Elamur Research

Analysis of imperfections in practical continuous-variable quantum key distribution

Paper · 2012 · Paul Jouguet, Sébastien Kunz-Jacques, Eleni Diamanti et al.

Summary

A security proof describes a mathematical protocol. A working cryptographic device implements that protocol with finite precision, limited randomness, noisy components, and measurements that must be calibrated. The gap matters because an attacker interacts with the physical apparatus. This paper examines that gap for continuous-variable quantum key distribution, in which Alice and Bob use measurements of light to establish a shared secret key. Its central question is practical: which departures from the ideal protocol are harmless approximations, which weaken the security guarantee, and which can be accounted for more accurately to improve performance?

The authors study Gaussian prepare-and-measure protocols, concentrating on GG02. Alice selects random values for the optical quadratures, prepares corresponding coherent states, and sends them to Bob. Bob measures a randomly selected quadrature using homodyne detection. Their records are correlated but noisy; reconciliation makes their strings agree, and privacy amplification reduces the information potentially available to an eavesdropper, Eve. The paper examines imperfections in this process at different stages: the finite grid used to approximate Alice’s Gaussian choices, uncertainty in Bob’s detector calibration, and phase fluctuations during preparation.

The first result is encouraging but qualified. An intentionally designed discrete distribution can approximate the ideal Gaussian mixture extremely closely. For a Cartesian construction with modulation variance (V_A=20), the authors obtain a trace-distance bound of 3.31 × 10⁻¹¹ using an 8-bit grid for each coordinate. A related treatment of the distribution’s cutoff gives 2.98 × 10⁻¹¹. These are numerical bounds for precisely specified distributions. When the grid points themselves suffer small systematic disturbances, the preparation error grows much more quickly. The authors consequently distinguish the adequacy of finite discretization from the harder task of implementing that discretization accurately.

The calibration analysis finds another important distinction. Under the conditions studied, even relatively pessimistic uncertainties in detection efficiency and electronic noise have little effect on the calculated secret key rate. Uncertainty in shot noise is more consequential, particularly over long distances, because shot noise provides the reference against which small amounts of excess noise are estimated. Finally, the paper argues that independently characterized preparation phase noise can be treated as local noise outside Eve’s control. This does not restore Alice and Bob’s lost correlation. It prevents that loss from being attributed unnecessarily to Eve. In the reported asymptotic comparison, the resulting calculation extends the achievable distance by about 40 km.

Interesting ideas

Measure approximation where it affects the guarantee. A discrete Gaussian is visibly different from a continuous Gaussian, but visual resemblance is not the security criterion. The authors compare the quantum states produced by the respective preparation procedures. This moves the analysis from the random-number generator’s output to the object that an adversary can actually observe. The reusable principle is to judge an approximation at the interface relevant to the final claim. In numerical software, measurement systems, or randomized algorithms, a convenient internal discrepancy may say much less than an error measure tied directly to the system’s observable behavior.

Separate intended approximation from implementation error. The paper treats an exactly realized finite grid and a disturbed grid as different questions. That separation exposes a practical bottleneck: choosing a sufficiently fine grid can be straightforward even when placing its points accurately is difficult. Researchers can borrow this distinction whenever a design has a clean approximation theorem but depends on imperfect calibration or hardware. First establish what the planned approximation costs. Then test how sensitive that result is to departures from the plan. Combining the two too early can hide whether the problem lies in the mathematical construction or its physical realization.

Account for the reference measurement. Shot noise serves as a unit in the protocol, but its numerical value must still be measured. The authors therefore include the uncertainty of the reference alongside uncertainty in the signal. This is a useful lesson for evaluation and benchmarks: a normalized result inherits the limitations of the quantity used to normalize it. A baseline, calibration sample, or reference instrument should not disappear from the uncertainty analysis merely because later equations treat its value as a unit.

Assign uncertainty according to control and access. Preparation phase noise damages the correlation between Alice and Bob, yet the paper argues that it need not increase Eve’s knowledge of Bob’s data. The distinction depends on a physical account of where the noise acts and who can influence it. The transferable idea is to preserve causal provenance when interpreting errors. An observed discrepancy can arise from several mechanisms with different implications. Combining them into a single pessimistic category may conceal useful information; separating them is justified only when independent evidence supports the separation.

Use equivalent descriptions to simplify a difficult effect. The preparation protocol is easier to implement than to analyze directly. By examining an equivalent entanglement-based description, the authors place phase noise on Alice’s local measurement and make its effect on Eve’s information easier to understand. This suggests a general research strategy: seek an alternative representation that preserves the relevant observations while making control, dependence, or invariance explicit. Such a representation is especially valuable when a direct description mixes together effects that need different treatment.

Test the fragility of a strong bound. The very small discretization bounds would be easy to present as the practical conclusion. Instead, the paper perturbs the grid and checks how the guarantee changes. That sensitivity analysis substantially changes the interpretation of the nominal result. The broader lesson is that a strong bound becomes more useful when accompanied by a clear account of the conditions that sustain it. A result that survives only under exact placement, exact calibration, or exact distributional assumptions should make those dependencies visible.

Deep dive: Analysis of imperfections in practical continuous-variable quantum key distribution

How practical imperfections in Gaussian continuous-variable quantum key distribution affect security, calibration, and achievable secret key rates. · about 33 minutes to read

How Mova uses it

For Mova, a small transparent language system written in Rust, the relevance is methodological. The paper studies optical cryptography, so it provides no direct language-processing algorithm, linguistic representation, or text-processing result. There is no established implementation connection to report. Its useful contribution is a way of organizing claims about an ideal procedure, a finite implementation, and the evidence needed to connect them.

One possible application concerns finite representations. If a Mova component approximates a mathematical quantity with a bounded or discrete representation, its documentation could distinguish the deliberate approximation from errors introduced elsewhere in the implementation. The paper’s grid analysis offers a concrete pattern: specify the intended finite construction, identify the quantity that matters downstream, and evaluate the effect of disturbing the construction. For Mova, the relevant downstream quantity would have to come from its own task. The quantum trace-distance guarantee would not transfer.

A second possible application concerns measured references. A transparent system benefits from recording where its scores and thresholds come from. If a decision depends on a calibrated baseline, a reference distribution, or an estimated noise level, Mova could preserve that dependency rather than presenting the final value as self-explanatory. The paper shows why this matters: uncertainty in a reference can dominate a calculation even when other component uncertainties appear relatively harmless. Applying that lesson would require measurements specific to Mova, instead of borrowing the optical experiment’s numerical settings.

The phase-noise analysis also suggests a useful discipline for interpretability. An explanation should distinguish an observed failure from an inference about its cause. In the paper, reduced correlation does not automatically imply increased adversarial knowledge. For a language system, an analogous discipline would be to keep evidence about an output separate from assumptions about which component produced it. That is a possible design principle, not a demonstrated result about Mova.

