workstations.

The other strand concerned mobile robots and dexterous handling. The paper cites work on transport, grasping, and navigation in life science laboratories, as well as mobile manipulation elsewhere. Moving a load to a destination and manipulating it accurately at that destination are separate challenges. A mobile base can get close enough to a bench for transport while still being too far out of alignment to seat a vial. Burger and colleagues needed a platform that could do both, and that could combine those movements with the timing and decisions required by a chemical experiment.

The authors had also developed a semi-automated approach to measuring photocatalytic hydrogen evolution. That experience gave them a concrete intermediate case between manual work and an unattended search. Automated dispensing and measurement could already reduce repetitive effort. A researcher still had to set up the work, and the semi-automated procedure did not run the full cycle of choosing new formulations, preparing them, and measuring them over multiple days. The mobile platform was meant to connect those stages while using much of the laboratory equipment in its usual physical form.

Why focus on hydrogen evolution

The chemical objective was to improve a formulation for producing hydrogen from water under illumination. A semiconductor photocatalyst absorbs light and creates charges that can participate in chemical reactions. The positive charge left by excitation is called a hole. A hole scavenger gives that charge a reaction partner, helping the photocatalyst continue to drive hydrogen formation. In many systems described by the authors, this requires a sacrificial compound. The compound is consumed as the reaction proceeds.

The authors distinguish this kind of hydrogen evolution from overall water splitting, in which both hydrogen and oxygen are produced. They describe effective semiconductor photocatalysts for overall water splitting as uncommon. Triethylamine and triethanolamine were established examples of scavengers that supported hydrogen evolution, but the reactions decomposed them irreversibly. The immediate goal was to find a bioderived alternative with useful activity. The longer-term aim was a reversible redox shuttle, meaning a compound that can alternate between chemical forms and be regenerated as it transfers charge.

P10 gave the authors a starting point. It is a conjugated polymer, a material whose connected electronic structure makes it relevant to light-driven reactions. Earlier work had shown that P10 could produce hydrogen at a useful rate with triethanolamine. The authors could therefore hold the identity of the photocatalyst fixed during the initial scavenger screen and ask which other molecules supported activity with it. Once they had a promising scavenger, they could use the same experimental platform to ask a different question about the surrounding formulation.

That second question drew on earlier chemical observations. The authors had seen a dye improve hydrogen evolution in a structurally related framework, and earlier work had given them reason to consider the wettability of polymer photocatalysts. They also had reasons to investigate ionic strength, pH, and interactions between additives and surfaces. These observations made the proposed ingredients plausible. They left open both the direction of the effect in P10 and the conditions under which it might appear. That uncertainty is what made the problem suitable for an experimental search.

The method, step by step

From an experimental question to a batch of samples

The study used the same physical workflow for two different ways of making decisions. In the scavenger screen, the researchers selected the candidate molecules in advance. A simple rule told the system when to reanalyze a promising sample. In the formulation search, the researchers defined the ingredients, allowable amounts, and target measurement. The software then selected recipes using the experimental results accumulated during the search. The distinction matters because the robot could execute a predetermined set of experiments without needing Bayesian optimization. Optimization entered when choosing the next recipes became part of the task.

A formulation was a set of quantities the dispensing stations could deliver to a vial. The measurement associated with it was how quickly the sample produced hydrogen under the assay conditions. Once those quantities and the measurement were represented in software, the search could specify experiments in the same terms that the laboratory equipment used. The robot and instruments carried out the operations. The optimizer could then use the returned measurement to evaluate the region of composition space from which the recipe came.

How the autonomous formulation search ran

The steps in order.

How the autonomous formulation search ranStep 1: Select a batch of feasible recipes1. Select a batch of feasible recipesStep 2: Dispense solids and liquids into vials2. Dispense solids and liquids into vialsStep 3: Seal vials and disperse solids when needed3. Seal vials and disperse solids when neededStep 4: Illuminate the samples4. Illuminate the samplesStep 5: Measure headspace hydrogen by gas chromatography5. Measure headspace hydrogen by gas chromatographyStep 6: Update the search with usable measurements6. Update the search with usable measurementsStep 7: Choose another batch7. Choose another batch

The batch was the unit that linked decision-making to sample handling. The robot transported vials in a rack, and the instruments took time to prepare, illuminate, or analyze the samples. Choosing several recipes together allowed the search to fit that physical organization. The software had to make its choices before measurements for the newly selected recipes were available. It therefore needed a way to use the positions in a batch for different kinds of opportunity, including recipes with good predicted performance and recipes where a measurement would resolve substantial uncertainty.

How the robot reached and used the workstations

The mobile platform carried an articulated arm and a gripper designed for the objects in the workflow. Its reach was 820 mm, and the arm had a maximum payload of 14 kg. The paper gives 580 g as the mass of a rack of filled vials, illustrating that the arm was sized with other possible laboratory operations in mind. Its reach and height were already useful in the demonstrated workflow because they let it load the gas chromatograph directly at its ordinary working height.

