Recurrent Fully Convolutional Neural Networks for Multi-slice MRI Cardiac Segmentation

Paper · 2017 · Rudra P. K. Poudel, Pablo Lamata and Giovanni Montana

Summary

Drawing the inner boundary of the heart’s left ventricle in magnetic resonance images is difficult when that boundary is faint or the visible cavity is small. Yet those outlines support measurements used to assess cardiac structure and function. This paper investigates whether an automatic segmentation system can make better decisions by reading an ordered stack of images together. Its central proposal is a recurrent fully convolutional network, or RFCN: an architecture that combines detailed image analysis with a memory carried from one anatomical slice to the next.

The task concerns short-axis cardiac MRI. At a particular phase of the heartbeat, a stack of slices runs from the base of the heart towards its apex. Earlier slices can contain a relatively large ventricular cavity with a clear outline, while later slices can show a smaller region with weaker boundaries. Processing each image independently discards that progression. RFCN instead extracts features from each slice, updates a recurrent internal state, and uses the resulting features to predict which pixels belong to the left ventricle. The recurrence follows position through the heart rather than movement through time.

The architecture also simplifies the segmentation workflow. Several earlier approaches described by the authors first located the ventricle, then segmented a cropped region, and finally adjusted its boundary with a separate refinement procedure. RFCN learns localisation and segmentation together from complete short-axis slices. A contracting path gathers contextual information, a convolutional gated recurrent unit carries information between slices, and an expanding path restores spatial detail. Connections between corresponding stages help the output retain boundary information that would otherwise be lost during compression.

The experiments use the MICCAI cardiac segmentation benchmark and an independent PRETERM cohort. On MICCAI, the authors report an average perpendicular contour distance of 2.05 mm for RFCN, alongside overlap performance comparable to earlier approaches. On PRETERM, its reported contour distance is 1.56 mm, and it has the strongest Dice and contour-distance results among the tested architectures. Regional comparisons support the intended benefit near the apex, although the gain is not universal: the independent-slice fully convolutional network performs better around the base on MICCAI. Comparisons involving recurrent deep belief networks provide additional, though less direct, evidence that neighbouring slices contain useful information.

The paper therefore supports a practical architectural claim: information from preceding anatomical slices can improve automatic ventricular boundary tracing. It does not establish that recurrence is the best possible way to use a volume, that every anatomical region benefits, or that the system is ready for real-time clinical use. The authors propose bidirectional processing, volumetric convolutions, and joint handling of cardiac phases as future investigations. Their results concern endocardial segmentation, instead of a demonstrated improvement in diagnosis or in the final clinical measurements derived from those contours.

Interesting ideas

Put memory where representations are compact

RFCN introduces recurrence after the contracting path has reduced each image to a smaller set of contextual features. This gives the memory mechanism a representation that already combines information over a broader image region, while avoiding recurrent processing of every original pixel. The reusable idea is to decide where sequential context belongs within a processing pipeline. When individual observations contain substantial local detail, a compact intermediate representation can be a useful place to combine evidence across observations. The paper demonstrates this arrangement for anatomical slices; applying it elsewhere would require checking that the compression preserves the information the sequence mechanism needs.

Use the natural order of the data

The stack has a meaningful direction: the ventricular appearance changes as the slices approach the apex. RFCN uses that order rather than treating the images as an unordered collection. Its memory can therefore represent a progression in anatomy, not merely an association between arbitrary neighbouring inputs. This idea applies whenever observations arrive with a meaningful structural order. The important condition is that the ordering should explain something about the target. The experiments support the usefulness of the base-to-apex sequence, but they do not compare every alternative ordering or show that this direction is optimal.

Keep local detail alongside global context

Compression helps an architecture recognise a structure, but it can weaken the precise boundary information needed to outline that structure. RFCN addresses this tension by bringing higher-resolution features from the contracting path into the expanding path. The decoder receives both the recurrent contextual representation and spatial detail from the current slice. The broader lesson is that contextual reasoning and precise localisation need not compete for a single representation. A system can retain a detailed route alongside a more abstract route and combine them when producing its output.

Replace a handoff with a shared objective

The paper’s convolutional architectures process full slices and learn to find and segment the ventricle within the same network. Earlier pipelines described in the paper delegated localisation, segmentation, and refinement to separate components. Combining the first tasks removes an explicit handoff in which an imperfect crop can constrain everything that follows. This is a useful engineering pattern when several stages serve the same final objective and can share evidence. Its value should be assessed at the level of the complete task: a simpler workflow is attractive, but it still needs to preserve the accuracy that justified the separate stages.

Check a hypothesis in another architecture

The authors do not rely entirely on the FCN–RFCN comparison to argue that slice dependence matters. They also compare a deep belief network with a recurrent counterpart. These architectures use information differently, so agreement between the comparisons makes the contextual explanation more plausible. The transferable research habit is to test an idea through more than one implementation when possible. Such agreement strengthens an interpretation without removing the need for careful controls, because each implementation may also introduce its own changes in optimisation, capacity, or input requirements.

Inspect the regions the hypothesis concerns

An overall segmentation score can obscure where an architectural change helps. The authors therefore examine the base, central region, and apex separately. This analysis is closely tied to their motivation: the apex is where boundaries become particularly difficult to identify. It also reveals a qualification that an aggregate result could hide, because recurrence does not improve every region on every dataset. For other applications, the reusable practice is to define evaluations around the expected failure mechanism, while retaining the aggregate measure needed to judge overall performance.

Deep dive: Recurrent Fully Convolutional Neural Networks for Multi-slice MRI Cardiac Segmentation

How recurrent fully convolutional networks use neighbouring MRI slices to segment the left ventricle, with results and limits of the evidence. · about 34 minutes to read

How Mova uses it

For Mova, a small transparent language system written in Rust, the relevant connection is a design principle instead of an established implementation. The paper concerns cardiac images, and it supplies no evidence that RFCN has been incorporated into Mova. Its segmentation scores cannot be transferred into claims about language processing. What it offers is a concrete example of combining a representation of the current input with state accumulated from an ordered context.