Rust can make such distinctions explicit in a system’s data structures and interfaces, but the paper does not prescribe a software architecture. A practical adaptation would therefore begin with a modest goal: make assumptions, measurements, and derived conclusions inspectable. It would not attach a cryptographic interpretation to ordinary language-processing errors. The value of the connection lies in the paper’s insistence that an assurance claim should describe the implemented system and the evidence supporting it.

The problem and its context

Quantum key distribution aims to let distant parties establish a secret key while an adversary controls the environment between them. The security argument comes from quantum mechanics, but applying that argument requires a correspondence between the protocol in the proof and the apparatus in operation. The authors begin from a tension: the technology has reached practical use, while security proofs necessarily simplify the equipment.

An implementation can depart from those simplifications in ways that are irrelevant to ordinary operation yet important to an attacker. A device may still generate correlated data and produce matching keys while violating an assumption used to limit Eve’s information. The paper places its analysis against earlier demonstrations of attacks on commercial systems. Its concern is therefore not merely that ideal equations are aesthetically incomplete. An omitted physical behavior can create a channel through which an adversary gains information.

The authors describe different responses to this problem. Device-independent security reduces reliance on trusting the internal operation of Alice’s and Bob’s equipment. In the account given by the paper, this approach depends on violating a Bell inequality under demanding experimental conditions and did not yet provide a practical solution. The authors instead pursue a more immediate route: retain a detailed description of the devices, but refine it to include imperfections that the ideal protocol leaves out.

That choice makes the trust assumptions more explicit. A detector can be inefficient without being under Eve’s control. A preparation device can introduce local noise without revealing its fluctuations to the adversary. Conversely, calling an imperfection local does not make it safe by declaration. The apparatus must support that claim, and the relevant calibration must be protected from interference.

Why continuous variables make calibration central

The protocols considered here use homodyne detection rather than single-photon counters. Homodyne measurement gives a quadrature value: a continuous optical quantity that becomes a classical number in Bob’s record. Alice encodes information through random displacements in the corresponding quadratures. The paper emphasizes the practical appeal of this detection approach and its compatibility with wavelength division multiplexing, which matters for integration with telecommunications infrastructure.

The authors place continuous-variable protocols alongside photon-counting protocols in their theoretical security status. They cite security results against coherent attacks and explain that the asymptotic secret key expression is associated with collective attacks. This background matters because the paper is not trying to replace an insecure ideal protocol with a secure one. It asks how established theoretical guarantees should be interpreted when their preparation and detection assumptions meet real equipment.

The selected protocol, GG02, uses a Gaussian distribution for Alice’s modulation. Gaussian structure is mathematically convenient and central to the security analysis. Yet a true Gaussian distribution is continuous and has no finite boundary. Hardware provides finitely many settings, operates over finite ranges, and receives randomness at a finite rate. The intended distribution therefore cannot be reproduced exactly.

The paper makes these constraints concrete. It mentions converters with a bit depth of 10 and a physical random-number source limited to 16 Mbit/s. There is also a computational cost in turning uniform random bits into Gaussian values. These constraints motivate a sharper question than whether a Gaussian is physically exact: how accurately must the implemented ensemble reproduce the ideal quantum state for the security argument to remain useful?

What earlier calibration work had left open

Finite-size effects had already been studied for channel transmittance and excess noise. Those quantities are inferred from a finite collection of correlated measurements, so their estimates carry uncertainty. The earlier analysis discussed by the authors nonetheless treated detector efficiency, electronic noise, and shot noise as perfectly calibrated.

That assumption is particularly consequential for shot noise. In the usual presentation, several physical quantities are expressed in shot-noise units. This can make the reference appear fixed by definition. In an apparatus, however, the shot-noise level is an experimentally determined variance. If its estimate moves, the inferred values of other quantities move with it.

The paper therefore expands the parameter-estimation problem. It includes both statistical uncertainty from finite samples and imperfect knowledge of detector characteristics. These are related but distinct limitations. More calibration samples can reduce sampling uncertainty; they do not automatically eliminate the finite precision of measurement equipment.

Why preparation phase noise deserves separate treatment

The authors also discuss earlier work on preparation noise, particularly cases where Alice emits thermal states instead of coherent states. In the optical setting considered, they describe a practical way to mitigate that problem: increase modulation and then attenuate the output strongly. The resulting state can approach a coherent state.

Phase noise behaves differently. Increasing modulation and attenuating afterwards does not remove the relevant phase fluctuations in the same way. The paper cites a typical phase-noise variance of 10⁻⁴ N₀ per photon in a pulse and treats this imperfection as a persistent feature of preparation.

Its special importance comes from a symmetry. For Gaussian modulation, random phase fluctuations can leave the overall state sent into the channel unchanged while making Alice’s recorded values less closely aligned with the actual signal. The ensemble accessible to Eve can remain the same even as Alice and Bob’s classical correlation declines. This opens the possibility of a more accurate security calculation, provided the phase noise is measured independently and genuinely lies outside Eve’s control.

The method, step by step

The paper does not propose a new key-distribution protocol. It examines how to analyze an existing Gaussian protocol when preparation and measurement are imperfect. The method combines numerical approximation bounds, statistical parameter estimation, and a physical argument about local phase noise.

Connecting practical devices to the security calculation

The steps in order.

Connecting practical devices to the security calculationStep 1: Specify the ideal Gaussian preparation1. Specify the ideal Gaussian preparationStep 2: Construct finite modulation distributions2. Construct finite modulation distributionsStep 3: Bound preparation-state distinguishability3. Bound preparation-state distinguishabilityStep 4: Calibrate detector characteristics and shot noise4. Calibrate detector characteristics and shot noiseStep 5: Estimate channel parameters with uncertainty5. Estimate channel parameters with uncertaintyStep 6: Characterize trusted preparation phase noise6. Characterize trusted preparation phase noiseStep 7: Calculate the supported secret key rate7. Calculate the supported secret key rate

Start with the state preparation

In the ideal prepare-and-measure description, Alice independently draws quadrature values from a centered normal distribution:

q, p ∼ 𝒩(0, V_A)

The symbols q and p are the chosen quadrature coordinates. The notation 𝒩 denotes a normal distribution, its mean is 0, and V_A is the modulation variance.

She prepares the coherent state associated with the complex amplitude q + ip. Here i is the imaginary unit. A coherent state is the optical state used to represent that displacement, with shot noise still present around its center. Bob’s homodyne measurement samples a quadrature instead of revealing the displacement without uncertainty.

In practice, Alice prepares a state centered at a nearby attainable point. The set of attainable points is finite. The security analysis therefore compares the ideal ensemble with the actual ensemble, rather than demanding that every randomly chosen continuous value be implemented exactly.

The ideal state, when Alice’s private modulation choice is averaged out, is thermal:

ρ = Σₙ₌₀^∞ [x̄ⁿ / (x̄ + 1)ⁿ⁺¹] |n⟩⟨n|

The symbol ρ denotes the ideal density operator. The index n labels photon-number states |n⟩, and x̄ is the mean photon number. Each coefficient gives the probability associated with the corresponding photon-number component.

