Elamur Research

CESTA: First Conclusions of the Technolangue MT Evaluation Campaign

Paper · 2006 · O. Hamon, A. Popescu-Belis, K. Choukri et al.

Summary

A translation can read smoothly while losing part of the original meaning. Another can preserve the information and still be difficult to read. CESTA, the French national evaluation campaign reported in this paper, asked how well people and automatic scores could distinguish these aspects of translation quality. The organizers tested systems translating from English and Arabic into French. They used general-domain documents first, then moved to health and medical texts and gave participants a chance to prepare for the new subject matter. The paper reports both the translation results and how closely the automatic measures agreed with human judgments. Its subject is the evaluation of machine translation.

The organizers collected several French translations of each test text. Automatic measures used these as references against which to compare system output. Human judges rated individual segments for fluency, meaning how well they read in French, and adequacy, meaning how much of the reference meaning they conveyed. The two human criteria gave the same ordering of the English-to-French systems within each campaign. The automatic measures agreed to different degrees, and their relative performance changed with the test material. On the general English-to-French collection, the weighted n-gram metric, WNM, had a correlation of 0.983 with human adequacy scores. On the medical evaluation, the reported correlation was 0.60. BLEU and NIST showed stronger associations with adequacy in the medical round than in the general round, while their associations with fluency weakened.

The medical evaluation also produced an unusually strong English-to-French result. One system received a human adequacy score of 0.882, above the 0.800 awarded to the official translation when both were judged against the selected agency translation. The authors found that the system had used some files from the site that supplied the test documents, and they also questioned how closely the official translation followed the source. Those circumstances make the result hard to interpret as evidence of general translation quality. The comparison across campaigns raised a related problem. Human scores suggested improvement for some returning systems, while automatic scores frequently declined. Because the test collections and parts of the protocol changed alongside the opportunity to adapt, the authors proposed testing the earlier system versions on the same medical documents. They also planned to release the corpora, translations and results so other evaluations could reuse the campaign materials.

Deep dive: CESTA: First Conclusions of the Technolangue MT Evaluation Campaign

CESTA compares human judgments and automatic scores for translations into French and examines what changes when systems adapt to medical texts. · about 31 minutes to read

The problem and its context

What should a translation evaluation measure?

CESTA evaluated translation by examining the French text a system produced. The organizers wanted a protocol that could be applied to commercial and academic systems and could support comparisons among them. Under the FEMTI guidelines cited in the paper, they concentrated on the quality of the output as a translation. That focus gave them a manageable question. Given a source text and a proposed French rendering, how much of the intended information comes through, and how well does the French read?

Adequacy and fluency answer different parts of that question. Adequacy concerns fidelity to meaning. A French segment can be awkward yet convey the information a reader needs. Fluency concerns readability and the quality of the French itself. Smooth phrasing alone gives a judge little evidence about information that has disappeared in translation. CESTA assigned separate scores to the two dimensions so the evaluation could capture these possibilities. A system's standing on one criterion was also something the researchers could compare with its standing on the other.

The paper connects this choice to the DARPA evaluations of the 1990s, which used fluency and adequacy as human assessment criteria. It also cites White's earlier work on the relationship between judgments of how intelligible a translation is and how faithfully it conveys the source. That relationship matters at different levels. If systems that preserve more meaning also tend to produce better French, the two criteria may put the systems in much the same order. A judge can still have good reasons to rate a particular sentence quite differently on the two criteria. The campaign's design left room to observe both kinds of relationship.

The reference translation is central to the adequacy judgment. In CESTA, judges compared the French meaning of a system segment with the French meaning of a corresponding reference segment. That procedure gives the evaluator a concrete text against which to judge meaning. It also makes the selection of a reference consequential. An official translation may have been produced for the originating organization and still take liberties that make it difficult to use as a yardstick for individual sentences. A commissioned translation can provide another rendering of the same source. The campaign's decision about which version to show the judges changed between rounds.

Why automatic metrics needed their own evaluation

The organizers also wanted a way to score output without having human readers evaluate every sentence. The paper describes automatic metrics already in use or under development. The best known in the campaign compare sequences of words in a candidate translation with sequences in reference translations. This gives a reproducible basis for comparison. Its relationship to the qualities a reader cares about remains an empirical question. Different French formulations can convey the same content, and a score derived from word matches responds to differences in wording even when a judge accepts both renderings.

The CESTA protocol drew on the NIST evaluation plan. Among the automatic approaches it examined were NIST's measure and a score originally developed at IBM and described in Bleu: a Method for Automatic Evaluation of Machine Translation.

The paper also discusses earlier work by Babych and Hartley on extending overlap-based evaluation with frequency weights. CESTA included their weighted n-gram metric alongside BLEU and NIST. The project also included experimental measures based on linguistic structure and preservation of semantic content. These brought different kinds of evidence into the evaluation. A score sensitive to the grammatical relationships in French output, for example, might behave differently from one that tracks sequences of matching words. Testing both on the same systems would show whether either produced comparisons compatible with those of human judges.

