Summary

A knee MRI can reveal a torn ligament or meniscus without surgery, but interpreting an exam means examining many images of the same joint from different directions. Even experienced readers can reach different conclusions. The authors built MRNet to flag abnormal knee MRI scans and detect meniscal tears and tears of the anterior cruciate ligament (ACL), two findings that often influence clinical decisions. They asked whether the system could make useful predictions by itself, whether it could recognize ACL injuries at another hospital, and whether showing its predictions to clinicians changed how they read the scans.

The Stanford dataset comprised 1,370 exams. MRNet learned from the images and diagnoses recorded in the original clinical reports. It processed each imaging series slice by slice, kept the strongest response across slices for each learned feature, and used those responses to score the series. A separate calculation combined scores from the sagittal, coronal, and axial series into an exam-level result for each finding. Using the majority vote of musculoskeletal radiologists as the reference for 120 held-out Stanford exams, the authors obtained an AUC of 0, where AUC denotes the area beneath the receiver operating characteristic curve.937 for abnormality, 0.965 for ACL tears, and 0.847 for meniscal tears. AUC measures how well a score separates positive from negative exams across possible decision thresholds. At the threshold used for hard decisions, unassisted general radiologists detected more reference-positive ACL tears and were better at recognizing exams without meniscal tears.

The authors then had general radiologists and orthopedic surgeons read the same Stanford exams with and without seeing MRNet’s probabilities. Access to the scores improved ACL tear specificity by a mean of 0.048. The clinicians more frequently correctly called an exam negative when the specialist reference indicated no ACL tear. This was the only improvement to remain statistically significant after adjustment for multiple comparisons. The stand-alone system produced all classifications for the internal validation set in under 2 minutes, while the clinicians took more than 3 hours on average to complete their reviews. Those timings describe different tasks: generating scores for the study findings and reading the clinical images.

At Clinical Hospital Centre Rijeka, a Stanford-trained sagittal classifier achieved an ACL injury AUC of 0.824 on 183 held-out exams without additional training. Training on Rijeka data raised the AUC on that same held-out set to 0.911. The findings show that useful image cues carried across hospitals and that local training made a difference in this setting. The study used retrospective exams, had a small reader panel, and relied on specialist interpretation as the internal reference without consistent surgical confirmation. Its evidence for clinical assistance concerns how clinicians classified scans during the reading experiment. Effects on treatment decisions and patient care remained open.

Deep dive: Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet

MRNet reads knee MRI scans for abnormalities and tears, with tests of its accuracy at two hospitals and its effect on clinicians’ readings. · about 34 minutes to read

The problem and its context

What makes a knee MRI difficult to read

Knee MRI has an established place in evaluating disorders of the joint. The clinical studies discussed by the authors found that MRI can identify problems involving the menisci and cruciate ligaments and help clinicians decide who might benefit from surgery. Imaging can also help rule out an injury without an invasive procedure. This makes interpretation consequential in both directions. A missed tear can leave a clinically important finding unrecognized. An incorrect tear diagnosis can prompt further investigation of an injury the patient may never have had.

The image record is much larger than the diagnostic statement it eventually supports. A single exam contains series acquired in different planes, with each series covering the joint in successive slices. Acquisition choices affect how tissues and abnormalities appear. A reader may see a suspicious region on one slice, inspect neighboring slices for evidence that it continues, and consult another view to understand its shape. Even specialists can disagree with each other or change their own assessment when they revisit an exam. An automated reading aid therefore had to contend with both the size of the image input and the variability in the judgments used to evaluate it.

The paper distinguishes broad screening from identifying a particular tear. The broad question is whether the exam shows any abnormality. The narrower questions concern tears of the ACL and menisci. An exam can answer yes to several questions at once, while a fracture, effusion, or other finding can make an exam abnormal without either target tear. This arrangement lets the authors ask whether a common processing scheme can learn focused signs of injury as well as the more varied signs that separate an abnormal exam from one read as normal.