The finite preparation is written as:

σ = Σₖ ωₖ |αₖ⟩⟨αₖ|

The symbol σ denotes the implemented density operator. The index k ranges over available coherent states, αₖ identifies a state’s complex amplitude, and ωₖ is the probability of preparing it. The probabilities are normalized.

The relevant comparison uses the trace norm of the difference:

ε_prep = ‖ρ − σ‖₁

The quantity ε_prep bounds preparation distinguishability in the paper’s convention. The notation ‖·‖₁ denotes the trace norm. The authors use this distance to connect an approximation of the emitted state with the security parameter.

Their accounting rule is additive:

ε_actual = ε + ε_prep

The symbol ε is the security parameter for ideal preparation, while ε_actual is the parameter supported after including the preparation discrepancy. This is why a seemingly small physical mismatch must be evaluated against a demanding security target. The paper discusses ε_prep on the order of 10⁻¹⁰ for a realistic implementation.

Reduce an infinite-dimensional comparison to computable terms

Optical states occupy an infinite-dimensional space. A numerical calculation cannot inspect every photon-number component directly. The authors introduce a projector onto a finite subspace:

Π = Σₙ₌₀^(Q−1) |n⟩⟨n|

The symbol Π is the projection operator, and Q is the cutoff dimension. It retains photon-number components below Q. The omitted part must still be bounded; otherwise, a small difference inside the retained subspace could hide a large discrepancy outside it.

The gentle measurement lemma supplies the required control:

‖ρ − ΠρΠ‖₁ ≤ 2√[1 − tr(ΠρΠ)]

The function tr takes the trace. The expression tr(ΠρΠ) is the probability mass retained by the projection. The bound connects lost probability mass to the disturbance associated with restricting the state.

The resulting preparation bound separates different sources of error:

‖ρ − σ‖₁ ≤ [x̄/(x̄ + 1)]^Q + Δ_diag + 2Δ_nondiag + 2√R_σ

The first term is the ideal thermal tail beyond the cutoff. The quantity Δ_diag measures disagreement between retained diagonal entries. The quantity Δ_nondiag collects off-diagonal entries of the implemented state, which should vanish for the ideal thermal state. The quantity R_σ is the implemented state’s probability mass outside the retained subspace.

The diagonal contribution is:

Δ_diag = Σ₀≤n<Q |x̄ⁿ/(x̄ + 1)ⁿ⁺¹ − ⟨n|σ|n⟩|

The matrix element ⟨n|σ|n⟩ is the implemented probability in photon-number state n. This term checks whether the finite preparation reproduces the thermal population of each retained component.

The off-diagonal contribution is:

Δ_nondiag = Σ₀≤n<m<Q |⟨n|σ|m⟩|

The indices n and m refer to different retained photon-number states. Their matrix elements measure coherence that would be absent from the ideal thermal mixture.

The remaining probability is:

R_σ = 1 − Σ₀≤n<Q ⟨n|σ|n⟩

The expression subtracts the retained probability from the state’s total probability. It is particularly demanding because it enters the distance bound through a square root.

The paper relates modulation variance to the thermal mean through:

x̄ = 2V_A

Here V_A is expressed in shot-noise units. Larger modulation therefore requires a larger photon-number cutoff to make the unexamined tail sufficiently small. The cutoff is a numerical analysis choice, not an additional physical modulation setting.

Construct the Cartesian approximation

The Cartesian construction places a finite grid along each quadrature axis:

q_k = p_k = (A/N)k

The integer k ranges from −N to N. The parameter A sets the largest coordinate magnitude, while N controls how finely that interval is divided. In this subsection, N is a grid parameter; later, the paper reuses N for the number of transmitted signals.

The grid spacing is:

δ = A/N

The symbol δ is the distance between neighboring coordinate values. It is compared with the shot-noise scale because a coherent state already has finite quantum uncertainty around its center.

The coordinate probabilities follow Gaussian-shaped weights:

ω_k = exp[−q_k²/(2V)] / Σⱼ exp[−q_j²/(2V)]

The symbol V is the variance parameter appearing in the paper’s discretized weighting expression. The denominator normalizes the weights over the retained grid. The index j runs over the same available coordinates.

The joint preparation combines coordinate choices:

σ = Σₖ₌₋N^N Σₗ₌₋N^N ω_kω_l |α_kl⟩⟨α_kl|

The indices k and l select the respective quadrature coordinates. Their probabilities multiply because the coordinates are drawn independently. The amplitude α_kl equals q_k + ip_l.

The numerical matrix entries follow from the coherent-state expansion:

⟨n|σ|m⟩ = Σₖ,ₗ ω_kω_l exp(−|α_kl|²) α_klⁿ(α_kl*)ᵐ / √(n!m!)

The asterisk indicates complex conjugation, and the exclamation marks denote factorials. This expression supplies the entries needed for the diagonal, off-diagonal, and tail calculations. It is the bridge between a practical list of displacement settings and the quantum-state distance used in the security argument.

The authors then choose a finite range and spacing, evaluate the bound, and repeat the calculation for a different allocation of the probability lost at the cutoff. In the main construction, truncation is handled through normalization across retained points. In the alternative, the omitted probability is assigned to boundary values. This tests whether a modest change in the cutoff procedure substantially affects the result.

Compare a polar construction

The physical preparation devices separately modulate phase and intensity, making polar coordinates a natural alternative. A uniform polar grid uses:

r_k = (k + 1/2)R/K

The symbol r_k is a retained radius. The parameter R is the radial boundary, K is the number of radial settings, and k ranges over those settings.

The corresponding angular values are:

θ_l = (l + 1/2)2π/L

The symbol θ_l is a retained phase angle, π is the circle constant, L is the number of angular settings, and l indexes them.

The radial weights include the radial factor:

ω_k = r_k exp[−r_k²/(2V)] / Σⱼ r_j exp[−r_j²/(2V)]

These weights differ from the Cartesian coordinate weights because the Gaussian probability assigned to a ring depends on its radius. The phase choices are equally weighted.

A useful simplification appears in the photon-number entries:

⟨n|σ|m⟩ = U_nm,L Σₖ ω_k exp(−r_k²) r_k^(n+m) / √(n!m!)

The factor U_nm,L is 1 when L divides n − m and 0 otherwise. It expresses cancellation across the equally spaced angles. With a suitable relationship between angular resolution and the photon-number cutoff, this cancellation removes the retained off-diagonal contribution.

That simplification does not make uniform polar sampling efficient overall. The radial discretization becomes demanding. The authors therefore also consider radial locations chosen through Gaussian quadrature, especially the Gauss–Hermite variant. This changes where samples are placed rather than merely adding more uniformly spaced samples.

Disturb the planned grid

The nominal calculations assume that the prescribed displacement values are realized. To test sensitivity, the authors add a Gaussian-distributed disturbance to each Cartesian grid point. Its standard deviation is denoted σ_error.