This comparison of measurements is what the authors call meta-evaluation. The translation systems are the objects being assessed in the main evaluation. In the meta-evaluation, the automatic metrics themselves become the objects of study. The researchers ask whether systems that score well by an automatic measure also tend to score well when judged by people, and whether the measure preserves the order that the judges give to the systems. The paper situates this question alongside earlier work on how to interpret automatic-score differences, including Interpreting BLEU/NIST Scores: How Much Improvement Do We Need to Have a Better System?.

Why the campaign changed domains

The project started in January 2003 under Technolangue and formed part of the EVALDA evaluation platform. Its initial campaign was intended to establish a common procedure for general-domain text. Systems were evaluated without a phase for adapting their terminological resources to the test domain. This matched the first objective of the project, which was to build a test procedure and apply it to existing systems on common material.

The next campaign introduced a specialized subject and a chance to prepare for it. In this setting, terminological enrichment meant adapting the resources a system uses for translation to health and medicine. The organizers disclosed the subject area and distributed material representative of it before the test. That gave participants an opportunity to improve their handling of domain-specific language. It also gave the organizers a second setting in which to study how the metrics behaved.

These goals create separate comparison questions. A change in domain is directly relevant when the question is whether a metric agrees with judges on different kinds of text. Estimating the effect of adaptation requires evidence about what the same system would have produced on the same kind of text before it adapted. The campaign provided a general round and a specialized round, with some systems participating in both. That design produced a cross-domain comparison and an opportunity to look for signs of improvement. The authors return to the distinction when they discuss what the resulting scores can establish.

The method, step by step

Build the source collections and prepare references

The campaign followed a common path from source documents to scored translations. The organizers selected documents and divided them into sentences, assembled French references, obtained system output, and then applied automatic and human assessments. They compared the resulting scores within each campaign. For the returning systems, they also looked across campaigns to see how the general and medical results differed.

How CESTA evaluates translations and checks its metrics

The steps in order.

How CESTA evaluates translations and checks its metricsStep 1: Select documents and divide them into sentences1. Select documents and divide them into sentencesStep 2: Prepare French reference translations2. Prepare French reference translationsStep 3: Issue domain material before the medical test3. Issue domain material before the medical testStep 4: Hide test documents among related source texts4. Hide test documents among related source textsStep 5: Collect the participating systems’ translations5. Collect the participating systems’ translationsStep 6: Score translations automatically against French references6. Score translations automatically against French referencesStep 7: Collect human fluency and adequacy judgments7. Collect human fluency and adequacy judgmentsStep 8: Compare scores and system rankings8. Compare scores and system rankings

Each direction had its own source collection. In the general campaign, the English material came from the Journal of the European Community. The Arabic material came from a UNESCO General Conference. In the medical campaign, the English documents came from Health Canada, and the Arabic documents came from the websites of organizations working in health and related areas. The document sources mattered both for setting the character of the task and for obtaining French translations already associated with the material.

The organizers segmented the collections at the sentence level. For human assessment, the unit described in the paper is a typographical sentence. Each candidate segment could then be associated with the segment or segments of French used for comparison. This setup puts the focus on local translation quality. A reader judging a unit of output can attend to whether its information is present and whether its French is readable. Document-level qualities such as consistency of wording across a long text fall outside what the reported sentence scores directly represent.

The source documents selected for testing were mixed into much larger collections of related material. In the general round, test documents were randomly distributed within masking corpora from the same lexical domain. The idea was to make the evaluation subset harder for developers to identify among the documents they received. Using surrounding material with similar vocabulary made topical clues less informative. The medical round again used masking corpora, in that case about ten times the size of the test collections. The general corpora used UTF-8 encoding and followed the NIST format.

For each test corpus, the organizers had four French references. One was the official translation from the organization that had produced the source. Translation agencies commissioned by CESTA supplied the other versions. Translation admits variation, so the collection offered several French renderings against which to compare the output. A candidate wording absent from one reference might be present in another. Using multiple translations gives a word-matching measure access to more of the variation that the campaign's translators actually produced.

The human procedure used a selected reference. In the general round, a linguist chose segments from the official rendition for the judges. The organizers treated that rendition as the authoritative version for the round. In the medical round, a linguist raised concerns about the quality of the official translation, and the judges used a selected agency translation. Automatic scoring retained the official version among its references. The official translation was also scored by the human judges in the medical round. It therefore had two roles in that round, depending on the procedure. It contributed a reference to the automatic assessment and served as an output that people could compare with the selected agency rendering.