A possible Mova experiment would separate the evidence available in the current text unit from information carried across earlier units. The analogue of the independent-slice baseline would process each unit without that carried state. A contextual version would receive the same current-unit evidence together with a representation of preceding material. The question would be whether the additional context resolves cases that remain ambiguous locally. This is a proposed experimental structure, not a claim that an image-segmentation architecture can simply be reused unchanged.

The placement of memory is also relevant. RFCN first computes visual features and then updates its recurrent representation. For Mova, the corresponding design question would be which representation should cross a unit boundary. Passing all raw input forward, passing a compact representation, and passing an explicitly selected set of facts would create different systems. The paper supports examining this choice deliberately. It does not establish which representation would be suitable for a transparent language system.

Transparency introduces a further distinction. RFCN’s internal memory is learned numerical state; the paper does not present it as an explanation that a reader can inspect directly. Mova could borrow the separation between local evidence and accumulated context while making the latter explicit enough to examine. For instance, an experimental implementation could expose what contextual information was available for a decision and compare the decision with the independent baseline. That would be an adaptation motivated by Mova’s transparency goal, rather than a property demonstrated by RFCN.

The paper’s evaluation strategy is more directly reusable than its visual operations. A Mova experiment could ask where contextual state helps, where it hurts, and whether the same pattern appears across different collections of text. The cardiac study’s regional analysis is valuable because it connects the measurement to a stated source of ambiguity. A corresponding language evaluation would need to define its own difficult cases from the task being studied, rather than borrowing anatomical categories.

Finally, the paper suggests restraint about architectural explanations. Its recurrent convolutional system differs from its baseline in training as well as in its use of memory. A Mova investigation could make the evidence easier to interpret by keeping the surrounding procedure comparable and documenting any unavoidable differences. Until such an experiment exists, the honest connection is that RFCN supplies a hypothesis about structured context and an example of how to investigate it. It does not supply a validated Mova component or a result about language.

The problem and its context

Why ventricular boundaries matter

Cardiac MRI gives physicians images from which they can estimate the heart’s structure and function. The paper names ventricular volume and ejection fraction as examples of relevant measurements. To obtain such measurements automatically, a system must identify the anatomical region consistently across the images that describe it. Here, the target is the endocardial boundary of the left ventricle: the outline separating its interior from the surrounding image.

This segmentation task is a form of machine learning in which the desired output is spatially dense. Instead of assigning a label to an entire examination, the system assigns image locations to the ventricular region or the background. The manual contours drawn by expert readers provide the reference against which the automatic result is evaluated.

The authors motivate automation in part by the repetitive work involved in assessment. A reliable automatic segmentation could reduce the mechanical portion of a radiologist’s task and support the estimation of clinically relevant parameters. That motivation explains why the workflow matters as well as the boundary score. A method that needs a person or another procedure to identify the target region has a different operational role from one that starts with the full image.

The paper does not, however, evaluate all the downstream steps implied by that motivation. Its experiments stop at segmentation quality. The distinction matters because a good anatomical outline is an input to clinical measurement, not evidence by itself that diagnosis becomes earlier or disease management improves.

Why a single slice can be ambiguous

The ventricular shape changes across the short-axis stack. It also varies between cardiac phases, patients, and scanning equipment. Accordingly, the system cannot solve the task by looking for a fixed shape at a fixed position. It needs to recognise a structure whose size and appearance depend on where the image lies within the heart and when it was acquired.

Some difficulties arise at the boundary itself. The authors identify blood flow, papillary muscles, and trabeculations as sources of weak or confusing visual evidence. An image can therefore contain the correct target without presenting a clean, high-contrast edge around it. The task is to infer a useful contour from appearance that may be incomplete or locally misleading.

The apex makes this problem especially clear. Toward that end of the stack, the visible ventricular region becomes smaller and its boundary can be less distinct. A decision based only on the current image may be uncertain even when the preceding slices establish a coherent anatomical progression. The paper’s central hypothesis is that this progression can help resolve local ambiguity.

This is a spatial sequence, not a temporal sequence. A stack at end diastole or end systole contains images from different positions at the same cardiac phase. RFCN’s recurrent step follows that positional sequence. Although the data are CINE MRI acquisitions, the proposed recurrence does not traverse the full heartbeat. Confusing these axes would misstate both the method and the scope of its evidence.

Earlier contour-based approaches

The authors organise previous segmentation methods into contour-based approaches, learned approaches, and hybrids. In an active contour approach, a candidate boundary is adjusted by minimising an energy function. Different terms encourage desirable properties of the boundary and agreement with the image.

The internal constraints express properties such as smoothness and continuity. The external constraints express information about appearance or the target’s shape. This division is useful because a plausible contour must satisfy more than the brightness at an individual pixel. It should also behave like a coherent anatomical boundary.

The difficulty is specifying an energy function that remains appropriate across the sources of variation in cardiac MRI. A constraint strong enough to stabilise an unclear boundary can also resist a legitimate change in anatomy. The authors also note the importance of initialisation: the region chosen to start the procedure can affect the final segmentation.

Learned methods offer another way to encode appearance and shape, using examples instead of relying entirely on manually designed constraints. Their corresponding demand is an adequate collection of training cases. Hybrid approaches try to combine learned information with a contour-refinement mechanism. The paper presents RFCN against this background of competing ways to supply both image evidence and anatomical regularity.

Earlier learned pipelines

The prior systems discussed in detail split the workflow into separate stages. One approach used deep belief networks for localisation and segmentation-related shape information, followed by a level-set procedure. Another used a convolutional network to locate the ventricle, stacked autoencoders for segmentation, and a level-set stage for refinement.

These pipelines could produce strong results, but their organisation imposed several distinctions that RFCN sought to remove. They treated slices separately, used different components for locating and segmenting the target, and trained separate architectures for images around the base and apex. The latter decision acknowledged that local shape variation differs across the stack.

The recurrent proposal addresses the same heterogeneity through shared sequential processing. Rather than assigning the base and apex to separately trained systems, it lets the current representation depend on the preceding slices. The intended advantage is that one architecture can learn how ventricular appearance changes along the stack.

That intention should not be overstated. A recurrent architecture is not automatically a complete anatomical description. Its internal state is learned from segmentation supervision, and the paper evaluates it through the quality of its output. The claim is that the arrangement makes useful context available, not that the learned state has been shown to encode every relevant property of cardiac anatomy.