This disturbance represents a different issue from the random modulation itself. It stands for inaccuracies in the grid’s placement, such as calibration errors or effects of the modulator’s voltage-to-amplitude response. The paper gives a cosine-shaped response as an example:

A = cos(cV + φ)

In this expression, A is the modulated amplitude, V is applied voltage, and c and φ characterize the response. These symbols have local meanings distinct from the grid boundary and modulation variance used elsewhere. Discrete voltages passed through such a response need not produce the ideal displacement grid.

The disturbance experiment asks whether the exceptionally small nominal preparation error survives this additional imperfection. The answer is less favorable than the ideal discretization calculation, which is why the authors discuss implementation robustness separately.

Calibrate detection before estimating the channel

The detector analysis distinguishes efficiency from electronic noise. The efficiency η describes the fraction retained in the equivalent detection process. The electronic variance v_el accounts for noise in the detection electronics.

The paper combines these effects into an input-referred detector-noise quantity:

χ_hom = (1 + v_el)/η − 1

The symbol χ_hom is the added noise referred to the measurement device’s input. Under the detection description used here, different combinations of η and v_el with the same χ_hom have the same effect on the final key-rate calculation.

For the fiber-based apparatus, efficiency is assembled from measurable contributions:

η = η_mod² η_phot η_opt

The quantities η_mod, η_phot, and η_opt denote interferometer mode matching, photodiode efficiency, and optical transmittance. Mode matching enters quadratically.

The propagated uncertainty is:

Δη = η[2Δη_mod/η_mod + Δη_phot/η_phot + Δη_opt/η_opt]

Each Δ denotes uncertainty in the associated measured quantity. This expression makes clear why knowing the detector’s nominal efficiency is insufficient: the calculation also needs an account of how accurately its components were measured.

Electronic noise can be estimated directly with no light entering the detector. The paper also discusses fitting output variance against input optical power and using the intercept, but reports that this alternative gives less accurate electronic-noise estimates. Calibration is assumed to occur under conditions where Eve cannot influence the apparatus.

Estimate the channel and its reference noise

Alice and Bob obtain pairs of centered classical values x and y. Their second moments satisfy:

⟨x²⟩ = V_A

The brackets denote expectation. This equation identifies Alice’s modulation variance from her values.

Bob’s variance is:

⟨y²⟩ = ηTV_A + N₀ + ηTξ + v_el

The symbol T is channel transmittance, N₀ is shot-noise variance, and ξ is excess noise. The terms represent transmitted modulation, shot noise, transmitted excess noise, and detector electronic noise. At this stage the quantities are expressed in their respective physical units, before normalization to shot noise.

The cross-correlation is:

⟨xy⟩ = √(ηT)V_A

This relates Alice and Bob’s covariance to the transmission factor and Alice’s variance.

Even with detector characteristics calibrated, the signal statistics alone do not determine every unknown. Bob therefore measures vacuum, obtaining another variance:

⟨y₀²⟩ = N₀ + v_el

The variable y₀ denotes detector output with zero channel transmittance. This additional observation separates the reference noise from contributions present when signals are exchanged.

For statistical estimation, the paper assumes a normal linear relationship:

y = tx + z

The coefficient t equals √(ηT). The residual z is centered normal noise with variance σ². This assumption supports tractable confidence intervals, but the authors explicitly distinguish its practical justification from what the cited security arguments establish.

The residual variance is:

σ² = N₀ + ηTξ + v_el

The separate vacuum residual has variance σ₀² = N₀ + v_el. These quantities allow excess noise to be inferred by comparing signal residuals with vacuum measurements.

The transmission coefficient is estimated by:

t̂ = Σᵢ₌₁^N x_i y_i / Σᵢ₌₁^N x_i²

The hat indicates an estimate, and N now denotes the signal sample count. The index i labels paired observations.

The signal residual variance estimator is:

σ̂² = (1/N)Σᵢ₌₁^N (y_i − t̂x_i)²

This averages the squared residual after fitting the coefficient. It estimates the part of Bob’s variance not explained by the fitted transmitted signal.

The vacuum variance estimator is:

σ̂₀² = (1/N′)Σᵢ₌₁^N′ y₀,i²

The symbol N′ is the vacuum sample count. Its finite value matters because the shot-noise reference is inferred from these observations.

Alice’s variance estimator is:

V̂_A = (1/N)Σᵢ₌₁^N x_i²

This estimates her modulation variance from centered data. The paper uses the distributions of these estimators to construct large-sample confidence intervals.

For instance, the uncertainty width associated with t is written as:

ΔT = z_(ε_PE/2) √[σ̂²/(NV_A)]

The symbol ΔT is the paper’s notation for the interval width around t, in spite of T also denoting channel transmittance elsewhere. The factor z_(ε_PE/2) is a normal-tail confidence multiplier, and ε_PE is the allowed parameter-estimation failure probability.

The variance widths scale similarly:

Δσ² = z_(ε_PE/2) σ̂²√2/√N

This is the uncertainty width for the signal residual variance. The vacuum and modulation-variance widths have the corresponding forms with their respective variance estimates and sample counts. The important dependency is explicit: improving statistical precision requires more observations.

Turn parameter uncertainty into a key-rate claim

The protocol first needs a rough signal-to-noise estimate to choose a reconciliation code. The paper describes this preliminary sampling requirement as m = O(√N). After successful reverse reconciliation, Alice has access to the reconciled information needed for parameter estimation over the full string.

This distinction matters operationally. The preliminary estimate supports a coding choice; the later estimate supports a bound on Eve’s information. Treating the preliminary sample as the only usable information would miss the tighter estimate available after reconciliation.

The finite-size secret key rate is:

K_finite = (n/N)[βI(x:y) − S_ε_PE(y:E) − Δ(n)]

The quantity K_finite is the secret key rate including the stated finite-size and calibration effects. The ratio n/N accounts for signals retained for key establishment. The mutual information I(x:y) measures Alice and Bob’s shared classical information, and β is reconciliation efficiency. The term S_ε_PE(y:E) is the largest Eve–Bob information compatible with the statistical constraints, apart from the permitted parameter-estimation failure probability. The correction Δ(n) accounts for privacy amplification security.

The calculation must use uncertainty intervals rather than treating estimates as exact truths. It must also normalize quantities consistently using the measured shot noise. The paper’s contribution is to bring these calibration dependencies into the same calculation as the signal statistics.

Describe phase noise through an equivalent local operation

For preparation phase noise, the authors use an equivalent entanglement-based description. Alice can be regarded as preparing a shared state, measuring her local part, and sending the other part towards Bob. Random phase fluctuations can then be assigned to an operation on Alice’s side.

A phase rotation is written as:

U(θ) = exp(iθa†a)

The symbol θ is a random phase angle. The operators a† and a are creation and annihilation operators, and their product is the photon-number operator. The distribution p(θ) specifies how phase angles are sampled.