Give participants a chance to prepare for the medical test

The specialized campaign added a stage before the test documents were distributed. The organizers told participants that the task would concern health and medicine. They supplied a training corpus for each direction representative of the material on which the systems would later be evaluated. This was the campaign's means of enabling domain adaptation. The systems could use the advance material to prepare their translation resources for the subject they would encounter.

The paper describes the data it supplied and the purpose of supplying them. It gives no shared recipe that every participant had to follow for adaptation. The preparation opportunity was common, while the details of how the systems used it belonged to the participants. For interpreting a reported score, the distinction is important. A medical-round result characterizes a submitted system as configured after it had an opportunity to prepare. The campaign's published scores do not separately identify the contribution of a terminology resource, a particular preparation decision or the system's existing capabilities.

The masking procedure and the preparation phase served different purposes. Advance notice and representative material made it possible to respond to the domain. Masking made it harder to tell which documents in the distributed material would determine the reported scores. The later discovery concerning Health Canada files illustrates where the latter safeguard ends. Mixing documents into a larger collection can conceal which pieces will be scored. The design cannot by itself establish whether a participant's earlier resources included material from the organization that supplied the test.

Ask judges about readability and meaning

The organizers built a web interface for collecting, storing and processing human assessments. The protocol assigned segments to judges at random. Each translated segment selected for evaluation was assessed by two judges for fluency and adequacy. The general-round design limited the number of segments assigned to each judge to a hundred to reduce fatigue. The limit treated the conditions of judging as part of the measurement. An evaluator faced with a long uninterrupted series of sentences could find it harder to maintain a consistent standard.

For fluency, judges used a 5-point scale. At its strongest end, the sentence read like French a native speaker might produce. At the weakest end, it was unintelligible. A judge considering fluency could attend to how readily the candidate sentence could be read and understood as French. The adequacy scale also had 5 points, but its endpoints concerned meaning. A top rating indicated that the reference meaning was fully present. A bottom rating indicated that the two rendered meanings had nothing in common.

The scales offer ordered judgments about a segment. The numerical results in the paper are reported as system scores, with one score for fluency and another for adequacy. These aggregates are the quantities used in the comparisons with automatic metrics. The article describes the response categories but does not give an equation for converting the segment ratings into the published system-level values. Consequently, a figure reported for adequacy can be read as the campaign's aggregate assessment on that criterion. It does not directly specify a percentage of facts, words or sentences translated correctly.

In the general round, the judges assessed fluency and adequacy together. In the medical round, the organizers ran them in separate stages. The change addressed a concern about influence between the judgments. If a reader thinks about fidelity and readability at the same time, an impression formed for one question may carry into the answer to the other. Separate stages were meant to reduce that possibility. The association between the criteria was still something the researchers measured after collecting the ratings.

Recruitment also affected the medical evaluation. The organizers reached only part of the output with human assessment because the supply of judges was limited. They sought judges from the medical domain, a decision that made sense given the specialized material. The paper treats human ratings as observations that can vary with the task and the people doing it. It therefore reports how closely the medical judges agreed as well as how each system scored.

Compute automatic scores from different kinds of evidence

The core automatic panel comprised BLEU, NIST, WNM, X-Score and D-Score. These measures produced a set of scores that could be placed alongside the human ratings. Their different inputs and emphases matter when interpreting agreement. The quantities come from distinct scoring rules, and each measure has its own scale. The paper describes the mechanisms at a conceptual level and reports settings and results. It gives no explicit equations for the campaign's metrics or correlations.

BLEU and NIST compare candidate text with references using an n-gram.

In this setting, an n-gram is a sequence of adjacent words. Single words can match even when their neighbors differ, while longer sequences capture some of the wording and order surrounding them. For the first campaign's reported BLEU and NIST results, the authors used cumulative 4-grams and ignored letter case. A difference in capitalization alone therefore did not prevent a match under that setting. The successive lengths in the comparison gave the measures evidence about individual words and longer runs of text. The score derived from the comparison is the BLEU score.

NIST is reported alongside BLEU because both use statistical comparisons of word sequences with references. The campaign treats them as distinct metrics and reports their results in separate columns. That matters when reading the scores. A NIST value and a BLEU value attached to the same output are expressed on different scales. Their usefulness for this study can be compared by examining their relationships to human ratings or the orders they assign to systems.

WNM combines ideas from BLEU and Legitimate Translation Variation. It weights words using frequency information computed with TF-IDF.

The weighting means matches can contribute differently depending on the words involved. TF-IDF combines information about how frequently a term occurs with information about its distribution across documents. In this campaign, the purpose of using such weights was to let frequency affect how much evidence a word contributes in an overlap-based assessment. The first campaign's WNM column reports its F-measure using the best reference translation. The paper does not specify the rule for selecting that reference or give the calculation for the reported F-measure. The results support comparisons under the stated setting.