There is also a distinction between what the images show and what a clinician might do next. The system was designed to produce classifications from images. An orthopedic decision can involve much more than those classifications, and the paper’s study of assistance focused on the reading task. For that task, the clinician has a concrete decision to make about each finding and can assess a probability alongside the images. This creates an opportunity to test assistance directly by varying what information the reader has while keeping the exam itself fixed.

Where earlier automation left off

As the authors describe the field, traditional image analysis had limited applicability to knee MRI because the images span multiple dimensions and planes. A method designed around a prespecified appearance must contend with how that appearance changes across slices and views. Deep learning offered a way to learn successive stages of image representation from examples. Earlier stages can respond to relatively simple patterns, and later ones can combine those responses into information pertinent to a task. The paper situates that approach within machine learning.

The authors point to work on classifying skin cancer and detecting diabetic retinopathy and lung nodules as prior successes of deep learning in medical imaging. Those examples supported trying learned image features in a new setting. They did not settle how to process a stack of knee slices or how to use evidence from distinct MRI series. The paper also cites work on understanding the features learned by image networks, an issue it revisits through overlays that show influential image regions. Visualizing and Understanding Convolutional Networks

Earlier deep learning on knee MRI, as described by the authors, concentrated on cartilage. One line of work segmented cartilage, meaning that it tried to identify which parts of an image belonged to that tissue. Another line detected cartilage lesions. MRNet’s question is posed at the exam level. It takes image series as input and produces a probability for a finding, with supervision supplied at the level of the exam. That design fits labels recovered from clinical reports, which can record the presence of a tear without marking its location on every image.

The paper also draws on an earlier semi-automated study of ACL injury by Štajduhar and colleagues. That work provided an opportunity to test a narrower question across institutions. Its data concern ACL injury and contain a sagittal series. The study at Stanford could therefore test whether a classifier learned from its own sagittal images retained discriminatory value at Rijeka, and what happened when the same approach learned from Rijeka examples. Transfer of the complete Stanford system, including its combination of planes and its other targets, would have required a different external dataset.

Why measure assisted reading separately

A stand-alone comparison answers whether an automated score can support a classification with a chosen threshold. Clinical assistance involves an additional step. A person has to decide what weight to give that score, particularly when it disagrees with the image interpretation. A high AUC is compatible with help, indifference, or a tendency to follow the score into errors. The authors therefore tested predictions as information given to readers as well as predictions converted directly into decisions.

The prospect motivating this distinction was practical. An automated score might help a radiology service order its worklist, or it might provide a second opinion when a specialist is unavailable. Reordering a queue and helping a clinician review an exam are different uses. The first acts before the interpretation. The second acts within it and can change a decision even if the exam reaches the reader at the same time. The paper investigates the second through an assisted-reading experiment and discusses the first as a possible clinical application.

The method, step by step

From clinical reports to learning examples

The authors began with knee MRI scans that Stanford University Medical Center performed between 1 January 2001 and 31 December 2012. They manually reviewed the reports to assemble 1,370 exams and extract labels from the reported findings. Common reasons for imaging included pain, trauma or injury, follow-up, and evaluation before surgery. The cohort reflects examinations ordered through clinical practice, with cases drawn from several kinds of referrals rather than assembled around a single symptom.

An exam is the unit that receives labels. The input images for that exam are arranged into series, and the computational pipeline can learn from each selected series separately. The same exam may have both a torn ACL and a torn meniscus. The authors trained separate predictors for the different findings, so a high score for one never forces the score for another to be low. This matters for both training and evaluation. Each prediction has its own positive and negative examples even though the exams are shared.

The original reports supplied labels for fitting and tuning. The internal validation exams had a second set of labels produced by specialist review. The distinction is important because the network learned from conclusions made as part of ordinary care, while the main internal results judge its scores against a dedicated reference reading. The paper reports both sources of labels for the validation set. The resulting counts differ because the original report and a later specialist majority can disagree about a finding.