The noisy preparation associated with intended amplitude α is:

ρ_α = ∫ U(θ)|α⟩⟨α|U(θ)† p(θ)dθ

The dagger denotes the adjoint. The integral averages the rotated coherent states over the phase distribution.

For a symmetric phase distribution, the relevant correlation parameter is:

κ = (E[cos θ])²

The notation E denotes expectation. Symmetry removes the average sine contribution. The parameter κ summarizes how the phase fluctuations attenuate the correlation between Alice’s and Bob’s descriptions.

The covariance matrix after the channel is:

Γ_AB = [[V_A I₂, √(κT)Wσ_z], [√(κT)Wσ_z, (T(V_A − 1) + 1 + Tξ)I₂]]

The symbols Γ_AB, I₂, and σ_z denote the joint covariance matrix, the identity matrix of the quadrature block, and diag(1, −1), respectively. The quantity W equals √(V_A² − 1). In this entanglement-based passage, V_A denotes the variance used for the shared-state description, so its role must be distinguished from the displacement variance used earlier.

The structure is the important point: phase noise attenuates the cross-correlation while leaving the local variance blocks unchanged. The ensemble sent into the channel is invariant under the relevant phase averaging.

The asymptotic rate is:

K_asympt = βI(x:y) − χ(y:E)

The quantity χ(y:E) bounds Eve’s information about Bob’s outcomes. Because the raw key is based on Bob’s values in reverse reconciliation, local noise on Alice’s side reduces I(x:y) without increasing this Eve–Bob information term.

Measure the phase noise independently

The proposed calibration compares intended modulation with a measured quadrature. If Alice prepares amplitude A at angle φ relative to the measured quadrature, the output contains a signal A cos φ and a residual B.

The residual is decomposed as:

B = B_∥ cos φ + B_⊥ sin φ

The components B_∥ and B_⊥ are parallel and perpendicular to the intended signal. The paper assumes that these components are independent of φ.

Under the stated noise assumptions, the perpendicular variance is:

V[B_⊥] = N₀ + E[sin²θ]E[A²]

The notation V denotes variance. The perpendicular component contains shot noise plus the contribution from phase fluctuations. The factorization uses the assumptions about the phase and signal.

The measurable phase quantity is:

E₁ = [V[B_⊥] − N₀]/E[A²]

The symbol E₁ denotes the inferred value of E[sin²θ]. Subtracting shot noise is therefore part of this calibration too.

For small phase fluctuations, the paper uses:

E[cos θ] ≈ 1 − E₁/2

This approximation connects the measured perpendicular noise with κ. It relies on the small-angle regime and on the assumptions used to isolate phase noise from other possible contributions.

The calibration must be protected. If Eve could cause Alice to overestimate the local phase noise, Alice and Bob might subtract too much from what they attribute to the channel and claim an unjustifiably high key rate.

Experiments and results

The evidence combines numerical state-distance calculations, calculated key-rate curves, and an experimental phase-noise measurement. There is no learning procedure or text dataset. Each result concerns a specified optical setting or a mathematically defined preparation distribution. Keeping these evidence types separate is essential: a bound for an exact distribution, an estimated apparatus characteristic, and a calculated operating distance support different claims.

A finite Cartesian grid can be extremely close to the ideal state

For the main Cartesian example, the modulation variance is V_A=20. The authors choose the boundary A=7√V_A, truncating the distribution at 7 standard deviations along each coordinate. They set N=⌈4A⌉ to obtain spacing on the scale of 1/4 of a shot-noise unit.

This construction requires 253 possible coordinate values and fits an 8-bit discretization grid. The entropy is 6.2 bits per coordinate, or 12.4 bits for the pair. The distinction between addressable grid size and sampling entropy matters: source coding can reduce average randomness consumption towards the distribution’s entropy rather than requiring a fixed full-width draw for every coordinate.

For the numerical state comparison, the photon-number cutoff is Q=2000. The reported diagonal discrepancy is bounded by 1.02 × 10⁻¹¹, the off-diagonal contribution by 1.04 × 10⁻¹¹, and the implemented tail probability by 1.09 × 10⁻²⁴. Together with the ideal tail, these give the trace-distance bound of 3.31 × 10⁻¹¹.

These quantities establish that finite range and finite resolution need not be the dominant obstacle to a stringent preparation guarantee. The result is tied to the specified grid, probabilities, variance, and numerical cutoff. It does not establish that every apparatus with an 8-bit control input produces an equally accurate optical ensemble.

The alternative cutoff allocation assigns lost probability to boundary values rather than spreading its effect through normalization across all retained points. With the same main settings, its reported bound is 2.98 × 10⁻¹¹. Both constructions therefore support the same qualitative conclusion about deliberate discretization, in spite of their different treatment of the tails.

Uniform polar sampling is more demanding

The polar comparison keeps V_A=20 and uses Q=L=2000 with radial boundary R=7√V_A. The angular choice eliminates the retained off-diagonal contribution, but the radial approximation remains costly.

The authors report that a 17-bit amplitude discretization is needed to make the vacuum-component discrepancy no greater than 10⁻¹⁰. Sampling this uniform polar construction consumes 11 bits for angle and an average of 15.5 bits for modulus. The vacuum-component test is a specific part of the approximation analysis; it should not be confused with the full trace-distance bound established for the Cartesian example.

Using Gauss–Hermite radial placement improves the situation. The paper reports that a 9-bit amplitude discretization entropy is sufficient for ε_prep≤10⁻¹⁰. This is a result about nonuniformly chosen radial points, not a claim that polar coordinates are inherently unsuitable.

The authors also suggest that angular resolution could vary with radius because fewer distinct angles are needed near the origin. That is a proposed improvement instead of a fully evaluated setting in the reported analysis.

Grid disturbance weakens the nominal guarantee

When the Cartesian grid is disturbed by Gaussian placement errors, the numerical relationship is approximately ‖ρ−σ‖≈0.1 × σ_error under the tested settings. This shows that the ideal distribution’s very small error does not imply equal robustness to inaccurate control.

The authors consequently regard preparation errors around 10⁻⁴ or 10⁻⁵ as more realistic than reliably reaching 10⁻¹⁰ in practice. These values describe their assessment of implementable preparation accuracy. They are not a replacement theorem establishing the same final security guarantee at those larger errors.

The distinction is central to reading the paper fairly. The nominal discretization calculation demonstrates sufficiency of a well-chosen finite ensemble. The disturbance analysis identifies the challenge of realizing that ensemble precisely.

Detector calibration and finite samples

The finite-size key-rate curves use V_A=2.5, excess noise ξ=0.01, detector efficiency η=0.6, and electronic noise v_el=0.01. The fiber loss coefficient is α=0.2 dB/km, reconciliation efficiency is β=95%, and the security parameter is ε=10⁻¹⁰.

The calculations include Δη=0.1η and Δv_el=0.1v_el. These are deliberately substantial relative uncertainties in detector characteristics. Under the reported setting, their influence on key rate is not significant compared with the importance of accurate shot-noise estimation.