The gripper could grasp an uncapped vial from the side, a capped vial from the top, a solid-dispensing cartridge, and an entire rack. For the rack, it used an outward grasp engaging recesses in the carrier. The same gripper could physically press a button on the gas chromatograph. These examples show the practical meaning of instrument compatibility in this study. A station could accept a vial or rack in the same place it usually would, and the robot could perform some of the actions that would ordinarily be done by hand. Software coordination was still needed for the operations that took place inside the instruments.

Navigation and local positioning used different information. In the 7.3 m x 11 m laboratory, the robot compared its laser scans with a map. It maintained a set of possible positions and updated its estimate according to how well each fit the scan. The estimated pose had a horizontal location and a heading. Across 563 movements, the paper reports horizontal positioning precision better than ± 10 mm and orientation precision of less than ± 2.5 degrees. That was sufficient for reaching stations and stopping in their vicinity.

For handling a vial, the relative position of the instrument matters more than the robot's approximate position on the room map. At a station, the robot touched six points on a fixed reference cube. The points of contact determined where the cube was and how it was oriented with respect to the robot. With the station referenced to the cube, the arm could carry out the fine movements needed for placement and loading. After this procedure, the reported positioning precision was ± 0.12 mm and the orientation precision was ± 0.005 degrees. The station layout could also make one calibration serve several related operations. The robot could reach the liquid dispensing stations and the capper from the same calibrated position.

The robot's navigation and positioning did not depend on visible illumination. Laser scanning supplied the map-based information, and contact supplied the local reference. The authors note that the robot could therefore operate in darkness, a feature relevant to experiments involving light-sensitive materials. The arm and base also met standards for collaborative robots, and travel speed was restricted to 0.5 m s⁻¹ for safety. Shared use of the laboratory was part of the platform's design.

How a sample moved through the laboratory

The solid dispenser weighed P10 into sample vials. The polymer had been ground before dispensing. The robot could load both the vials and the dispensing cartridge, while the dispenser performed the weighing. The vial rack then moved to liquid handling. There, a pump dispensed liquid and a scale supplied feedback so that delivery could be controlled by the measured mass. The authors report observing good accuracy and precision across aqueous and non-aqueous liquids in 20,000 dispensing operations.

The next station displaced oxygen from the vial headspace using nitrogen and crimped a cap onto the vial. Headspace is the gas-filled region above the liquid. It was important both to exclude oxygen during the procedure and to leave a consistent gas volume for the later measurement. A seal could fail, and the system treated an excessive oxygen measurement as grounds for excluding a result. Researchers could include a sonication step to disperse the solid photocatalyst in the liquid before illumination. This step was optional in the general workflow.

At the photolysis station, the samples received ultraviolet and visible light while vibration agitated the liquid. Photolysis here is the light exposure during which the photocatalytic reaction took place. Its output went to a different instrument. The robot moved the rack to a headspace gas chromatograph, which analyzed the gas above the sample for hydrogen. The measured hydrogen entered the experimental record, and the robot moved the completed vials to storage.

The division of work between the robot and the stations is central to the engineering. The robot handled transfer, loading, and selected instrument actions. The equipment carried out weighing, dosing, capping, light exposure, and analysis. The Methods describe a liquid station assembled for gravimetric dispensing and dedicated hardware for capping and photolysis. The solid dispenser and the gas chromatograph were commercial instruments, with the paper explicitly identifying the chromatograph as physically unmodified. The resulting laboratory combined existing instruments with purpose-built equipment where the experimental sequence called for it.

A process management system held the logic for coordinating the stations. It communicated with devices over the interfaces those devices supported and released jobs as they became available. The scheduling rule gave the robot the oldest available job. Once an instrument had a rack and was carrying out its task, the robot could leave and work elsewhere. This allowed the time taken by an instrument and the time taken by robotic handling to overlap. The system also charged the robot between jobs once the battery reached a 25% threshold and could alert an operator to low stocks or workflow faults.

How the researchers defined the chemical space

In the initial screen, the robot worked through 30 candidate scavengers. The main screening description gives 50 g L⁻¹ aqueous solutions, with the extended data identifying the stock concentration used for each candidate. That figure specifies 5 mL of solution and 5 mg of P10 for the screening assay. The conditional rule concerned the hydrogen evolution rate, abbreviated HER. A sample with a rate of >200 µmol g⁻¹ h⁻¹ was automatically reanalyzed five times. This rate was expressed per mass of photocatalyst as well as per hour. The repeat rule concentrated follow-up on the samples that cleared the threshold.