Why fully convolutional processing was a useful starting point

Fully convolutional networks supplied the other major ingredient. As described by the authors, an FCN converts an image into dense predictions through convolution, spatial reduction, and subsequent enlargement of its feature maps. This avoids applying an independent classifier to each possible image patch.

The contracting portion gathers increasingly broad context while reducing spatial dimensions. The expanding portion brings the representation back towards the resolution needed for segmentation. Such an architecture can use both the overall arrangement of the image and local evidence around a possible boundary.

The authors connect their design particularly closely to U-Net, whose expanding path retains substantial representational capacity and combines information from different resolutions. RFCN keeps this broad organisation and adds a recurrent component at its compressed contextual stage. The contribution is therefore an extension of an existing dense-prediction architecture to an ordered anatomical stack.

The paper also acknowledges independent work adapting recurrent fully convolutional processing to video segmentation. Its own application differs in what the sequence represents: spatial positions through cardiac anatomy rather than successive video frames. This acknowledgment helps locate the contribution accurately. The paper investigates a particular use of recurrent dense prediction, with evidence from ventricular segmentation, instead of claiming that recurrence and convolution had never previously been combined.

The method, step by step

Follow an anatomical stack through the network

The input is the complete sequence of short-axis images for a selected cardiac phase. Each image has a corresponding manually produced ventricular mask during training. The images within the sequence are assumed to have matching dimensions, and the outputs follow the same slice order.

The processing begins independently for each image, extracting visual features with convolution and pooling. At the most compressed stage, those features enter a convolutional recurrent unit together with the state from the preceding slice. The updated representation is then expanded into a segmentation for the current image. Higher-resolution features from that same image supply local detail during expansion.

From an ordered cardiac stack to ventricular masks

The steps in order.

From an ordered cardiac stack to ventricular masksStep 1: Read slices from base towards apex1. Read slices from base towards apexStep 2: Extract features from each slice2. Extract features from each sliceStep 3: Compress features through convolution and pooling3. Compress features through convolution and poolingStep 4: Update convolutional recurrent memory4. Update convolutional recurrent memoryStep 5: Upsample with detailed features from each slice5. Upsample with detailed features from each sliceStep 6: Predict ventricle and background for each pixel6. Predict ventricle and background for each pixel

The flow contains distinct routes for different kinds of information. The recurrent connection carries context across slices. The connections from the contracting path carry spatial detail within a slice. Both reach the final segmentation, but they address different weaknesses: missing anatomical context and lost boundary resolution.

Define the sequence and its state

The paper indexes the slices as follows:

s ∈ {1, …, S}

Here, s identifies a particular slice, and S is the sequence length for the selected cardiac phase. The ordered set runs from the beginning of the stack to its end. In the proposed direction, this means moving from the base toward the apex.

After the initial feature-extraction path and the first convolution in the global component, the current slice is represented by eₛ. The recurrent transformation is:

hₛ = φ(hₛ₋₁, eₛ)

The symbol hₛ denotes the updated hidden representation for slice s. The term hₛ₋₁ is the hidden representation passed forward from the preceding slice. The input eₛ contains the current slice’s compressed features, and φ denotes the nonlinear recurrent operation.

This expression states the method’s essential dependency. The contextual representation for the current image is determined jointly by current evidence and carried state. It does not require the current image to be understandable in isolation. Conversely, the state does not replace current evidence; both are inputs to the update.

The initial state, h₀, is learned during training. It supplies the recurrent input needed before the first slice has been processed. This is a shared learned starting representation, instead of a state obtained from a preceding image outside the stack. The paper does not describe giving the network a patient-specific initial state or an externally supplied anatomical measurement.

The dimensions of hₛ match those of eₛ. In the described global component, the compressed representation has the following shape:

256 × 30 × 30

The value 256 is the number of feature channels. The values 30 and 30 describe the spatial dimensions of each feature map. These are internal representations, not the dimensions of an original MRI slice or a predicted anatomical region.

Extract features while reducing spatial size

The contracting path repeatedly applies local convolutions and max pooling. A convolution learns how to combine nearby values into a feature response. Max pooling reduces spatial size while retaining strong responses within the pooling region. Repetition gives later layers a representation that is less tied to individual image pixels.

The described blocks contain a pair of convolutional layers using 3 × 3 filters and stride 1, together with rectified linear activation and max pooling. The pooling operation uses a 2 × 2 window with stride 2. A rectified linear unit, abbreviated ReLU, supplies the nonlinear activation used in these blocks.

The authors increase the number of feature channels as spatial dimensions shrink. Their stated change in tensor shape is:

c × h × w → 2c × h/2 × w/2

The symbol c is the number of input feature channels, while h and w are their height and width. On the right, 2c indicates the increased channel count. The expressions h/2 and w/2 indicate the reduced spatial dimensions. The arrow describes the input-to-output transformation of a contracting block.

This arrangement trades spatial resolution for a richer set of features. An output location can draw on a broader portion of the original image after successive reductions. That is useful for deciding whether a region belongs to the ventricle, because local appearance alone may resemble other structures.

The contraction also creates a problem that the expanding path must address. A compressed feature map cannot directly provide a detailed outline at the original resolution. Information about where a boundary lies may be weakened even when information about the presence of the target is strengthened. RFCN therefore preserves connections to earlier, more detailed features.

Insert recurrence into the global component

At the end of the contracting path, the global component first applies a 3 × 3 convolution with stride 1 and a ReLU. Its output is the eₛ representation used in the recurrent equation. The convolutional recurrent unit then maps that representation and the previous state into hₛ.

The authors considered long short-term memory and gated recurrent units as ways to implement the recurrent operation. Their stated concern is the difficulty of training ordinary recurrent structures when gradients diminish during propagation. Gated mechanisms are intended to make the management of sequential information more effective.

They choose a gated recurrent unit, or GRU, in convolutional form. The paper cites prior evidence that GRUs can achieve performance comparable to long short-term memory while requiring fewer parameters and less memory. This is a justification drawn from earlier work, instead of a comparison performed in the cardiac experiments.