The curves compare the asymptotic calculation with sample counts 10¹⁰, 10⁹, 10⁸, 10⁷, and 10⁶, taking N=N′. The figure orders them from better to worse performance as sample size declines. Exact rates or distance endpoints are not stated numerically in the accompanying discussion, so the supported conclusion concerns the trend and the explicit positive-rate observation.

In particular, the authors report a positive secret key rate with 10⁶ samples for the Gaussian protocol. They contrast this with the discrete-modulation protocols discussed in the earlier finite-size work, where at least 10⁸ samples were required. This comparison concerns the analyses and conditions being discussed. It does not provide a universal sample-complexity ranking across all possible implementations.

The distance dependence is calculated through the fiber attenuation relation:

T = 10^(−αd/10)

The symbol d is transmission distance, α is the fiber loss coefficient, and T is channel transmittance. As transmission decreases, the channel contribution containing excess noise becomes harder to separate accurately from the reference and detector contributions.

Phase-noise calibration changes the attributed excess noise

For the phase-noise comparison, the authors consider an initial excess-noise level of about 2.5% of shot noise. They use modulation variance V_A=2.5 and report an experimental measurement E₁=3 × 10⁻³ from an apparatus similar to the earlier experimental system they cite.

Accounting for the independently characterized preparation phase noise yields an excess-noise value ξ_real=1.75%. The comparison below concerns the noise attributed in the security calculation. It does not mean that calibration physically removes the phase fluctuations.

Excess noise attributed in the phase-noise comparison

Calibrating local preparation noise reduces the excess noise assigned to the channel.

Excess noise attributed in the phase-noise comparisonAll preparation noise attributed to Eve: 2.5All preparation noise attributed to Eve2.5Calibrated local phase noise (this paper): 1.75Calibrated local phase noise (thispaper)1.75
The numbers
System or setting% of shot noise
All preparation noise attributed to Eve2.5
Calibrated local phase noise (this paper)1.75

The associated key-rate calculation is asymptotic and concerns collective attacks. It uses α=0.2 dB/km and β=95%. Detector inefficiency and electronic noise are omitted in this comparison to isolate the phase-noise effect.

The reported increase in achievable distance is about 40 km. This is a calculated consequence of the measured phase-noise quantity and the selected assumptions. It is not presented as a direct transmission demonstration of the full distance increase.

The reason for the improvement is precise. Alice and Bob retain the mutual-information penalty caused by their imperfect correlation, but the security calculation no longer grants Eve information associated solely with trusted local preparation noise. Better characterization improves the accounting without improving the physical signal itself.

What the ablations show

The paper does not contain a conventional component-removal ablation study. It instead offers controlled comparisons of approximation schemes, calibration assumptions, and noise attribution, together with a sensitivity analysis of disturbed modulation points.

Coordinate choice changes the cost of approximation

The Cartesian and polar constructions target the same thermal state but distribute their finite settings differently. This comparison shows that a coordinate system convenient for the physical actuator need not be efficient for the approximation bound.

Uniform angular sampling has a useful cancellation property in the photon-number representation. Yet that advantage does not compensate automatically for the radial resolution demanded by a uniform polar grid. The difficulty is therefore more specific than a general failure of polar preparation: uniform radial placement is a costly choice for this target distribution.

The Gauss–Hermite comparison reinforces that interpretation. Changing the radial locations improves the required discretization substantially without abandoning polar coordinates. The result supports adaptive placement of approximation resources, while the suggested radius-dependent angular spacing remains an avenue for further improvement.

Tail handling is less decisive than grid accuracy

The cutoff comparison changes how probability outside the finite range is reassigned. Both tested schemes achieve a very small preparation bound. This suggests that the central success does not depend narrowly on a single tail-normalization convention.

The disturbance analysis is more consequential. It alters the realized locations instead of the intended probability bookkeeping. The resulting sensitivity shows that an apparently minor physical departure can matter more than the deliberate choice between closely related discretization schemes.

These comparisons distinguish two engineering questions that could otherwise be conflated. One asks how to design a finite distribution. The other asks how accurately the modulator realizes its design. The paper supports confidence about the former while preserving concern about the latter.

Not every calibration uncertainty has equal impact

The detector study includes sizeable uncertainty in efficiency and electronic noise but finds little effect on the calculated rate under its chosen parameters. This does not make those characteristics irrelevant. It indicates that the rate is comparatively insensitive to the tested calibration intervals in that operating regime.

Shot noise plays a different role because it is both a physical noise contribution and the normalization reference. Long-distance excess-noise estimation depends on resolving a small channel-dependent contribution against that reference. The analysis therefore directs attention toward the measurement whose uncertainty most strongly limits the final claim.

This is a useful outcome of the comparison even without a table of isolated rate changes. It identifies where additional calibration effort is likely to matter under the reported conditions, instead of treating every apparatus uncertainty as equally urgent.

Noise attribution changes assurance, not the observations

The phase-noise comparison holds the observed correlation loss conceptually separate from its security interpretation. Under the more pessimistic treatment, the entire discrepancy is available to Eve. Under the calibrated treatment, the independently established local contribution is excluded from her information calculation.

The improvement therefore does not demonstrate that phase noise is beneficial. Alice and Bob would still prefer stronger useful correlation. What benefits them is avoiding an unnecessarily pessimistic assignment of an existing imperfection.

The reverse-reconciliation condition is essential. Bob’s outcomes define the raw key, so a local degradation of Alice’s record can leave Eve’s information about that key unchanged. The authors explicitly caution that the same statement does not carry over to direct reconciliation, where Alice’s noisy data would define the raw key instead.

Limitations

Limits stated by the authors

The authors’ strongest practical qualification concerns preparation accuracy. Their finite-grid calculation assumes exact probabilities and exact coherent-state locations. The disturbance analysis shows that real control errors can produce much larger preparation discrepancies. The paper therefore does not support a general claim that ordinary discretized hardware automatically achieves a preparation parameter near 10⁻¹⁰.

The authors also identify a limitation in the available proof technique. The preparation distance is added to the final security parameter, which makes implementation inaccuracies expensive in the guarantee. They suggest that this may be overly pessimistic because earlier work establishes security for non-Gaussian modulation against attacks corresponding to a linear channel. That observation motivates further investigation; it does not prove that preparation errors around 10⁻⁴ or 10⁻⁵ are sufficient against every attack covered by the ideal Gaussian analysis.

The normal assumption used for finite-size estimation is another explicit qualification. The authors regard it as justified in practice, while noting that the cited security arguments establish the relevance of Gaussian structure after the covariance matrix is known. That does not on its own justify every distributional assumption used to construct finite-sample confidence intervals. They suggest exploiting protocol symmetries as a possible route to a more rigorous foundation.

Calibration must occur under trusted conditions. Detector characteristics measured in a secure laboratory are treated differently from channel behavior that Eve may control. Preparation phase-noise calibration requires a comparable assumption. If an adversary can influence the calibration, the separation between trusted local noise and untrusted channel noise can become invalid.