For the search that followed, the authors started with P10 and L-cysteine and chose additives that represented several chemical hypotheses. To investigate whether a dye might improve light absorption, they included Rhodamine B, Acid Red 87, and methylene blue. To test the effects of changing acidity and dissolved salt, they included sodium hydroxide and sodium chloride, respectively. Sodium hydroxide could raise pH, while sodium chloride provided a way to change ionic strength. Ionic strength concerns the amount and charge of dissolved ions and is relevant here because ions can influence interactions in the mixture.

The researchers also asked whether changing how well the liquid wets the solid catalyst could affect the outcome. They included the surfactants sodium dodecyl sulfate and polyvinylpyrrolidone for that purpose. Finally, they included sodium disilicate because they suspected it could help bind scavenger or dye near a surface through hydrogen bonding. They based that possibility on earlier observations about dyes and carbon nitride. The five hypotheses supplied reasons to include the additives. The experiment let their quantities vary together so that their effects could appear in different chemical backgrounds.

The quantities of P10 and L-cysteine varied along with those of the additives. The liquid volume was fixed at 5 mL to maintain comparable headspace for gas analysis. Increasing the amount of a stock solution therefore used some of a limited volume. The authors describe the resulting composition space as a simplex. Here that means the liquid quantities share a total-volume constraint, so they cannot each be varied independently up to their respective maxima in every recipe. Water was part of the formulation, and the constraints kept the usable recipes compatible with the assay.

The machine could deliver only certain dose increments. The paper gives 0.25 mL as the resolution of liquid dispensing and 1 mg for solid dispensing. Its search-space figure counts 19 concentration settings for each liquid and 21 for P10 within the bounded space. This yielded 98,423,325 points in the defined simplex. The size refers to the recipes allowed by the authors' ingredients, ranges, and dispensing resolution. A finer dose increment or a different set of ingredients would define a different search space.

How observations became predictions

Bayesian optimization is a way to choose experiments when the response is unknown and each new measurement costs time. The search uses a statistical surrogate to represent plausible relationships between recipe and activity. After observing one set of experiments, it can ask what the likely rate is at a recipe it has yet to test and how uncertain that prediction remains. Results from a new batch then revise those estimates. In this paper the objective being predicted was the hydrogen evolution rate.

The authors first express the update using Bayes' theorem.

ϕ_posterior(θ | 𝒟) = ϕ_likelihood(𝒟 | θ) ϕ_prior(θ) / ϕ(𝒟)

Here θ represents a candidate description of the underlying response, and 𝒟 is the experimental data available so far. The vertical bar means “given.” The function ϕ_prior gives the prior weight assigned to θ, and ϕ_likelihood describes how probable the observed data would be under θ. Their product appears in the numerator. The denominator ϕ(𝒟) normalizes the weights so that ϕ_posterior is a probability distribution over θ after the measurements have been taken into account. The equality expresses how the prior and the likelihood together determine the posterior.

The surrogate was a Gaussian process. For this application, it is useful to think of a Gaussian process as a distribution over possible response curves or surfaces. Its kernel describes how strongly the values at different recipes are related. Measurements at one recipe can therefore inform predictions at other recipes according to their similarity. When several levels of a component or several nearby combinations have been tested, those observations can inform predictions across that part of the space. A prediction far from the observations may carry substantial uncertainty.

The authors used a Matérn kernel, a constant scaling term, and a noise term with the same assumed variance throughout the space. The kernel gave the fit a way to represent smoothness, meaning how gradually or sharply activity was expected to vary with composition. Scaling governed the magnitude of variation in the response, while the noise term accounted for measurement variation in the statistical fit. The paper reports refining the form and hyper-parameters through cross-validation on historical photocatalysis data covering 350 experiments. Cross-validation evaluates choices by fitting with part of the available data and checking predictions against observations held aside for that check. Those historical experiments informed the statistical setup. The subsequent formulation measurements supplied the evidence used as the live search proceeded.

The prior formalism allows existing chemical information to be built in. In this application, the Gaussian process encoded statistical assumptions about response, similarity, and measurement noise. The components began with equal initial importance in the search. The authors' chemical judgments instead entered through the choice of P10, the scavenger, the candidate additives, and the ranges and constraints within which the optimizer operated.

How the search chose several experiments at once

An acquisition function gives the search a rule for deciding which recipe is worth measuring next. The rule used here was an upper confidence bound. It gave a recipe credit for both its predicted activity and the amount of uncertainty in that prediction.

α_UCB(x; 𝒟) ≔ μ(x) + βσ(x)

In this expression, x is the recipe, and 𝒟 is the data available when the search scores it. The semicolon separates the recipe being scored from the data the score depends on. The symbol α_UCB denotes the upper-confidence-bound acquisition score, and ≔ means that the right-hand side defines that score. The term μ(x) is the posterior mean, or predicted activity, at x. The term σ(x) is the posterior uncertainty at that recipe. The coefficient β sets the weight given to uncertainty, and βσ(x) is added to μ(x).