The convolutional form is important to the architecture. A conventional non-convolutional recurrent mapping would not preserve the spatial organisation of feature maps in the same way. By using convolutional operations within the recurrent component, the design retains local spatial relationships and reduces the parameter burden relative to its non-convolutional counterpart, according to the authors.

The paper specifies the general recurrence but does not present the internal gate equations. Its methodological description therefore supports an explanation of the state transition and its role, without supplying a complete algebraic account of the GRU implementation. There is no reported cardiac comparison between different gate formulations.

After the recurrent operation, another 3 × 3 convolution with stride 1 and a ReLU completes the global component. The resulting features are then passed into the expanding path. The memory contribution is consequently integrated with further visual processing before the final pixel predictions are produced.

Recover resolution without losing the boundary

The expanding path repeatedly enlarges the feature maps. The authors describe a convolution with fractional stride 1/2, followed by concatenation with a corresponding feature map from the contracting path. Further 3 × 3 convolutions and ReLU activation process the combined representation.

Its stated change in feature shape is:

c × h × w → c/2 × 2h × 2w

Here, c, h, and w again denote channel count, height, and width at the block input. The output has c/2 channels and spatial dimensions 2h and 2w. The expression describes the reversal of the contraction’s broad pattern: spatial detail is restored while the channel count decreases.

Concatenation means that the enlarging representation and a higher-resolution representation are supplied together to later operations. The earlier features are aligned with the corresponding level of the contracting path. They provide information tied more closely to the current image’s local structure.

This is especially relevant to segmentation because simply enlarging a coarse representation can smooth an object’s outline. The authors explicitly identify that smoothing as a concern. Bringing detailed features back into the process gives the output a better opportunity to follow the actual boundary instead of a coarse approximation.

These within-slice connections also clarify what RFCN asks recurrence to accomplish. The memory does not need to carry every detail of the current boundary. Local detail remains available through the contracting-to-expanding connections. The recurrent component can contribute broader context about the anatomical progression while the local route helps place the contour precisely.

Convert features into a mask

A final 1 × 1 convolution maps the expanded representation to the target classes: ventricular region and background. The softmax operation supplies class probabilities at the image locations. The resulting dense output assigns the segmentation across the slice.

The 1 × 1 operation changes how the feature channels are combined at each spatial position. At this stage, the larger receptive processing has already occurred in the preceding architecture. The last operation translates that accumulated representation into the classes required by the task.

The network learns from the manually defined masks using cross-entropy. This objective rewards assigning higher probability to the reference class at each location. The paper names the objective but does not provide its explicit formula, so no additional loss expression is needed to describe the reported method.

Localisation is implicit in this dense prediction task. The system starts with the complete slice and must place the ventricular region correctly within it. It does not receive a target-centred crop as its required input. That distinction is central to the comparison with the belief-network baselines.

Train the convolutional architectures

The independent-slice FCN is trained with stochastic gradient descent and momentum. RFCN uses stochastic gradient descent with RMSProp. Gradients are computed by back-propagation, including through the recurrent component, so the segmentation objective trains the operations that produce and use the carried state.

RFCN begins from weights learned by FCN. The authors report that this provides useful starting weights and reduces training time. It is an important detail because the recurrent architecture is not trained solely from an unrelated random initialisation in the reported procedure. Its starting point already contains a solution to the independent-image segmentation task.

Batch normalisation is added within the blocks after convolutional processing, with the placement described relative to the pooling and upsampling operations. This is part of the training architecture rather than a separate boundary-refinement stage. The complete convolutional system remains trained against the segmentation objective.

The reported settings include a learning rate of 0.01, decay of 3% after an epoch, momentum of 0.9, and weight decay of 0.00005. These are training hyper-parameters, not properties of the MRI acquisition. The paper presents them as the settings associated with the strongest results across its investigated architectures.

The authors also augment the training data. Images are translated within ±16 pixels and rotated within ±40°. These transformations create additional training examples intended to reduce overfitting. They are applied in the training procedure for both datasets, rather than being described as a way to combine predictions during evaluation.

Each reported result is the best obtained across 5 experiments with random initial parameters. This reporting choice gives a sense of the search over initialisation but does not describe the distribution of outcomes. Without the scores from the other runs, the reader cannot determine how sensitive an architecture was to its starting parameters.

Build a second test of slice dependence

The authors also investigate deep belief networks, abbreviated DBNs. Their building blocks are restricted Boltzmann machines, which are trained here using contrast divergence. Dropout is reported to improve the performance of these architectures.

For the recurrent alternative, recurrent restricted Boltzmann machines are stacked into a recurrent deep belief network, or RDBN. The recurrence uses additional bias information to make the output depend on the ordered sequence. The authors adopt this architecture to ask whether the value of slice context extends beyond the fully convolutional design.

The DBN and RDBN comparisons have a different input condition from FCN and RFCN. They receive a region already centred on the left ventricle. As a result, their task omits the requirement to locate the target within the full slice. This gives them an advantage in the information supplied at input, while limiting direct comparisons of complete workflow performance.

The recurrent belief-network experiment is therefore most informative when read as a comparison within that family. If RDBN improves on DBN while both receive focused inputs, that supports the hypothesis that the sequence contains useful information even after localisation has been supplied. It does not establish that the recurrent mechanisms in RDBN and RFCN work identically.

Experiments and results

Read the evaluation as a segmentation study

The experiments compare predicted endocardial contours with expert-drawn references. They use Dice index, average perpendicular distance, and the proportion classified as good contours. Together, these measurements address related but distinct aspects of performance.

Dice describes overlap between the predicted ventricular region and the reference region. A higher value indicates better agreement. Average perpendicular distance, abbreviated APD, measures discrepancy between the predicted and manual contours in millimetres; lower values indicate closer boundaries. Good contours, abbreviated GC, reports a percentage associated with the benchmark’s contour-quality criterion.

The paper names GC and cites the earlier evaluation work, but it does not spell out the criterion in its methodological account. The percentage should therefore be read as the reported benchmark measure, without inventing a threshold or treating it as interchangeable with Dice. A method can behave differently under an overlap measure and a contour-based measure.