The paper explicitly emphasizes the danger of overestimating phase noise. Such an overestimate could cause too much observed noise to be removed from Eve’s information calculation. The resulting key-rate claim would then be too optimistic. Accurate local characterization is therefore a security requirement, rather than merely a way to obtain better performance.

Limits visible in the scope of the evidence

The numerical discretization results are examples at specified parameter choices. They demonstrate that a suitable bounded distribution can work extremely well, but they do not establish a hardware-independent prescription for every variance, actuator response, or randomness source. Larger modulation changes the photon-number tail and can require a larger numerical cutoff.

The grid-disturbance experiment is informative but limited. It adds disturbances with a particular distribution and summarizes the observed scaling under the tested conditions. Actual implementation errors may have different structure. The study should be read as evidence of sensitivity, rather than a complete characterization of every possible modulator imperfection.

The calibration curves likewise examine a selected operating point. Their finding that efficiency and electronic-noise uncertainty have little effect applies to that calculation. A different apparatus or operating regime could change which uncertainty dominates. The paper does not establish a universal ordering that makes some detector calibrations dispensable.

The phase-noise distance gain has an especially important boundary. It belongs to an asymptotic comparison for collective attacks, with detection inefficiency and electronic noise omitted for clarity. It should not be combined silently with the finite-size calibration curves as though all reported improvements had been demonstrated together in a complete apparatus calculation.

The phase calibration also assumes that shot noise and phase noise are the relevant contributors to the perpendicular component. If another effect contributes to that measured variance, interpreting all of it as trusted phase noise would require additional justification. The small-angle approximation further limits the direct use of the stated relation between E₁ and the average cosine.

Algebraic and notation issues that require care

Some printed equations need checking before they are used as an implementation specification. In the phase-noise parameter conversion, the paper defines effective transmittance through T′=Tκ and also equates the corresponding Bob-side variances. The subsequently displayed expression for converting ξ′ to ξ is not algebraically consistent with both of those preceding relations as written. A reader should verify the conversion rather than copy the final displayed expression into a key-rate calculation.

A separate issue appears in the phase-noise calibration derivation. The printed formulas for V[B cos φ] and V[B sin φ] give identical weighted combinations of the parallel and perpendicular variances. As printed, they do not provide independent equations from which both component variances can be recovered, despite the accompanying claim. The proposed separation therefore needs the intended projection relation to be checked.

These issues do not erase the physical distinction between local preparation noise and Eve-controlled noise. They do limit how directly the printed algebra can be translated into operational software. The reported experimental quantity and rate comparison remain claims of the paper; the incomplete consistency of the displayed derivation should remain visible alongside them.

The notation also changes across sections. N first controls grid resolution and later counts signals. V_A is used for displacement modulation and, in the entanglement-based passage, for a shared-state variance. The confidence-interval discussion introduces its own conventions for widths and sample counts. These changes are manageable for a reader following the argument, but they make a literal transfer of equations risky.

What the security conclusions do not establish

The analysis addresses selected preparation and detection imperfections. It does not certify an entire implementation against every side channel. The paper’s broader motivation is that omitted behavior can invalidate a proof, and examining these imperfections cannot establish that no others exist.

The trusted-noise argument is conditional on physical control and independence. It should not be generalized to arbitrary unexplained noise. An unidentified contribution remains unidentified even when assigning it locally would improve the rate. The paper’s benefit comes from characterization that supports a more precise account of Eve’s access.

Finally, improved calculated distance is an assurance result under stated assumptions. It is not a claim that calibration changes fiber attenuation, makes reconciliation perfect, or removes the phase fluctuations themselves. The practical value is that a better description can support key extraction where a more pessimistic description would reject it.

What came after

The paper’s forward-looking contribution is a research agenda centered on implementation-aware security. It points toward more efficient nonuniform modulation grids, preparation bounds that may be less pessimistic about small deviations, and stronger foundations for finite-size estimation assumptions. These are directions identified by the authors, rather than completed results established by their analysis.

Its treatment of phase noise also poses a durable question for subsequent work: which observed imperfections genuinely increase an adversary’s information, and which only weaken the legitimate parties’ correlation? Answering that question requires both a mathematical argument and a defensible account of the apparatus. The paper demonstrates the value of bringing those forms of evidence together.

No specific subsequent study is established here as extending these results. The supported conclusion is therefore about the contribution itself: practical security depends on describing finite preparation, measured references, and local noise precisely enough that the guarantee applies to the equipment actually used.

Cite

Cite as Paul Jouguet, Sébastien Kunz-Jacques, Eleni Diamanti and Anthony Leverrier. 2012. Analysis of imperfections in practical continuous-variable quantum key distribution. Physical Review A.

The paper itself, not this page. BibTeX from the library's record of the work. DOI 10.1103/physreva.86.032309 · arXiv 1206.6357

@article{jouguet2012analysis,
  title = {{Analysis of imperfections in practical continuous-variable quantum key distribution}},
  author = {Paul Jouguet, Sébastien Kunz-Jacques, Eleni Diamanti and Anthony Leverrier},
  journal = {Physical Review A},
  year = {2012},
  doi = {10.1103/physreva.86.032309},
  eprint = {1206.6357},
  archivePrefix = {arXiv},
  url = {https://doi.org/10.1103/physreva.86.032309}
}

↑ back to top

This page in Markdown https://md.research.elamur.ai/free/en/papers/jouguet-2012-analysis-imperfections-practical-continuous-variable/

References

39 references, from the paper's own bibliography.