With a smaller weight on uncertainty, the score favors recipes the surrogate already expects to perform well. This is exploitation. With a larger weight, a recipe can rank highly even when its estimated mean is lower, because the current data leave more room for the true response to differ. This is exploration. The tradeoff is especially important when early results in a region look poor and much of that region remains unmeasured. An additional experiment might clarify whether the first results apply across the region or reflect the particular combinations that happened to be tested.

The authors built a portfolio of acquisition functions using different values of β. They call the individual acquisition settings markets. The values were distributed unevenly, with an exponential distribution over the degree of greed. This was intended to produce some proposals that strongly favored predicted performance, some that gave uncertainty substantial weight, and many that balanced the two. Since the acquisition functions could be searched separately, the approach generated candidate experiments in parallel. In the paper's description, a search associated with a market could return a maximum or a batch of its highest-ranked maxima.

For each acquisition search, the procedure first sampled many starting points at random. It then used those starting locations for local maximization with SLSQP, a constrained numerical optimizer. The local search treated the composition variables as continuous and enforced the total liquid volume during maximization. The selected recipes were subsequently placed into discrete bins matching instrument precision. The procedure therefore used continuous coordinates for numerical work while keeping track of the discrete settings that corresponded to possible experiments. The paper describes both representations as part of maintaining the search.

There are two different senses of maximization in this procedure. The acquisition search looked for high scores on a surface calculated from the measurements already available. The physical experiments measured hydrogen production at the selected settings. Even a high acquisition score included either a prediction or a contribution from uncertainty, so the instrument measurement remained decisive for judging whether the proposal improved the formulation. As more results arrived, both the expected response and the acquisition scores could change.

The optimizer used scikit-learn and SciPy. The paper reports the availability of the optimizer and robot control code, as well as implementations of the liquid dispensing station, the photolysis station, and the workflow. It also identifies designs for labware developed for the project. Those materials cover different parts of the system because the loop required both experiment-selection software and a physical implementation capable of realizing its decisions.

Experiments and results

The scavenger screen identified a starting point

Most of the 30 scavengers tested with P10 gave little or no hydrogen. L-ascorbic acid reached 256 ± 24 µmol g⁻¹ h⁻¹, and L-cysteine reached 1201 ± 88 µmol g⁻¹ h⁻¹. Both exceeded the automatic follow-up threshold. The reference scavenger, triethanolamine, gave 2985 ± 103 µmol g⁻¹ h⁻¹ at 50 g L⁻¹. The authors compare that rate with the cysteine result at the same mass concentration. These figures describe hydrogen evolution normalized to photocatalyst mass in the screening comparison.

Hydrogen evolution per catalyst mass in the P10 scavenger screen and reference assay

L-cysteine led the bioderived candidates, while triethanolamine gave the highest rate in the comparison.

Hydrogen evolution per catalyst mass in the P10 scavenger screen and reference assayL-ascorbic acid: 256L-ascorbic acid256L-cysteine: 1201L-cysteine1201Triethanolamine reference (this paper): 2985Triethanolamine reference (this paper)2985
The numbers
System or settingµmol g⁻¹ h⁻¹
L-ascorbic acid256
L-cysteine1201
Triethanolamine reference (this paper)2985

The two screening results for bioderived candidates had different implications for the next stage. L-ascorbic acid was a hit under the pre-defined rule. Cysteine was the stronger candidate and the one the researchers took forward. They also used proton nuclear magnetic resonance spectroscopy to examine what happened to cysteine during the reaction. They observed clean conversion to L-cystine. This gave them a chemically identifiable product and a reason to consider a cycle in which cysteine could be regenerated. The proposed redox shuttle was a direction motivated by the observation, while the measured result was conversion under the screening conditions.

Triethanolamine and the later two-component control served different comparisons. The amine provided a reference for how much activity a conventional scavenger could support at the stated mass concentration. The control in the optimization campaign asked what the P10 and cysteine combination achieved before the formulation search added other ingredients. The two comparisons also use different expressions of rate. The screening numbers are normalized by catalyst mass. The main search reports the amount of hydrogen evolved per hour for the experimental vial, which matters because catalyst loading was itself a variable in the search.

The formulation search improved on a recurring control

The optimization baseline contained 5 mg of P10 in 5 mL of a 20 g L⁻¹ L-cysteine solution. Its reported rate was 3.36 ± 0.30 µmol h⁻¹. The authors included two baseline samples per batch to check stability over the unattended run. By keeping that recipe fixed, they had a reference that could be measured throughout a campaign in which most of the samples were deliberately changing. An improvement in a novel recipe could then be interpreted alongside the behavior of a familiar recipe under the same ongoing workflow.

The robot ran 43 batches, which the Methods report as 688 experiments. Of the 688 results, 11 were discarded after workflow errors or oxygen readings the system judged too high. The search started from randomly chosen conditions. The paper reports that the formulations encountered in the first 22 experiments were largely less active than P10 and cysteine alone. The early comparison with the recurring control therefore supplied an important check. Adding more ingredients and having more possible formulations initially produced many mixtures with weaker performance.