The Stanford data were divided into a training set of 1,130 exams, a tuning set of 120 exams, and an internal validation set of 120 exams. Exams from the same patient were assigned to the same split. This avoids a situation where an exam from a patient helps to fit the network and another exam from that patient is then treated as independent validation. The authors used stratified random sampling to put at least 50 positive examples for each target in both tuning and validation. They could then compare predictions on enough positive exams for each diagnosis, including ACL tears, which occurred less often in the full dataset than general abnormalities.

The roles of the splits are distinct. Training examples supply the image and label pairs from which the parameters are learned. The tuning examples determine which saved version of a classifier to retain. The internal validation examples are used after that selection to assess the fitted system and conduct the reader study. Giving the tuning set an explicit role matters when training produces many possible versions of the same network. The loss can keep falling on familiar training images after the best version for unfamiliar images has already appeared.

Preparing the imaging series

Stanford used GE scanners and a routine knee protocol without contrast. The authors chose sagittal T2-weighted, coronal T1-weighted, and axial proton density (PD) series from that protocol. These series provide different viewing directions and different contrasts. Sagittal images show the knee from the side, coronal images show it from the front or back, and axial images cut across the limb. The sequence name identifies how the scan was acquired and how tissues are emphasized. Within the selected series, the number of slices ranged from 17 to 61, with a mean of 31.48 and an SD of 7.97.

The pipeline took the images out of their Digital Imaging and Communications in Medicine files, commonly called DICOM files. It resized each image to 256 × 256 pixels and converted the images to Portable Network Graphics format. Standardizing the pixel dimensions makes it possible to pass each slice through the same image network. The series can still contain different numbers of slices. MRNet accommodates that variation later, when it condenses the slice features into a representation of fixed size.

Intensity also required attention. A numeric pixel value need not have the same meaning in every MRI series. The authors applied a histogram-based standardization procedure, which uses how often different intensities occur to align the image scale. They estimated a representative intensity distribution for each series type using the training exams. Parameters learned from that distribution were then applied to training, tuning, and validation images. The intention was to make similar tissue correspond to more comparable intensities across exams. Values outside the PNG range were clipped to 0 or 255.

The ordering of these operations matters. The reference distribution is derived during training and then applied to held-out cases as a fixed transformation. A new exam can consequently be processed on its own using the existing parameters. The preprocessing also sets the inputs apart from those used by the readers. MRNet saw prepared images from selected series, while the reader study took place in a clinical viewing system using the original DICOM images.

How MRNet scores a Stanford knee MRI exam

The steps in order.

How MRNet scores a Stanford knee MRI examStep 1: Extract selected series from the clinical images1. Extract selected series from the clinical imagesStep 2: Resize slices and standardize their intensities2. Resize slices and standardize their intensitiesStep 3: Extract feature maps from each slice3. Extract feature maps from each sliceStep 4: Average each map across image positions4. Average each map across image positionsStep 5: Keep each feature’s strongest slice response5. Keep each feature’s strongest slice responseStep 6: Convert features into a probability per series6. Convert features into a probability per seriesStep 7: Combine series probabilities for each finding7. Combine series probabilities for each finding

Turning a stack of slices into a score

MRNet is a convolutional neural network that operates on one series for one target at a time. A convolutional network learns filters that respond to patterns in the image and applies them at different image positions. As images pass through successive layers, the network represents them with feature maps. Each map expresses how strongly a learned pattern responds at locations within the slice. The maps are numerical intermediate results, so a channel need not correspond to a feature that a radiologist would name.

The input series has the following shape.

s × 3 × 256 × 256

Here s is the number of slices in the series. 3 is the number of image channels in the network input, consistent with the image representation expected by the feature extractor. Both instances of 256 refer to pixel dimensions, one for image height and the other for image width. The multiplication signs separate dimensions of an array.