  1. authorV. Scarani, authorH. Bechmann-Pasquinucci, authorN. Cerf, authorM. Dušek, authorN. Lütkenhaus, and authorM. Peev, journalRev. Mod. Phys. volume81, eid1301 (year2009). OpenAlex ↗ · Scholar ↗
  2. authorV. Scarani and authorC. Kurtsiefer, journalArxiv preprint arXiv:0906.4547 (year2009). OpenAlex ↗ · Scholar ↗
  3. authorF. Xu, authorB. Qi, and authorH. Lo, journalNew J. Phys. volume12, pages113026 (year2010). OpenAlex ↗ · Scholar ↗
  4. authorL. Lydersen, authorC. Wiechers, authorC. Wittmann, authorD. Elser, authorJ. Skaar, and authorV. Makarov, journalNature Photonics volume4, pages686 (year2010). OpenAlex ↗ · Scholar ↗
  5. authorA. Ekert, journalPhys. Rev. Lett. volume67, pages661 (year1991). OpenAlex ↗ · Scholar ↗
  6. authorB. Qi, authorW. Zhu, authorL. Qian, and authorH. Lo, journalNew J. Phys. volume12, pages103042 (year2010). OpenAlex ↗ · Scholar ↗
  7. authorR. Renner and authorJ. I. Cirac, journalPhys. Rev. Lett. volume102, pages110504 (year2009). OpenAlex ↗ · Scholar ↗
  8. authorF. Furrer, authorT. Franz, authorM. Berta, authorA. Leverrier, authorV. Scholz, authorM. Tomamichel, and authorR. Werner, journalArxiv preprint ArXiv:1112.2179 (year2011). OpenAlex ↗ · Scholar ↗
  9. authorA. Leverrier, authorR. García-Patrón, authorR. Renner, and authorN. J. Cerf, journalin preparation (year2012). OpenAlex ↗ · Scholar ↗
  10. authorI. Devetak and authorA. Winter, in booktitleProc. R. Soc. A (year2005), vol. volume461, p. pages207. OpenAlex ↗ · Scholar ↗
  11. authorM. Berta, authorF. Furrer, and authorV. Scholz, journalArxiv preprint arXiv:1107.5460 (year2011). OpenAlex ↗ · Scholar ↗
  12. authorR. García-Patrón and authorN. J. Cerf, journalPhys. Rev. Lett. volume97, pages190503 (year2006). OpenAlex ↗ · Scholar ↗
  13. authorM. Navascués, authorF. Grosshans, and authorA. Acín, journalPhys. Rev. Lett. volume97, pages190502 (year2006). OpenAlex ↗ · Scholar ↗
  14. authorC. Bennett and authorG. Brassard, in booktitleProceedings of IEEE International Conference on Computers, Systems, and Signal Processing (year1984), vol. volume175. OpenAlex ↗ · Scholar ↗
  15. authorF. Grosshans, authorG. Van Assche, authorJ. Wenger, authorR. Brouri, authorN. Cerf, and authorP. Grangier, journalNature volume421, pages238 (year2003). OpenAlex ↗ · Scholar ↗
  16. authorA. Lance, authorT. Symul, authorV. Sharma, authorC. Weedbrook, authorT. Ralph, and authorP. Lam, journalPhys. Rev. Lett. volume95, pages180503 (year2005). OpenAlex ↗ · Scholar ↗
  17. authorJ. Lodewyck, authorM. Bloch, authorR. García-Patrón, authorS. Fossier, authorE. Karpov, authorE. Diamanti, authorT. Debuisschert, authorN. J. Cerf, authorR. Tualle-Brouri, authorS. W. McLaughlin, et al., journalPhys. Rev. A volume76, eid042305 (year2007). OpenAlex ↗ · Scholar ↗
  18. authorB. Qi, authorL.-L. Huang, authorL. Qian, and authorH.-K. Lo, journalPhys. Rev. A volume76, pages052323 (year2007). OpenAlex ↗ · Scholar ↗
  19. authorT. Symul, authorD. J. Alton, authorS. M. Assad, authorA. M. Lance, authorC. Weedbrook, authorT. C. Ralph, and authorP. K. Lam, journalPhys. Rev. A volume76, pages030303 (year2007). OpenAlex ↗ · Scholar ↗
  20. authorS. Fossier, authorE. Diamanti, authorT. Debuisschert, authorA. Villing, authorR. Tualle-Brouri, and authorP. Grangier, journalNew J. Phys. volume11, pages045023 (year2009). OpenAlex ↗ · Scholar ↗
  21. authorT. Symul, authorV. Sharma, authorT. Ralph, and authorP. Lam, in booktitleOptical Fiber Communication Conference (organizationOptical Society of America, year2010). OpenAlex ↗ · Scholar ↗
  22. authorL. Madsen, authorV. Usenko, authorM. Lassen, authorR. Filip, and authorU. Andersen, journalArxiv preprint arXiv:1110.5522 (year2011). OpenAlex ↗ · Scholar ↗
  23. authorC. Weedbrook, authorS. Pirandola, authorR. García-Patrón, authorN. J. Cerf, authorT. C. Ralph, authorJ. H. Shapiro, and authorS. Lloyd, journalRev. Mod. Phys. volume84, pages621 (year2012). OpenAlex ↗ · Scholar ↗
  24. authorF. Grosshans and authorP. Grangier, journalPhys. Rev. Lett. volume88, pages057902 (year2002). OpenAlex ↗ · Scholar ↗
  25. authorP. Jouguet, authorS. Kunz-Jacques, and authorA. Leverrier, journalPhys. Rev. A volume84, pages062317 (year2011). OpenAlex ↗ · Scholar ↗
  26. authorA. Leverrier, authorF. Grosshans, and authorP. Grangier, journalPhys. Rev. A volume81, pages062343 (year2010). OpenAlex ↗ · Scholar ↗
  27. authorA. Winter, in booktitleIEEE Transactions on Information Theory (publisherIEEE, year1999), vol. volume45, p. pages2481. OpenAlex ↗ · Scholar ↗
  28. authorT. Ogawa and authorH. Nagaoka, in booktitleProceedings of IEEE International Symposium on Information Theory (organizationIEEE, year2002), p. pages73. OpenAlex ↗ · Scholar ↗
  29. authorA. Leverrier and authorP. Grangier, journalPhys. Rev. A volume83, pages042312 (year2011). OpenAlex ↗ · Scholar ↗
  30. authorN. Jain, authorC. Wittmann, authorL. Lydersen, authorC. Wiechers, authorD. Elser, authorC. Marquardt, authorV. Makarov, and authorG. Leuchs, journalPhys. Rev. Lett. volume107, pages110501 (year2011). OpenAlex ↗ · Scholar ↗
  31. authorA. Leverrier, authorE. Karpov, authorP. Grangier, and authorN. Cerf, journalNew J. Phys. volume11, pages115009 (year2009). OpenAlex ↗ · Scholar ↗
  32. authorA. Leverrier and authorP. Grangier, journalPhys. Rev. A volume81, pages062314 (year2010). OpenAlex ↗ · Scholar ↗
  33. authorV. Scarani and authorR. Renner, journalPhys. Rev. Lett. volume100, pages200501 (year2008). OpenAlex ↗ · Scholar ↗
  34. authorR. Filip, journalPhys. Rev. A volume77, pages022310 (year2008). OpenAlex ↗ · Scholar ↗
  35. authorV. C. Usenko and authorR. Filip, journalPhys. Rev. A volume81, pages022318 (year2010). OpenAlex ↗ · Scholar ↗
  36. authorY. Shen, authorX. Peng, authorJ. Yang, and authorH. Guo, journalPhys. Rev. A volume83, pages052304 (year2011). OpenAlex ↗ · Scholar ↗
  37. authorC. Weedbrook, authorS. Pirandola, authorS. Lloyd, and authorT. Ralph, journalPhys. Rev. Lett. volume105, pages110501 (year2010). OpenAlex ↗ · Scholar ↗
  38. authorC. Weedbrook, authorS. Pirandola, and authorT. Ralph, journalArxiv preprint arXiv:1110.4617 (year2011). OpenAlex ↗ · Scholar ↗
  39. authorJ. Lodewyck, authorT. Debuisschert, authorR. Tualle-Brouri, and authorP. Grangier, journalPhys. Rev. A volume72, pages050303 (year2005). OpenAlex ↗ · Scholar ↗