The experimental X-Score examines how linguistic information is distributed in text. The paper mentions morphosyntactic categories, which distinguish grammatical types of words, and syntactic relations, which describe how words or phrases are linked in a sentence. These properties can provide evidence about how output is structured even when its words differ from the reference wording. X-Score also requires a learning corpus for its assessment of fluency. The organizers retained the same learning corpus when moving to the medical test. That decision later became relevant to how the authors interpreted the metric's performance.

D-Score is meant to measure how well the semantic content of a text survives translation. CESTA could therefore ask whether a metric with that objective agreed with adequacy ratings from people who compared meanings. The paper gives the intended property and the observed scores, with no detailed derivation of the measure. Its empirical comparison is informative on its own. Agreement between the D-Score values and the human ratings is something the campaign tests.

The researchers also used mWER and mPER internally. The former is a word-error measure that can use multiple references. The latter is a multi-reference word-error measure that disregards word positions. The paper introduces them as additional points of comparison, drawing on measures used more frequently in automatic speech recognition. The main system results and meta-evaluation tables concern the core panel, with no comparable set of published results for the internal measures.

Compare score values and rankings

The organizers examined agreement in two ways. They reported Pearson correlations between automatic scores and the human scores for fluency and adequacy. Pearson correlation describes the direction and strength of a linear association. If stronger automatic scores generally accompany stronger human scores, the correlation is positive. If higher values of the automatic metric accompany lower human scores, it is negative. This description concerns how the scores vary together and leaves questions of absolute calibration open.

The other comparison used system ranks. A rank places a system ahead of or behind the other participants according to a given criterion. Working with ranks allowed the authors to compare the standings produced by metrics whose raw values differ greatly in scale and are hard to interpret as absolute quantities. It also makes certain disagreements easy to see. An automatic score can favor a system that judges put lower, or it can reverse the order of two systems the judges put near each other.

The score correlations and ranking comparisons address different features of the evaluation. A metric may pick out a very strong system but order the others differently from human judges. A ranking also gives the same kind of position change to cases where scores are close and cases where they are far apart. The paper reports both views so readers can see whether apparent agreement comes from a shared ordering, a similar pattern in score values or a conspicuous result for a particular participant.

Experiments and results

The general-domain campaign

The general round included five English-to-French systems and two Arabic-to-French systems. The Journal of the European Community was the source of 15 documents in the English collection. The Arabic collection contained 16 documents from the UNESCO 32nd General Conference. Each test corpus contained around 20,000 source words. The masking collections contained some 200,000 words from the corresponding lexical domain. Each direction therefore supplied a common set of source documents on which to compare the participants translating into French.

The systems competed as anonymous entries in the results. The comparisons have two main sets of benchmarks. Within each direction, the other participants provide a point of comparison on the same input. For the meta-evaluation, the human assessments provide the comparison standard for the automatic measures. The official translation appears as a separately scored human benchmark in the medical round. In the published general-round results, the French references support scoring and the human-score rows are for the participating systems.

On general English-to-French text, System 4-EN led on both human measures. Its fluency score was 0.511, followed by System 5-EN at 0.503. System 3-EN had the weakest fluency score, 0.353. The chart gives the corresponding adequacy comparison. The same entries occupy the leading and trailing positions, and the whole order matches the fluency order.

Human adequacy on the general English-to-French test

Human judges placed System 4-EN first and System 5-EN next.

Human adequacy on the general English-to-French testSystem 4-EN (this paper): 0.636System 4-EN (this paper)0.636System 5-EN: 0.608System 5-EN0.608System 1-EN: 0.561System 1-EN0.561System 2-EN: 0.545System 2-EN0.545System 3-EN: 0.489System 3-EN0.489
The numbers
System or settinghuman adequacy score
System 4-EN (this paper)0.636
System 5-EN0.608
System 1-EN0.561
System 2-EN0.545
System 3-EN0.489

The Arabic-to-French human scores distinguish the two entries in the same direction on each criterion. System 1-AR received 0.198 for fluency and 0.310 for adequacy. System 2-AR received 0.083 for fluency and 0.166 for adequacy. These are results for the participating systems on the Arabic source collection. The English and Arabic directions used different documents and separate pools of participating systems, so their scores describe different tasks even though both produce French.

BLEU and NIST placed System 5-EN first on the general English text. It received 0.572 on BLEU and 11.025 on NIST. System 4-EN, favored by the human judges, received 0.450 and 9.808 on the corresponding metrics. The automatic measures also favored System 2-EN more than the judges did. Its BLEU score, 0.465, and NIST score, 9.964, put it ahead of System 4-EN on both automatic measures. WNM gave System 4-EN an F-measure of 0.692 and System 5-EN an F-measure of 0.691, preserving the order the judges gave to those entries. Its ranking across the English systems matched the human rankings.