A small gain appeared with sodium chloride, and the search also favored higher amounts of P10 and cysteine. During further exploration, recipes containing the tested dyes and surfactants generally performed poorly, and the search moved away from those components after around 150 experiments, or about 2 days. Sodium disilicate emerged as useful in formulations without dyes. The trajectory was more complicated for sodium hydroxide. It was initially passed over, then later returned to the recipes being tested as the broader mixture changed.

The best formulation observed after 43 batches contained P10 at 5 mg, sodium hydroxide at 6 mg, L-cysteine at 200 mg, and sodium disilicate at 7.5 mg, in 5 mL of water. It gave 21.05 µmol h⁻¹. The paper describes that result as six times the starting rate. The experimental comparison is between the recurring P10 and cysteine baseline and the highest rate the search measured. The final recipe changes multiple quantities at once, so the headline gain is a property of the formulation as tested.

Hydrogen evolution per vial in the P10 and L-cysteine formulation search

The best mixture found by the autonomous search produced hydrogen faster than the recurring starting formulation.

Hydrogen evolution per vial in the P10 and L-cysteine formulation searchRecurring P10 and L-cysteine baseline: 3.36Recurring P10 and L-cysteine baseline3.36Best formulation found by the robot (this paper): 21.05Best formulation found by the robot(this paper)21.05
The numbers
System or settingµmol h⁻¹
Recurring P10 and L-cysteine baseline3.36
Best formulation found by the robot (this paper)21.05

The improvement is informative about the experimental problem the authors set. It shows that the initial cysteine result could be developed into a more active formulation by adjusting a mixture of chemicals. The search record adds information that the endpoints alone would miss. Some plausible additives repeatedly gave poor results, some appeared helpful but were later used less, and sodium hydroxide became prominent only later. The optimization outcome and the sequence of trials answer different questions about the campaign.

Virtual searches varied the starting conditions

The physical campaign had a particular random start, so the authors investigated sensitivity to starting conditions in a separate computational exercise. They ran 100 virtual searches. Each began at a different random point, and a regression fit with added random noise supplied the virtual experimental results. The purpose was to repeat the decision procedure against a response surface that could return values without preparing samples. It also allowed a simulated optimum to be used as a reference.

The virtual metric was the number of experiments required to reach a solution with 95% of the maximum hydrogen evolution rate on that surface. The authors report around 160 virtual experiments on average. The paper shows a histogram of the number needed across runs, emphasizing that the search length varied with the starting conditions. The average describes the behavior of the procedure in the virtual setting. The 688 experiments refer to the duration of the real campaign and its highest observed rate. The two counts use different conditions and answer different questions.

Throughput depended on how work overlapped

Over the eight-day search, the robot moved between stations 319 times and traveled 2.17 km. A batch took an average of 183 minutes to prepare and photolyze, followed by 232 minutes for gas chromatography. These times describe stages through which a rack had to pass. The system processed two batches at once, with one in preparation or illumination while the other was being analyzed. The platform could accommodate up to six batches in parallel, but the balance of stage times in this particular workflow led to the observed pattern of overlap.

Extended timing data summarize 46 separate batches and include handling time. The stated light exposure was 60 minutes. Loading and unloading the photolysis station took an average of 28 minutes per batch. Including those handling operations shows why the time needed to run an assay cannot be inferred from illumination time alone. Gas chromatography continued to take the longest, and for about 32% of the campaign the robot had charge but sat idle, mostly as it waited for the chromatograph. The paper identifies this as potential capacity for other work. In the demonstrated search, the availability of measurements still limited how quickly samples could progress through analysis.

The authors estimate that manual measurements would require about 0.5 days of researcher time per experiment. They illustrate the scale of that commitment with 1000 experiments and an estimate of 500 days. Their semi-automated approach could perform 100 experiments per day, with a half-day of setup and another half-day for automatic dispensing and measurement. For 1000 experiments, they give 10 days of elapsed work and 5 days of dedicated researcher time. For the autonomous workflow, they give a half-day of initial setup and estimate 0.5 days of researcher time for 1000 experiments, with the run itself taking place across multiple days.

On that basis, the paper characterizes the autonomous approach as 1,000 times faster than the manual one and at least 10 times faster than the semi-automated one. The accounting behind those claims is dedicated researcher time. The measured elapsed duration of the main campaign was 8 days, and individual preparation and analysis cycles still took hours. The distinction explains what the automation changed. It allowed experiments to keep progressing without occupying a researcher at every preparation, transfer, and measurement step.

What the ablations show

The paper does not report a formal ablation of the optimizer or the robot, but it does analyze how component selection changed, repeat the reference formulation across the campaign, and vary starting conditions in simulation.