This distinction matters particularly near the apex. When the visible region is small, a boundary error can have a substantial effect on overlap. Conversely, aggregate overlap can be influenced heavily by larger regions elsewhere in the stack. The regional analysis is therefore needed to connect the main scores to the paper’s anatomical hypothesis.

The MICCAI dataset

The MICCAI 2009 challenge dataset contains 45 CINE MRI examinations. Each of its three subsets—training, validation, and online testing—contains 15 cases. Within each subset, the pathology categories comprise 4 cases with heart failure and infarction, 4 with heart failure without infarction, 4 with ventricular hypertrophy, and 3 healthy subjects.

These categories describe the collection, but the algorithms do not use the clinical labels as input. The segmentation system is trained and evaluated on images and contours. The paper consequently does not establish a disease-aware segmentation procedure or report separate accuracy for those clinical groups.

The acquisitions contain 20 phases of the cardiac cycle, while the contour supervision used here concerns end diastole and end systole. A typical selected phase contains 6–12 short-axis slices. Within a subset, the selected phases produce 30 sequences, and the reported average sequence length is 8.94 slices.

The acquisition description gives an 8 mm slice thickness and an 8 mm gap between slices. The field of view is 320 mm × 320 mm, and the image matrix is 256 × 256. These details matter because the recurrent input is an ordered set of separated images, instead of a densely continuous anatomical volume.

The reference contours were drawn by a cardiologist and checked independently by another reader. They provide an expert reference for evaluating the automatic segmentation. The paper does not report inter-reader variation as an additional benchmark against which to judge the size of the automatic contour discrepancy.

An unusual but explicit evaluation choice concerns the subset names. The authors use the online set for validation and report their MICCAI results on the subset named validation. This arrangement is intended to maintain comparability with earlier studies. The reported results should be understood under that actual procedure, instead of assuming that the conventional label of a subset fully describes its role.

MICCAI comparisons

The paper reports earlier DBN-based performance with Dice 0.88, GC 95.71%, and APD 2.34 mm. It also reports an earlier convolutional-localisation and autoencoder-segmentation pipeline with Dice 0.90, GC 90%, and APD 2.84 mm before its additional post-processing.

FCN and RFCN are described as achieving comparable overlap performance while producing stronger good-contour results and smaller contour distances. The explicitly stated RFCN APD is 2.05 mm. The authors also report that RFCN improves on their FCN baseline in contour distance.

MICCAI validation-set average perpendicular contour distance

RFCN has the smallest reported contour distance among these comparisons.

MICCAI validation-set average perpendicular contour distanceEarlier DBN-based approach: 2.34Earlier DBN-based approach2.34Earlier autoencoder pipeline before post-processing: 2.84Earlier autoencoder pipeline beforepost-processing2.84RFCN (this paper): 2.05RFCN (this paper)2.05
The numbers
System or settingAPD, mm
Earlier DBN-based approach2.34
Earlier autoencoder pipeline before post-processing2.84
RFCN (this paper)2.05

The chart compares the numerical contour-distance results discussed in the paper, but the workflow conditions remain important. In particular, the autoencoder pipeline’s value is explicitly from before its subsequent refinement. The paper also distinguishes published results after level-set post-processing when presenting its broader comparison.

The overlap and distance findings should not be collapsed into a claim that RFCN is uniformly superior under every measure. The text describes its Dice as comparable to earlier results. Its more distinctive reported advantage concerns contour quality and the use of a unified architecture.

Nor does the 2.05 mm value alone explain why the gain occurs. It establishes a measured output difference under the evaluation procedure. The interpretation that neighbouring slices help is supported by the architecture comparison and regional analysis, while remaining subject to the training differences between FCN and RFCN.

The PRETERM dataset

The independent cohort contains 234 subjects aged 20 to 39. Of these, 102 were followed after preterm birth, and 132 were born at term following uncomplicated pregnancies. The collection was originally used to investigate how perinatal factors relate to ventricular characteristics.

The imaging used a 1.5-T Siemens Sonata scanner. The acquisitions have 7 mm slice thickness and a 3 mm gap. Their reported in-plane resolution is 1.43 ± 0.29 mm, with a minimum of 0.57 and a maximum of 2.17. The images and masks were resampled to 2 mm in-plane resolution, producing image dimensions of 212 × 212.

An expert reader traced the endocardial borders at end systole and end diastole using the named Siemens Argus software. The data were randomly divided into a training set of 194 subjects, a validation set of 20, and a testing set of 20.

The authors apply the same architectural designs to this cohort without further architectural customisation. This is an independent application of the approach, but it is not evidence that weights learned on MICCAI were used unchanged on PRETERM. The described evaluation involves training and assessing the architectures within the dataset procedure.

PRETERM comparisons

The PRETERM experiments compare FCN, RFCN, DBN, and RDBN. The belief-network architectures receive focused regions containing the ventricle, whereas the convolutional architectures process complete slices. The authors were unable to evaluate the earlier multistage autoencoder pipeline on this cohort.

RFCN has the strongest reported Dice and APD performance among these alternatives. Its APD is 1.56 mm. For comparison, DBN receives the target location through its input region but has APD 2.05 mm.

PRETERM average perpendicular contour distance

RFCN achieves a closer contour despite starting from complete slices.

PRETERM average perpendicular contour distanceDBN with supplied ventricular region: 2.05DBN with supplied ventricular region2.05RFCN (this paper): 1.56RFCN (this paper)1.56
The numbers
System or settingAPD, mm
DBN with supplied ventricular region2.05
RFCN (this paper)1.56

This comparison supports the practical usefulness of the fully convolutional approach. The result does not depend on giving RFCN a manually focused target region. Its architecture handles the full-image localisation requirement together with segmentation.

Within the belief-network family, RDBN improves on DBN in good contours and APD. The regional discussion also reports better performance for the recurrent version across cardiac locations. That pattern supplies additional evidence for the usefulness of information spanning slices.

The paper does not claim that recurrence removes the performance gap between belief networks and the convolutional architectures. On PRETERM, the latter remain stronger overall despite facing the broader input problem. The results support both the choice of a fully convolutional foundation and the addition of sequential context.

What the anatomical breakdown adds

The authors examine regions defined by their positions within the stack. Base-1, Base-2, and Base-3 refer to groups extending inward from the base, while the analogous apex groups extend inward from the opposite end. Remaining slices form the central region.