The authors used an AlexNet feature extractor on each slice. Its output for the entire series has this shape.

s × 256 × 7 × 7

Here s again counts slices. 256 now counts learned feature maps for each slice. The two 7 dimensions describe the height and width of a feature map. Each slice has its own maps, produced with the same feature extractor. The maps have coarser spatial resolution than the original image, but their spatial arrangement still makes it possible to see where a response arose.

The first pooling operation averages each feature map over its spatial positions. Pooling takes many values and summarizes them with fewer. In this operation, the average gives a single value for one learned feature on one slice. The following notation expresses the operation described in the paper.

aᵢₖ = meanᵤ,ᵥ Fᵢₖᵤᵥ

Here i indexes a slice, k a learned feature channel, and u and v a row and column on that channel’s map. Fᵢₖᵤᵥ is the feature response at that location. meanᵤ,ᵥ averages over the map’s row and column positions. aᵢₖ is the resulting slice-level value for feature k. After this operation, each slice is represented by a vector of 256 values and a series by an array of shape s × 256.

The second pooling operation condenses the slice dimension. For each feature, it selects the largest of the slice-level values.

zₖ = maxᵢ aᵢₖ

Here aᵢₖ is the spatially averaged response of feature k on slice i. maxᵢ searches over the slices in the current series. zₖ is the resulting value for feature k in the series representation. The operation produces a vector of 256 values regardless of the length of the input series.

This answers a basic problem of learning from whole-series labels. If evidence for a tear is concentrated in a few slices, the strongest response can reach the final classifier even when many slices contain little evidence. The operation selects a maximum independently for each feature. One feature can be taken from a slice near the middle of the series and another from a slice elsewhere. Accordingly, the pooled vector summarizes useful responses from the stack without first selecting a single representative slice.

The final layer for a series gives each element of the pooled vector a learned weight and adds a bias. A sigmoid maps the resulting score to the probability range.

p = σ(b + ∑ₖ wₖzₖ)

Here p is the probability assigned to the finding for the input series. σ is the sigmoid function, which maps an arbitrary real-valued score to the interval from 0 to 1. b is the learned bias, and wₖ is the learned coefficient for pooled feature zₖ. ∑ₖ adds the weighted responses across feature channels. A large positive combined score yields a probability closer to 1. A large negative score yields one closer to 0.

A separate instance of MRNet was trained for each pairing of series type and target, producing 9 series classifiers at Stanford. This lets the weights used to recognize an ACL tear on a coronal series differ from the weights used to recognize the same target on a sagittal series. It also lets the features for detecting any abnormality differ from those learned for a specific tear. The instances share the same broad architecture, which keeps the pipeline consistent when the labels and imaging series change.

Learning and choosing the series classifiers

The AlexNet part began with parameters previously learned on ImageNet, a collection the paper describes as having 1.2 million images across 1,000 categories. The authors then adjusted those parameters on the knee MRI training data. They chose this approach because learning a convolutional image classifier from random initialization generally requires more examples than their Stanford training set supplied. An existing feature extractor can already respond to patterns such as edges and lines. Training on the knee images can then adapt those responses and the later stages to the new task. This adaptation is fine-tuning.

For each target, MRNet learned by minimizing binary cross-entropy. The loss depends on the probability assigned to the recorded label. An exam labeled positive incurs a larger penalty when the classifier assigns a small probability to the finding. An exam labeled negative incurs a larger penalty when that probability is high. The authors weighted each example’s loss inversely to the prevalence of its class. A positive or negative class that supplied fewer training cases could thereby exert greater influence per example.

ℓ = −cᵧ [y ln(p) + (1 − y) ln(1 − p)]

Here ℓ is the loss for a training example. y is its binary label, 1 for presence of the finding and 0 for absence. p is the predicted probability of presence, and 1 − p is the probability assigned to absence. ln is the natural logarithm. cᵧ is the weight for the class represented by y, chosen inversely to that class’s prevalence. When y is 1, the first term supplies the penalty. When y is 0, the second term supplies it.