Component selection depended on the surrounding mixture

The clearest example is sodium hydroxide. The amount plots show that the search left it out during experiments 15–283. When several other components were still being tested, mixtures containing it did not look promising enough to keep proposing it. Later in the run, sodium hydroxide returned and ultimately appeared in the best recipe. The authors interpret its early performance as a beneficial effect obscured by detrimental ingredients, including dyes. That interpretation fits the fact that the recipe containing it had changed in several respects by the time it became a favored component.

The paper presents this sequence as an illustration of varying the balance between exploration and exploitation across a batch. Once some recipes had performed poorly, an experiment-selection rule that consistently favored only the strongest predictions might have continued to exclude a component associated with those results. Giving uncertainty weight created opportunities to revisit sections of the search space. The paper documents that a component returned and that the final recipe benefited from including an option initially passed over. It gives no parallel run with a fixed acquisition weight that could quantify how much the portfolio itself contributed to the recovery.

The three dyes and two surfactants provide an example with a different trajectory. As measurements accumulated, the search reduced their use and then mostly moved away from them. The authors conclude that all of the dyes and both surfactants tested were harmful to hydrogen evolution in this system. The finding challenges their initial expectations about improving light absorption or wetting. Its strength comes from the availability of many recipes during a multivariable search. Its scope is still the materials and conditions they explored. A different dye, surfactant, catalyst, or amount would be a further experiment.

Acid Red 87 gave the authors an especially concrete comparison to prior work. It had helped a structurally related covalent organic framework, FS-COF, in an earlier experiment. It gave no corresponding benefit here. The paper suggests that porosity could matter because FS-COF is porous and P10 is not. The earlier framework was a chemical precedent for the hypothesis. It was not run as a matched control in the new campaign, and porosity was not isolated as an experimental variable. The cross-material observation motivates the explanation without directly testing it.

A modest effect can matter early and recede later

The result for sodium chloride was consistent with a modest favorable influence of increased ionic strength. It appeared as an early improvement over P10 and cysteine. Later, the search favored conditions involving sodium disilicate and sodium hydroxide, and sodium chloride was no longer included in the strongest formulation. Here the search could discard an ingredient even though the data gave it a useful role in some combinations. Its influence was smaller than the gains associated with other available ingredients.

The authors interpret increased pH as more beneficial than the ionic-strength effect obtained by adding sodium chloride. Sodium hydroxide and sodium disilicate can also increase ionic strength, so the two factors overlap in the observed recipes. The search provides comparative evidence about which ingredient choices worked better in the campaign. Assigning a separate effect to pH, ionic strength, surface binding, or their interactions would require measurements designed to distinguish those influences. For sodium disilicate in particular, the favorable outcome also leaves open the original idea about binding through hydrogen bonds.

The search records how often and at what doses components were chosen over time. Those records reflect what the acquisition procedure proposed in light of earlier observations. Early recipes came from a different stage of knowledge than later ones, and several ingredients often changed together. The frequency of selection is therefore useful evidence about the behavior of the search. It does not function as a controlled estimate of how much activity each ingredient contributes in isolation. The strongest causal reading belongs to explicitly comparable recipes, while the campaign as a whole supports formulation-level conclusions and motivates more targeted chemistry.

The other checks address stability and repeatability

The baseline samples allowed the authors to monitor the apparatus with a constant recipe while testing new mixtures. This is a check on whether the workflow continues to produce comparable measurements over several days. It addresses an alternative explanation for an apparent improvement anywhere in a long campaign. If a fixed recipe changed substantially over time, changes in the experimental setup would need to be considered alongside changes in composition. The authors used the baseline for that purpose throughout the search.

The virtual runs address a different uncertainty. With different random starts and simulated measurements, the authors could ask whether the acquisition procedure repeatedly approached a high-performing region. Reaching 95% of the simulated maximum after around 160 experiments on average, across 100 searches, describes its behavior under that reconstruction of the problem. The exercise leaves open how the same procedure would compare with random sampling or another batch strategy under an equal experimental budget.

The navigation results also offer a direct engineering comparison. The authors measured the precision attained by map-based navigation and the precision attained when they added touch calibration. These measurements have clear roles in the workflow. The former indicates how well the robot could reach a bench, and the latter indicates the position it could establish relative to equipment before manipulating samples. This comparison shows why the authors used separate procedures for traveling through the room and carrying out a delicate task at a station.

Limitations

Limits the authors identify

The authors describe the optimizer as blind to the chemistry at the start of the search. Its ingredients had equal initial importance, and its predictions did not incorporate chemical theory or calculated physical properties. The method retained assumptions about similarity, smoothness, and measurement noise, and the researchers had already exercised chemical judgment in defining the space. The limitation concerns what the optimizer could infer or use once the search began. It could learn from observed activity and direct sampling accordingly. It could not use an independent account of chemical structure to give a promising but unexplored ingredient special weight.