For this analysis, Dice is calculated by pooling the relevant pixels across samples. The regional score is therefore not described as the arithmetic mean of independently calculated case scores. That aggregation choice matters when interpreting what “better near the apex” means.

RFCN outperforms FCN in the central and apical regions on both datasets. On MICCAI, however, FCN is better near the base. This result gives the paper’s main interpretation both support and a boundary: sequential context is useful in the regions emphasised by the hypothesis, but its benefit is not anatomically uniform.

The authors highlight a further difference between the cohorts. For the most apical slice, RFCN has Dice 0.85 on MICCAI and 0.76 on PRETERM. They regard this as unexpected because they had anticipated that the more regular PRETERM cohort would be especially favourable to exploiting relationships between slices.

Those values describe different datasets, so they are not a controlled experiment on cohort regularity. They identify a result that the proposed explanation does not fully account for. The paper explicitly leaves its explanation for further investigation.

The visual examples are consistent with the quantitative interpretation: RFCN can follow boundaries that FCN handles less accurately when local contrast is weak. Such examples help explain the kind of improvement being discussed. They do not establish how often that behaviour occurs beyond the aggregate and regional measurements.

What the ablations show

Recurrence is tested through architecture comparisons

The paper offers comparisons between recurrent and independent processing, along with regional analysis, rather than an extensive component-by-component ablation programme. Its closest test of the central mechanism is the comparison between FCN and RFCN.

These architectures share the fully convolutional approach to dense segmentation. RFCN adds a state that connects successive slices at the compressed feature stage. Better performance for RFCN is therefore consistent with the proposition that anatomical context contributes useful information beyond the current image.

The regional pattern is particularly informative. If the proposed benefit is help with weak local evidence, an improvement around the apex fits that account more closely than an undifferentiated gain would. The result near the MICCAI base also prevents the explanation from becoming too broad. The state helps in important circumstances, but it can coexist with poorer performance elsewhere.

This is not a perfectly isolated intervention. FCN and RFCN use different optimisation procedures, and RFCN is initialised from FCN weights. Adding recurrence also changes the architecture’s capacity. The reported comparison evaluates the complete trained systems under the authors’ procedure, rather than estimating the effect of context while holding every other influence fixed.

The belief-network comparison supports the broader hypothesis

DBN and RDBN provide another way to examine dependence across slices. Their comparison matters because recurrent context is introduced through a different architectural mechanism. Improvements in RDBN therefore make it less plausible that the entire pattern is an accident of the particular convolutional decoder.

On PRETERM, the recurrent belief network has better good-contour and contour-distance results than its independent counterpart. The regional analysis describes improvements across cardiac locations. These findings agree with the general proposition that a stack contains useful information beyond separately viewed slices.

The input condition narrows the interpretation. Both belief-network alternatives receive an already localised region. Their recurrent advantage therefore concerns segmentation after location has been supplied. It does not demonstrate an equivalent advantage for full-image detection.

The comparison also does not identify what information the recurrent units use. They may exploit regular changes in size, position, appearance, or a combination of these. The paper evaluates the resulting contours, not a decomposition of the hidden representation into named anatomical properties.

Regional analysis tests where the advantage appears

The breakdown by position is an analysis of the proposed mechanism rather than an architectural ablation. It asks whether the gains occur in the difficult parts of the anatomy that motivated the method.

The apical improvement supports that connection. The central improvement indicates that the benefit is not restricted to the final edge of the stack. The MICCAI basal result shows that the system’s additional context can have uneven consequences across regions.

The unexpected MICCAI–PRETERM apical ordering is equally valuable. It indicates that having an apparently more homogeneous cohort does not, on its own, explain the recurrent system’s performance. A satisfactory account would need to examine other properties of the images, supervision, and training, but the paper does not establish which of those is responsible.

Several design choices remain unseparated

The authors report that translation and rotation augmentation improved performance, but they do not present a detailed numerical comparison isolating each transformation. Their statement supports the use of augmentation in the reported procedure, not a precise estimate of its individual contribution.

Likewise, the choice of a convolutional GRU is motivated by spatial organisation and parameter efficiency, without a cardiac experiment comparing it directly with a non-convolutional GRU or a long short-term memory component. The arguments explain the design, while the experiments evaluate the selected design.

There is no reported removal study for the high-resolution connections, no comparison of alternative locations for recurrence, and no completed comparison with volumetric convolutions. The results therefore support the whole RFCN arrangement more strongly than they rank its internal choices. Keeping that distinction clear preserves the paper’s contribution without asking the evidence to answer questions it did not test.

Limitations

Limits the authors explicitly identify

The authors directly acknowledge that the apical result differs from their expectation across datasets. RFCN performs better on the most apical MICCAI slice than on the corresponding PRETERM category, despite their expectation that PRETERM’s relative regularity would favour recurrent processing. They do not resolve the discrepancy.

This matters because the main explanation is anatomical continuity. The result does not contradict that explanation outright, but it shows that continuity alone is insufficient to predict performance. The benefit depends on the data and on how the learned system interacts with them.

The proposed future directions also make several boundaries explicit. The architecture reads from base toward apex; an inverse path is left for future work. A bidirectional extension could make information from the opposite direction available, but the paper supplies no result for such an extension.

Volumetric convolutions are another stated alternative for capturing relationships between slices. They are proposed as a future investigation, so the paper cannot establish whether recurrent processing is more accurate, more efficient, or more data-efficient than that alternative.

The handling of cardiac phases is also limited. The experiments use stacks at selected phases, and a temporal extension covering all phases is prospective. The recurrent connection demonstrated here should not be interpreted as a completed account of the full cardiac cycle.

Limits visible in the experimental design

The most direct comparison changes training along with architecture. RFCN uses RMSProp and begins from FCN weights, while FCN uses momentum-based stochastic gradient descent. Consequently, the observed difference belongs to the complete procedure. The evidence does not isolate how much of the gain comes from recurrent context, the starting weights, or the altered optimisation.

Reporting the best run from 5 experiments introduces another uncertainty. The selected values show what the authors achieved under those runs, but they do not describe typical performance or variability. An architecture that occasionally performs very well and one that performs consistently could receive similar presentation under this reporting rule.