Agreement was more varied for the experimental metrics. X-Score gave the top English value to System 5-EN at 0.420 and assigned 0.418 to System 4-EN. It tracked the human judgments closely overall in spite of its different choice of leader. D-Score had a negative association with both sets of human scores. The first-round Arabic results also contain examples of metric disagreement. BLEU and NIST each put System 1-AR ahead of System 2-AR, in line with the judges. The reported WNM F-measures were 0.493 for System 1-AR and 0.515 for System 2-AR, placing them in the opposite order when read from highest value to lowest.

The paper reports first-round score correlations for English-to-French. The fluency comparison below shows that WNM had the strongest positive association with human scores, with X-Score also comparatively high. For adequacy, the corresponding Pearson correlations were 0.62 for BLEU, 0.65 for NIST, 0.983 for WNM, 0.95 for X-Score and -0.82 for D-Score. The negative signs for D-Score describe how the published metric values vary with human scores. The authors refer to separate work for an explanation of the inverse relationship.

Automatic metrics and human fluency on the general English-to-French test

WNM had the strongest positive association with human fluency, and D-Score varied inversely with it.

Automatic metrics and human fluency on the general English-to-French testWNM F-measure (this paper): 0.994WNM F-measure (this paper)0.994X-Score: 0.93X-Score0.93NIST: 0.71NIST0.71BLEU: 0.68BLEU0.68D-Score: -0.81D-Score-0.81
The numbers
System or settingPearson correlation with human fluency
WNM F-measure (this paper)0.994
X-Score0.93
NIST0.71
BLEU0.68
D-Score-0.81

The ranking comparison gives a concrete account of some of these associations. BLEU and NIST both moved System 2-EN from fourth in the human rankings to second in their rankings. Both also reversed the relative standing of Systems 4-EN and 5-EN. WNM agreed throughout with the human ordering, and X-Score came close. The authors read these findings as evidence that WNM and X-Score were promising for French output under this protocol. The medical round gave them a way to see how far the pattern would carry over when the test material changed.

The medical collections and judging sample

Five English-to-French systems took part in the medical round. There was one Arabic-to-French entry. Some participants returned from the first campaign and others changed, with four English-to-French systems available for comparison across rounds. The changes in participation matter when reading rankings. Each ranking gives an entry's position within the set evaluated on that occasion.

Health Canada supplied the 16 documents in the English collection. The Arabic collection had 30 documents drawn from UNICEF, the World Health Organisation and Family Health International. Both collections contained about 20,000 source words each. The English test set had 917 segments, while the Arabic test set had 824. The segmentation gave the organizers a common unit of output for the automated tests and for selecting material for human evaluation.

The authors report that human judges assessed about a third of each system's output in this round. There were 4,608 evaluated segments, 48 judges and 96 segments per evaluator as reported in the protocol description. These figures describe the judging workload and the coverage of the assessment. The selected agency translation was the reference for human ratings. The organizers also evaluated the official translation, allowing its fluency and adequacy scores to appear next to the system results.

Human scores on the medical text

One English-to-French system was clearly ahead of the other system entries on both human measures. System 2-EN received 0.821 for fluency, compared with 0.888 for the official English-to-French translation. Its adequacy score was 0.882. The chart shows that the official version received a lower adequacy score in the same evaluation. Both were assessed with the selected agency translation as the reference for meaning.

Human adequacy on the medical English-to-French test

System 2-EN led the system entries and scored above the official translation against the selected agency reference.

Human adequacy on the medical English-to-French testSystem 2-EN (this paper): 0.882System 2-EN (this paper)0.882Official human translation: 0.800Official human translation0.800System 3-EN: 0.609System 3-EN0.609System 1-EN: 0.596System 1-EN0.596System 4-EN: 0.557System 4-EN0.557System 5-EN: 0.460System 5-EN0.460
The numbers
System or settinghuman adequacy score
System 2-EN (this paper)0.882
Official human translation0.800
System 3-EN0.609
System 1-EN0.596
System 4-EN0.557
System 5-EN0.460

The remaining English systems give a useful sense of the shape of the results. The fluency scores for Systems 3-EN, 1-EN and 4-EN were 0.575, 0.547 and 0.543, respectively. System 5-EN scored 0.320 on fluency and came last among the system entries on adequacy as well. The fluency and adequacy rankings remained identical among the systems. The official human translation changes the picture if it is included in the ordering, because it led the system entries on fluency and fell behind System 2-EN on adequacy.

The authors consider several reasons for the unusually high result. Health Canada's official French translation may have been judged weak or may have rendered the source more freely than the agency reference did. The evaluators may consequently have found the system's rendering closer in meaning to the chosen reference on more occasions. The authors also learned that System 2-EN had incorporated some Health Canada files into its setup data. That raises the possibility that familiarity with material from the test source boosted its score. The paper leaves the relative contributions of these explanations unresolved.