Hypothesis formation also remained with the researchers. They chose effects worth investigating, selected additives that might reveal those effects, and later interpreted the pattern of results. The autonomous part began with a defined objective and a set of permitted changes to the recipe. A surprising result could change which experiments were selected. The system did not use that result to formulate a new chemical explanation, design a separate test of the mechanism, or choose a different class of candidate materials.

The authors propose combining future searches with computed structures or properties. A prior preference informed by those calculations could direct experiments toward components more likely to achieve the desired outcome. The prospect matters most when the number of ingredients grows and an undirected combinatorial search becomes less efficient. In their view, changing the algorithm should make spaces of at least 20 components, and potentially larger ones, tractable. That is a projection. The physical campaign demonstrated a 10-variable search within the constraints of this particular assay.

The paper also acknowledges the time needed to make the workflow usable. Development took approximately 2 years. The authors expect a shorter deployment elsewhere because core software and protocols could transfer. The experiment establishes that the completed platform could run the demonstrated work with little dedicated researcher time. A new laboratory would still have to integrate its stations, arrange the robot's access to them, and establish reliable sample handling and measurement before it could realize a comparable unattended workflow.

Limits of what the experiments establish

The highest activity reported was the highest observed in the campaign. The search tested a fraction of the defined simplex, so the available measurements cannot establish a global experimental optimum. There could be a stronger recipe among points the robot did not visit. The virtual maximum has a different status because it belongs to a fitted response surface. The association between that surface and the real chemistry depends on the original observations, the regression assumptions, and the noise used for the simulation. Reaching a target relative to the virtual maximum supports the simulation analysis without certifying completeness of the physical search.

The recurring baseline provides an uncertainty alongside its reported rate, and the screening comparisons also give uncertainties. The reported value of 21.05 µmol h⁻¹ identifies the peak observed during the search. The paper does not present a corresponding repeatability estimate alongside that peak. To interpret the headline comparison, it helps to distinguish the best observed vial from an independently repeated estimate of the best recipe's typical performance. A long search can select a recipe because its underlying activity is high and because a particular measurement of it happened to be favorable. The observed maximum alone cannot separate those effects.

The rate optimized during the formulation campaign was per vial per hour, and photocatalyst loading itself was adjustable. This is suitable for asking which of the permitted recipes yields the most hydrogen under the assay conditions. A claim about intrinsic activity per mass of catalyst would require a comparison expressed on that basis. The screening result for triethanolamine is also reported per catalyst mass, and its comparison with cysteine was made at a particular scavenger mass concentration. The paper's sixfold claim uses the cysteine baseline in the formulation campaign. It does not quantify the best recipe's advantage or disadvantage against a separately optimized triethanolamine formulation.

The measured conversion from cysteine to cystine establishes the oxidation product identified in the study. Demonstrating the proposed reversible shuttle would require evidence about regeneration and repeated operation. Similarly, measuring hydrogen from an illuminated sample with a hole scavenger establishes the reaction that was monitored. The work does not demonstrate a complete process that produces both hydrogen and oxygen from water while regenerating the scavenger.

The component histories give evidence about the recipes the optimizer actually visited. They leave several chemical explanations underdetermined. Adding an alkaline salt can change both pH and ionic strength, while changing multiple ingredients can also alter how a solid is dispersed or how other components associate with it. The paper's attribution of effects is useful within the composition campaign. Its evidence is less direct for a mechanism at the catalyst surface or for a claim that an ingredient has the same effect across every permitted background mixture.

Limits of the engineering and labor comparisons

The hardware demonstration involved a defined family of vial-based experiments with a specific sequence of operations. The mobile platform was built to provide reach, payload capacity, and access to multiple stations. Some instruments were used in their usual physical form, while station-specific reference cubes, a multipurpose gripper, and purpose-built equipment supported this workflow. Applying the architecture to another assay would depend on whether its samples and instruments can be handled with a similar sequence, or whether new handling and measurement hardware would be needed. The authors discuss adding instruments such as those for nuclear magnetic resonance or X-ray diffraction as possibilities.

The system's unattended operation was compatible with remote supervision. It could notify an operator about faults or depleted supplies, and the authors report that most errors could be reset remotely. The documented exclusions show why this distinction matters in a long run. Automation can flag a faulty sample and keep a bad measurement out of the search, but a chemical workflow still needs rules for identifying faults and arrangements for recovering from them. The paper's account describes how the project handled that operational problem while it ran.

Finally, the speed comparison comes from the authors' estimates of work time under manual, semi-automated, and autonomous procedures. It is not a controlled comparison in which three independently operated searches received the same inputs and were timed to the same chemical outcome. The 8-day run and the recorded instrument times give direct evidence about the deployed system. The manual and semi-automated figures explain the practical motivation and the expected reduction in labor. The magnitude of that reduction in another laboratory would depend on the assay, the equipment already available, and the amount of setup and intervention needed there.