The paper does not accompany the central comparisons with uncertainty estimates or a statistical significance analysis. This does not make the measured differences irrelevant. It limits how confidently their stability can be assessed, especially when comparing approaches evaluated through different published workflows.

Regional Dice also has a specific aggregation meaning. Pooling pixels across cases gives an overall regional overlap measure. It does not reveal the distribution of patient-level failures or whether the benefit is concentrated in particular examinations. A strong pooled score and reliable performance on every patient are different claims.

The datasets support independent evaluation, not unrestricted transfer

The study includes distinct image collections, which is stronger than evaluation on a single cohort. They differ in their subjects, acquisition characteristics, spacing, and processing. The same architectural design performs well in both applications.

However, that result does not establish unrestricted deployment across scanners or populations. The paper describes training and evaluation procedures for the datasets, not a test in which one trained system is frozen and transferred unchanged to every new setting. Architectural reuse and direct transfer of learned parameters should remain separate claims.

The clinical categories in MICCAI are not used as predictive inputs, and the paper does not provide a disease-specific performance analysis. Similarly, PRETERM’s cohort structure does not on its own establish equal performance for every subgroup. These are properties of the collections rather than demonstrated guarantees about the segmentation system.

The target is also narrow: the ventricular endocardium. Success here does not show equivalent performance on other cardiac structures or other organs. The transferable idea is a way to use ordered context; the numerical evidence remains attached to the task actually evaluated.

The baseline conditions differ

The belief-network baselines receive focused ventricular regions. FCN and RFCN receive complete slices. The authors correctly identify this difference, and it is relevant when interpreting their stronger convolutional results.

The arrangement gives the belief networks useful location information, but it also means the architectures are not evaluated under identical input conditions. The comparison answers a practical question about the tested workflows while providing a less direct answer about architecture alone.

Earlier published approaches introduce another distinction because some include separate level-set refinement. A pre-refinement score should not stand in for the final output of a pipeline that performs additional processing. The paper acknowledges these stages, and the comparisons need to retain that qualification.

The inability to test the earlier autoencoder-based pipeline on PRETERM leaves the independent-dataset baseline set narrower. RFCN performs best among the alternatives evaluated there; the paper does not establish a PRETERM ranking that includes an untested pipeline.

Computational promise exceeds the timing evidence

Combining localisation and segmentation removes explicit stages from the workflow. It is reasonable for the authors to regard this as an architectural and practical advantage. The system also avoids the sliding-window style of independent patch processing discussed in the paper.

Nevertheless, the study does not report the timing measurements needed to substantiate a particular real-time operating claim. There is no demonstrated latency target, acquisition-to-output timing study, or detailed computational comparison attached to the segmentation results.

The conclusion should therefore remain at the level of potential. The architecture may simplify implementation and reduce work associated with separate stages, but a claim about real-time use would require direct measurement under specified conditions.

Segmentation scores are not clinical outcomes

The study’s opening motivation includes better support for cardiac assessment. Its experiments evaluate anatomical masks and contours. It does not report whether the resulting volumes or ejection fractions improve by a measured amount, nor whether clinical decisions change.

Reference contours are also a benchmark, not an error-free account of anatomy. The paper describes expert drawing and checking, which makes them appropriate evaluation targets. Without an analysis of reader disagreement, however, the contour-distance values cannot be converted into a claim that the system has matched human variability.

Finally, the recurrent state is not directly validated as an interpretable anatomical representation. Better segmentation is evidence that the arrangement is useful. It does not reveal exactly what has been remembered, how that information is organised, or whether every decision relies on the intended anatomical progression.

What came after

No later citing studies are identified for tracing a documented line of follow-up work. The paper’s references establish its foundations and acknowledge related work, but they do not justify claims about subsequent adoption, later benchmark improvements, or the long-term influence of this particular RFCN.

The nearest related recurrent segmentation work discussed by the authors concerns video and is described as independent. It should therefore be understood as a neighbouring investigation, rather than as evidence that another group built on the cardiac study. The connection is methodological: recurrent state is inserted into a fully convolutional system that produces dense outputs.

The clearest forward path comes from the authors’ own proposals. Bidirectional processing would add access to the stack in the reverse anatomical direction. Volumetric convolutions would offer another way to combine information across slices. A temporal extension would add the relationships between cardiac phases to the spatial relationships already used.

Each proposal targets a specific boundary of the demonstrated system. Reverse processing addresses the fact that a forward state cannot use later slices when interpreting an earlier one. Volumetric processing would permit a comparison between recurrent accumulation and another representation of spatial context. Joint phase processing would move beyond separate stacks at end diastole and end systole.

These remain research directions in the paper. Their value is to make the next questions concrete without implying that the answers are already known. The established contribution is the tested architecture and its evidence: a unified detector and segmenter can use the ordered anatomy of an MRI stack to improve ventricular contours, particularly in regions where a single image supplies weak boundary evidence.

Cite

Cite as Rudra P. K. Poudel, Pablo Lamata and Giovanni Montana. 2017. Recurrent Fully Convolutional Neural Networks for Multi-slice MRI Cardiac Segmentation. Lecture notes in computer science.

The paper itself, not this page. BibTeX from the library's record of the work. DOI 10.1007/978-3-319-52280-7_8 · arXiv 1608.03974

@inproceedings{poudel2017recurrent,
  title = {{Recurrent Fully Convolutional Neural Networks for Multi-slice MRI Cardiac Segmentation}},
  author = {Rudra P. K. Poudel, Pablo Lamata and Giovanni Montana},
  booktitle = {Lecture notes in computer science},
  year = {2017},
  doi = {10.1007/978-3-319-52280-7\_8},
  eprint = {1608.03974},
  archivePrefix = {arXiv},
  url = {https://doi.org/10.1007/978-3-319-52280-7_8}
}

↑ back to top

This page in Markdown https://md.research.elamur.ai/free/en/papers/poudel-2017-recurrent-fully-convolutional-neural-networks/

References

25 references, from the paper's own bibliography.