The Arabic-to-French result gives a particularly clear example of why the two human criteria were worth keeping. System 1-AR received 0.015 for fluency, while the official Arabic-to-French translation received 0.926. On adequacy, the corresponding scores were 0.426 for the system and 0.628 for the official translation. The authors interpret this as evidence that the system communicated a substantial part of the content while producing French that judges found severely deficient in readability and style. With only one participating Arabic-to-French system in this round, the observation concerns that entry and its comparison with the official translation.

For the medical judgments, the reported inter-rater correlation was 0.637 for adequacy and 0.585 for fluency. These coefficients describe how the scores from different raters moved together for each criterion. The reported correlation between fluency and adequacy judgments was 0.386, which the authors characterize as low compared with what they had seen in the general round. This can coexist with identical rankings of the English systems on the aggregate scores. The rank comparison asks which system tends to do better overall. The relationship between judgments concerns variation within the ratings that contribute to those aggregates.

Automatic scores on the medical text

BLEU and NIST also singled out System 2-EN. It scored 0.896 on BLEU and 14.395 on NIST. System 5-EN had the weakest scores among the English entries under both measures, 0.339 and 8.454. Systems 1-EN, 3-EN and 4-EN formed a group between these endpoints. The automatic metrics and the judges could therefore pick out the same conspicuously strong and weak entries while ordering the middle group differently. System 4-EN, for example, had the highest BLEU score in that middle group at 0.398, while System 3-EN led the group on human adequacy.

In the medical round, the table of score correlations gives BLEU 0.59 with fluency and 0.79 with adequacy, and NIST 0.55 with fluency and 0.75 with adequacy. The paper describes both metrics as more closely associated with adequacy than they had been in the general campaign, with weaker associations for fluency. Its English system ranking comparison also gives BLEU and NIST a rank correlation of 0.7 with the shared human ordering. In this round the two measures were better aligned with the human ordering than the other automatic metrics studied.

The medical table reports WNM correlations of 0.63 with fluency and 0.60 with adequacy. This was a clear reduction from the near-perfect positive associations reported on the general English test. The English rank comparison gives WNM a correlation of -0.7 with the human ordering. These figures describe different comparisons. The published score correlations retain the values generated by the metric, while the ranking result compares the order of the English entries. The WNM ranking put System 2-EN last among those entries, despite its first place with the judges.

X-Score also changed markedly between rounds. The medical results report correlations of -0.17 with fluency and -0.22 with adequacy. D-Score had correlations of -0.25 with fluency and -0.02 with adequacy. These medical associations are weak by the paper's account. For X-Score especially, this differs from its close association with human ratings in the general campaign. The authors consider whether the scores reflect aspects of translation quality that their human criteria captured only partly. In the case of X-Score, they also point to the learning corpus as a possible source of the change.

What the ablations show

The paper reports no component ablations, and its main analyses compare metric agreement across test settings and track the systems that returned for the medical round.

What changes when agreement is measured by ranks

The rank analysis shows where judging an automatic measure by a broad association can leave out important information. In the general round, BLEU and NIST agreed with one another and correctly placed System 3-EN at the bottom among the English entries, as judged by people. Both gave System 2-EN a much more favorable position and switched the order of the strongest entries. If the measurement is being used to choose a winner, the switch between Systems 4-EN and 5-EN changes the decision. If the purpose is to identify a clear trailing system, the same ranking can still be helpful.

WNM offers a useful contrast between campaigns because its general-round ordering matches the human one and its medical-round ordering diverges markedly. On the general test, the frequency-weighted approach produced system comparisons that were especially close to those of the judges. On the specialized test, it gave System 2-EN the lowest English rank even though that system stood apart in the human results. The comparison establishes a change in agreement under the two campaign conditions. The paper leaves the cause of the WNM change open. Its experiments do not vary the weighting rule while holding the evaluated translations and references fixed.

The medical treatment of BLEU and NIST also shows why the type of agreement matters. Both improved in the paper's comparison of rankings between campaigns. Their reported score correlations with adequacy strengthened, while their correlations with fluency weakened. The effect of moving to a new test therefore depends on which judgment serves as the benchmark and how agreement is expressed. A measure can become better at reproducing the relative standing of systems while showing less association with a particular set of human scores.

Whether the experimental scores travel across domains

The X-Score comparison raises a question about the data a metric itself needs. In the general round, its scores and human ratings moved together strongly. In the medical round, the relationship weakened and the reported coefficients became negative. The metric relied on a fluency learning corpus that was kept from the earlier evaluation. The authors suggest that the grammar of texts in different domains may be expressed through different distributions of linguistic relations. On that account, a reference for what fluent output looks like in one collection could become less suitable when the subject matter and texts change.