What came after

The later citing works approach different parts of the problem raised by the mobile chemist. Some concern tool use or interactions with software interfaces. Others focus directly on chemistry, scientific discovery, or the evaluation of autonomous scientific work. Their subjects suggest several connections to the experiment. Citation establishes that they refer to the mobile chemist, while their stated topics show where the comparison is most natural.

A tool-learning perspective shifts attention to how a system chooses and uses external capabilities. In Burger and colleagues' experiment, choosing a composition and executing an instrument operation were separate tasks. The optimizer proposed a recipe, and the workflow translated that recipe into physically meaningful actions. The study on tool learning approaches the wider problem named in its title through foundation systems. The relationship is at the level of tool use. The mobile chemist supplies a concrete example in which the tools have physical preconditions, act on samples, and return evidence that can influence a later decision. Tool Learning

A chemistry review provides a closer disciplinary setting. Burger and colleagues give an example of autonomy within an explicit chemical objective. The system could select conditions, execute a procedure, and continue searching as measurements came back. The review's focus on language-based systems and autonomous agents in chemistry broadens the setting in which that example can be read. One distinction the mobile chemist makes especially clear is the division between executing a chemical search and supplying the scientific judgment that defines or interprets it. A Review of Autonomous Agents in Chemistry

Work on graphical interfaces addresses a different way an autonomous agent can interact with tools. The mobile robot can grasp a sample rack and press an instrument button. A graphical-interface agent acts through controls presented in software. Both settings put an interface between the system's next decision and the function it needs, but the available actions and sources of error differ. For the mobile chemist, successful interaction can depend on reaching the right place or properly seating a vial. The later work's stated focus is automated interaction with graphical user interfaces. UI-TARS

A work on automated scientific discovery places equation discovery and autonomous discovery systems within the same discussion. This offers a broader setting for interpreting what the mobile chemist discovered. The robot found an improved combination of ingredients through measurements it helped make. The authors supplied the chemical hypotheses and interpreted the resulting patterns. Equation discovery concerns another kind of scientific output, one that can express a relationship in symbolic form. The title of the later work spans those different kinds of automation, making the distinction between finding a useful experimental setting and producing an explanation especially relevant. Automated Scientific Discovery

The later work on realistic scientific workflows makes evaluation its central subject. The mobile chemist offers a case where the measures of success came from actual operations. A recipe had to be made, a measurement had to pass the workflow's checks, and the returned result had to help direct a later batch. Its engineering results also show why evaluating an isolated decision gives only part of the picture. The timing of an instrument, a failed seal, or a position error can affect whether a scientifically sensible choice yields a usable result. ScienceBoard addresses the evaluation of multimodal autonomous agents in scientific workflows, a related question about how to assess performance across the steps of a task. ScienceBoard

A historical and forward-looking account of AI scientists cites the mobile chemist in a wider discussion of automated research. The case helps give the term scientist a concrete scope. The system maintained a cycle of experimental choice and measurement, including preparation, reaction, analysis, and revision of the search. Its decisions were anchored to a target the researchers chose. The paper explicitly leaves hypothesis formation and chemical explanation to people. Those responsibilities matter when comparing a system that autonomously optimizes a formulation with accounts of more general scientific autonomy. The Past and Future of AI Scientists

Procedural reasoning in experimental chemistry is the subject of ChemReason-Bench. The mobile chemist illustrates how much procedural information can be supplied in advance even for a sophisticated autonomous run. The workflow already encoded the order of dispensing, sealing, optional dispersion, illumination, and analysis. It also encoded which conditions made a measurement unusable. The optimizer's freedom lay in the experimental settings it could propose within that procedure. A benchmark focused on procedural reasoning addresses the related ability to deal with the procedure itself. Taken together, the subjects show how autonomous experimentation can depend both on selecting informative conditions and on understanding the operations that make their results interpretable. ChemReason-Bench

Cite

Cite as Benjamin Burger, Phillip M. Maffettone, Vladimir V. Gusev, Catherine M. Aitchison, Yang Bai, Xiaoyan Wang, Xiaobo Li, Ben M. Alston, Buyi Li, Rob Clowes, Nicola Rankin, Brandon Harris, Reiner Sebastian Sprick and Andrew Ian Cooper. 2020. A mobile robotic chemist. Nature.

The paper itself, not this page. BibTeX from the library's record of the work. DOI 10.1038/s41586-020-2442-2

@inproceedings{burger2020mobile,
  title = {{A mobile robotic chemist}},
  author = {Benjamin Burger, Phillip M. Maffettone, Vladimir V. Gusev, Catherine M. Aitchison, Yang Bai, Xiaoyan Wang, Xiaobo Li, Ben M. Alston, Buyi Li, Rob Clowes, Nicola Rankin, Brandon Harris, Reiner Sebastian Sprick and Andrew Ian Cooper},
  booktitle = {Nature},
  year = {2020},
  doi = {10.1038/s41586-020-2442-2},
  url = {https://doi.org/10.1038/s41586-020-2442-2}
}