  1. Avendi, M.R., Kheradvar, A., Jafarkhani, H.: A combined deep-learning and deformable-model approach to fully automatic segmentation of the left ventricle in cardiac MRI. Medical Image Analysis 30, 108–119 (May 2016) OpenAlex ↗ · Scholar ↗
  2. Cho, K., van Merrienboer, B., Gulcehre, C., Bahdanau, D., Bougares, F., Schwenk, H., Bengio, Y.: Learning Phrase Representations using RNN Encoder-Decoder for Statistical Machine Translation. arXiv:1406.1078 (2014) our card
  3. Chung, J., Gulcehre, C., Cho, K., Bengio, Y.: Empirical Evaluation of Gated Recurrent Neural Networks on Sequence Modeling. arXiv:1412.3555 (2014) OpenAlex ↗ · Scholar ↗
  4. Georgescu, B., Zhou, X.S., Comaniciu, D., Gupta, A.: Database-guided segmentation of anatomical structures with complex appearance. In: CVPR. vol. 2, pp. 429–436 (2005) OpenAlex ↗ · Scholar ↗
  5. Hinton, G.E., Salakhutdinov, R.R.: Reducing the Dimensionality of Data with Neural Networks. Science 313(5786), 504–507 (2006) OpenAlex ↗ · Scholar ↗
  6. Hinton, G.E., Srivastava, N., Krizhevsky, A., Sutskever, I., Salakhutdinov, R.R.: Improving neural networks by preventing co-adaptation of feature detectors. arXiv:1207.0580 [cs] (2012) our card
  7. Hochreiter, S., Schmidhuber, J.: Long Short-Term Memory. Neural Computation 9(8), 1735–1780 (1997) OpenAlex ↗ · Scholar ↗
  8. Hu, H., Liu, H., Gao, Z., Huang, L.: Hybrid segmentation of left ventricle in cardiac MRI using gaussian-mixture model and region restricted dynamic programming. Magnetic Resonance Imaging 31(4), 575–584 (2013) OpenAlex ↗ · Scholar ↗
  9. Huang, R., Pavlovic, V., Metaxas, D.N.: A graphical model framework for coupling MRFs and deformable models. vol. 2, pp. 739–746 (Jun 2004) OpenAlex ↗ · Scholar ↗
  10. Huang, S., Liu, J., Lee, L.C., Venkatesh, S.K., Teo, L.L.S., Au, C., Nowinski, W.L.: An image-based comprehensive approach for automatic segmentation of left ventricle from cardiac short axis cine MR images. Journal of Digital Imaging 24(4), 598–608 (2011) OpenAlex ↗ · Scholar ↗
  11. Ioffe, S., Szegedy, C.: Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift. arXiv:1502.03167 [cs] (Feb 2015) OpenAlex ↗ · Scholar ↗
  12. Jolly, M.: Fully Automatic Left Ventricle Segmentation in Cardiac Cine MR Images Using Registration and Minimum Surfaces. MIDAS Journal 49 (2009) OpenAlex ↗ · Scholar ↗
  13. Kass, M., Witkin, A., Terzopoulos, D.: Snakes: Active contour models. International Journal of Computer Vision 1(4), 321–331 (1988) OpenAlex ↗ · Scholar ↗
  14. Lewandowski, A.J., Augustine, D., Lamata, P., Davis, E.F., Lazdam, M., Francis, J., McCormick, K., Wilkinson, A.R., Singhal, A., Lucas, A., Smith, N.P., Neubauer, S., Leeson, P.: Preterm heart in adult life: cardiovascular magnetic resonance reveals distinct differences in left ventricular mass, geometry, and function. Circulation 127(2), 197–206 (2013) OpenAlex ↗ · Scholar ↗
  15. Li, C., Xu, C., Gui, C., Fox, M.: Distance Regularized Level Set Evolution and Its Application to Image Segmentation. IEEE Transactions on Image Processing 19(12), 3243–3254 (2010) OpenAlex ↗ · Scholar ↗
  16. Long, J., Shelhamer, E., Darrell, T.: Fully Convolutional Networks for Semantic Segmentation. In: CVPR (2015) our card
  17. Ngo, T.A., Carneiro, G.: Fully Automated Non-rigid Segmentation with Distance Regularized Level Set Evolution Initialized and Constrained by Deep-Structured Inference. In: CVPR. pp. 3118–3125 (2014) OpenAlex ↗ · Scholar ↗
  18. Ngo, T.A., Carneiro, G.: Left ventricle segmentation from cardiac MRI combining level set methods with deep belief networks. In: ICIP. pp. 695–699 (2013) OpenAlex ↗ · Scholar ↗
  19. Ngo, T.A., Lu, Z., Carneiro, G.: Combining deep learning and level set for the automated segmentation of the left ventricle of the heart from cardiac cine magnetic resonance. Medical Image Analysis 35, 159–171 (2017) OpenAlex ↗ · Scholar ↗
  20. Petitjean, C., Dacher, J.N.: A review of segmentation methods in short axis cardiac MR images. Medical Image Analysis 15(2), 169–184 (2011) OpenAlex ↗ · Scholar ↗
  21. Radau, P., Lu, Y., Connelly, K., Paul, G., Dick, A.J., Wright, G.A.: Evaluation Framework for Algorithms Segmenting Short Axis Cardiac MRI. The MIDAS Journal – Cardiac MR Left Ventricle Segmentation Challenge (2009) OpenAlex ↗ · Scholar ↗
  22. Ronneberger, O., Fischer, P., Brox, T.: U-Net: Convolutional Networks for Biomedical Image Segmentation. In: MICCAI (2015) our card
  23. Sutskever, I., Hinton, G.E., Taylor, G.W.: The Recurrent Temporal Restricted Boltzmann Machine. In: NIPS, pp. 1601–1608 (2009) OpenAlex ↗ · Scholar ↗
  24. Tieleman, T., Hinton, G.: Lecture 6.5-rmsprop: Divide the gradient by a running average of its recent magnitude. COURSERA: Neural Networks for Machine Learning 4 (2012) OpenAlex ↗ · Scholar ↗
  25. Valipour, S., Siam, M., Jagersand, M., Ray, N.: Recurrent Fully Convolutional Networks for Video Segmentation. arXiv:1606.00487 [cs] (2016) OpenAlex ↗ · Scholar ↗