That is a hypothesis about why X-Score behaved differently. The paper does not compare X-Score trained on general material and X-Score trained on medical material on the same outputs. Such a comparison would address the role of the metric's learning corpus more directly. The reported evidence instead records the outcome when the test domain changed and the learning corpus stayed the same. The findings justify uncertainty about carrying the general-round agreement into the medical setting.

D-Score shows a different pattern. Its general-round correlation with human ratings was strongly inverse. Its medical-round associations were much weaker. The authors suggest that the experimental metrics may respond to qualities that the fluency and adequacy scales capture differently. The distinction between an intended measurement and its observed behavior matters here. D-Score is designed around semantic preservation. The campaign results tell a reader how its values were associated with judged adequacy on these collections, without showing which particular semantic changes the metric recognized or missed.

What the returning systems say about adaptation

The paper uses lettered identifiers for the four English-to-French systems that participated in both campaigns. The numerical identifiers used for the separate rounds differed, so the lettered labels let readers follow the same participants across the general and medical tests. This improves one aspect of the comparison. A change in score can be attached to the same participant, even though the texts, evaluation conditions and opportunity for preparation changed.

For System A-EN, human fluency rose from 0.459 on the general test to 0.547 on the medical test. Human adequacy rose from 0.561 to 0.596. BLEU moved from 0.438 to 0.378, and X-Score from 0.407 to 0.387. The same participant thus received more favorable human ratings in the medical round and lower scores under both of the automatic measures shown in the cross-campaign analysis. Its results illustrate how the two assessments can tell different stories about a move between corpora.

For System B-EN, human fluency went from 0.419 to 0.821 and human adequacy from 0.545 to 0.882. BLEU rose from 0.465 to 0.896, while X-Score moved from 0.394 to 0.352. This is the participant that stood out as System 2-EN in the medical round. Human and BLEU results agree about its strong showing there, but the setup data from Health Canada complicate any claim about the reason for its improvement. Its X-Score also illustrates the larger decline in agreement between that measure and the human ratings.

Systems C-EN and D-EN gained on human fluency across rounds while losing ground on human adequacy. For C-EN, the fluency values were 0.511 and 0.575, and the adequacy values were 0.636 and 0.609. For D-EN, the fluency values were 0.503 and 0.543, and the adequacy values were 0.608 and 0.557. BLEU and X-Score each declined for both participants in the paper's cross-campaign comparison. These results qualify any broad description of better human-assessed quality. The increase appears across the returning systems for fluency, while adequacy shows mixed changes.

The point of the analysis is to see what might be attributable to the opportunity to adapt terminology. The results compare different genres and subject areas, so a score can change because the texts differ or because a measurement behaves differently on them. Even the human procedure changed its reference selection and separated the assessment stages. The authors therefore proposed a further round that would translate the medical test with the versions of the systems from before adaptation. That comparison would put the earlier and adapted versions on the same source text and make the effect of preparation easier to assess.

Limitations

Limits identified by the authors

The principal limitation is the absence of a medical test result for the corresponding pre-adaptation versions. The comparison across campaigns controls for the identity of some participants. It leaves the domain, genre and particular test items free to vary. The authors point to the different nature of the corpora as a likely explanation for the declining automatic scores across much of the comparison. They say the proposed test of the earlier versions on the medical data lay beyond the scope of CESTA. The paper consequently reports evidence about performance under each campaign's conditions and a provisional account of what might explain the differences.

The strong result for System 2-EN has unresolved sources. The authors question whether the Health Canada official translation was suitable as a comparison and suggest that greater freedom in its phrasing may have affected its adequacy ratings against the selected agency translation. They also flag the Health Canada files in the system's setup. They establish the presence of some files from the site in that setup, while leaving their exact overlap with the evaluated documents and their effect on the scores unresolved. The reported scores support the claim that the system did exceptionally well in this test. A claim of comparable performance against human translations in general would require a broader basis.

The authors also recognize limitations in the human evidence. Limited availability of judges reduced the amount of medical output they could cover. The reported inter-rater correlations indicate imperfect agreement, with fluency proving the less closely aligned of the two human criteria. The paper suggests that the medical material may have been harder to evaluate. It also allows that the medical background sought in the judges might have affected their linguistic assessments. The reported results do not isolate the effects of the subject matter, the makeup of the judging pool or the separation of fluency and adequacy into stages.

For the experimental metrics, the paper explicitly calls for further study. A medical fluency corpus for X-Score was an objective for future work. The study did not establish how much such a corpus would improve its agreement with human judgments. The authors also leave WNM's loss of agreement in the medical test for further analysis. These open questions limit any general ordering of the metrics by reliability. The general and medical results describe performance on particular material under the protocol used for each.

The authors are cautious about the Arabic-to-French medical data because the round had a single participating system in that direction. The gap between that system's fluency and adequacy assessments is informative about its output. The design provides little basis for comparing the behavior of automatic metrics across several Arabic-to-French systems in the medical domain. The first campaign's reported correlations were restricted to the English-to-French direction. The evidence about metric agreement for French output is therefore concentrated in that direction.

Limits that follow from the setup

The human and automatic procedures use human translations in different ways. The automatic metrics had several French references available. The human judges used a selected reference for adequacy, and in the medical round the official translation itself was assessed against the agency rendering. A wording choice can consequently meet different conditions in the two procedures. An automatic metric can encounter a matching phrase among its references, while a judge considers whether the meaning in a particular selected reference survives. Because the paper gives no comparison that holds the reference set constant across these procedures, the effect of this difference on their agreement is unresolved.

The human criteria also rely on the chosen unit of evaluation. A typographical sentence allows a judge to focus on a clear segment and lets the organizers spread the work among evaluators. The resulting scores characterize individual pieces of output aggregated for a system. The design does not separately assess whether a translation uses a term consistently throughout a document, preserves connections between sentences or suits the communicative purpose of the document as a whole. These are boundaries of the evidence the campaign gathered, especially when health documents are considered as texts that someone might use rather than as collections of rated segments.

Agreement measures are sensitive to the systems included in the comparison. A small group of nearly tied entries and a very strong entry produce a different pattern of score variation than a set of evenly spread results. The outlying medical result for System 2-EN is particularly relevant. An automatic measure that also gives that entry a very high score may track a conspicuous part of the human pattern while differing on close comparisons. The rankings help show where those disagreements occur. The paper gives no uncertainty intervals for the metric correlations or analysis of how those correlations change when the leading system is omitted. The reported values are therefore best understood as summaries of the available comparisons.

The specialized campaign also changes several conditions at once. Participants could prepare for the domain, the source collections changed, the participant pool shifted, the human reference policy was revised and the two rating criteria were assessed in separate stages. The paper's cross-campaign comparisons record what happened under these combinations of conditions. They cannot assign the change in a metric's agreement to a particular decision. That applies both to the proposed explanation for X-Score and to any claim that changes in the human procedure caused the different relationship between fluency and adequacy.

Finally, the published protocol gives more detail about the evaluation design than about some of the scoring calculations. The paper describes what the metrics are meant to measure, identifies settings such as case-insensitive 4-grams, and reports the results that enter its analysis. It does not specify every step needed to reconstruct the human aggregates or the experimental scores independently. The authors' plan to release the corpora, translations and results addresses part of that practical issue. The paper reports the release as a plan, so the announcement establishes what the organizers intended to make reusable.

What came after

A later paper that cites CESTA is MEDAR, published in 2008. Its stated subject is collaboration between European and Mediterranean Arabic partners to support the development of Arabic language technology. The connection to CESTA is clearest in the language coverage. CESTA included Arabic as a source language in both campaigns and gathered source documents, French references, system translations and judgments for evaluation. MEDAR places Arabic language technology in the broader setting of collaboration among partners. The citation establishes that CESTA was part of that later work's background. It leaves open whether MEDAR reused the corpora, adopted the scoring protocol or extended any of the metric comparisons. MEDAR

CESTA itself identifies what the authors intended to carry forward. They planned for ELDA to release an evaluation package including the corpora, reference translations and results. They envisaged a platform on which developers could evaluate systems, and they described further medical testing that would put adapted and earlier system versions on common material. Those plans concerned different aspects of the campaign. The package would preserve the material and observations from the evaluations. The additional test would answer the narrower question of whether preparation for the medical domain improved translation on the medical documents. The paper ends with that empirical question still open.

Cite

Cite as O. Hamon, A. Popescu-Belis, K. Choukri, M. Dabbadie, A. Hartley, W. Mustafa El Hadi, M. Rajman and I. Timimi. 2006. CESTA: First Conclusions of the Technolangue MT Evaluation Campaign. Proceedings of the Fifth International Conference on Language Resources and Evaluation (LREC'06).

The paper itself, not this page. BibTeX from the library's record of the work.

@inproceedings{hamon2006cesta,
  title = {{CESTA: First Conclusions of the Technolangue MT Evaluation Campaign}},
  author = {O. Hamon, A. Popescu-Belis, K. Choukri, M. Dabbadie, A. Hartley, W. Mustafa {El Hadi}, M. Rajman and I. Timimi},
  booktitle = {Proceedings of the Fifth International Conference on Language Resources and Evaluation (LREC'06)},
  year = {2006},
  doi = {10.63317/496w2arxrd65},
  url = {https://doi.org/10.63317/496w2arxrd65}
}

↑ back to top

This page in Markdown https://md.research.elamur.ai/free/en/papers/hamon-2006-cesta-first-conclusions-technolangue-mt/