Training examples were randomly transformed as they were presented. The rotations ranged between –25 and 25 degrees, and translations ranged between –25 and 25 pixels. An example could also be flipped horizontally with 50% probability. These changes present different image orientations and positions while leaving the assigned diagnosis the same. They encourage the classifier to use evidence that survives such changes. The paper describes augmentation as part of the training procedure, so the resulting performance reflects the full pipeline in which it was used.

After each example, back-propagation computed how the loss depended on the parameters. The optimization then adjusted them in the direction that reduces the loss locally. After every pass over the training data, the authors saved the model parameters, then chose the version that yielded the lowest mean loss on the tuning set. Training a single Stanford MRNet for 50 passes took 6 hours on average on an NVIDIA GeForce GTX 1070 8GB GPU. That duration concerns parameter fitting. Once fitted, the network only has to compute its features and probabilities for a new input.

Combining the views of an exam

The series classifiers each produce a probability that pertains to one view and one finding. To obtain an exam-level probability, the authors fitted a logistic regression for each target. They fed it the series probabilities from the Stanford training exams, along with those exams’ original labels. The combining stage can learn whether a strong probability from one view tends to be more informative than the same probability from another. It applies that relationship to the series scores of a new exam.

P = σ(α + βₛpₛ + β𝚌p𝚌 + βₐpₐ)

Here P is the combined probability for one finding in the exam. pₛ, p𝚌, and pₐ are the probabilities from the sagittal, coronal, and axial classifiers for that finding. βₛ, β𝚌, and βₐ are their fitted coefficients, and α is the intercept. σ is again the sigmoid function. Each target has its own intercept and coefficients. These parameters express how the combining classifier uses the series scores together.

The architecture divides the task into image processing and combination. The image networks learn separately from the selected series. The regression combines their scores after each series has already been reduced to a probability. As a consequence, the regression can emphasize a view that frequently gives more reliable evidence for a target, but it receives no direct information about which location produced that evidence. The external dataset contained only a sagittal series, so the authors used a single sagittal MRNet score as the final output there.

Seeing what the network responds to

The authors used class activation maps to inspect the regions that influenced a score. A map starts with the spatial feature maps from a slice and weights them using the coefficients learned by the classification layer. This produces a coarse map with dimensions 7 × 7. The authors assigned colors to the result, scaled it to 256 × 256 pixels, and placed it over the original image. A bright area indicates a strong contribution under this weighting. It offers a way to compare what the network responded to with the location a specialist would inspect. That is a question of interpretability.

The map can be examined even though the network learned from exam labels. In the examples, a musculoskeletal radiologist marked the relevant anatomy and described the findings, so the reader can compare those annotations with the colored overlays. The annotations serve as a clinical reading of the illustrations. The network generated its probabilities from the images, and the maps were derived from its learned feature responses and final-layer weights.

The authors made the Stanford imaging data available through the MRNet project under a Dataset Research Use Agreement. The supporting materials include an implementation for the external validation and code for the statistical analysis.

Experiments and results

The data behind the comparisons

Across the Stanford collection, the clinical reports identified 1,104 (80.6%) exams as abnormal, 319 (23.3%) as having an ACL tear, and 508 (37.1%) as having a meniscal tear. The authors report 194 exams with both kinds of tears. The cohort had a mean age of 38.0 years. The scans came from a routine protocol in a single medical center, with 775 (56.6%) exams acquired at a magnetic field strength of 3.0 T and the remainder at 1.5 T. These details describe the conditions represented during development and in the internal evaluation.

A panel of 3 board-certified musculoskeletal radiologists established the reference diagnoses for the 120 internal validation exams. They could consult the full imaging record, the original report, clinical history, and follow-up exams. The reference for each finding followed the majority vote. Their reading identified 99 abnormal exams, 58 with an ACL tear, and 65 with a meniscal tear. For the same exams, the original clinical reports identified 96 abnormalities, 57 ACL tears, and 59 meniscal tears. The counts establish which labels underlie the performance results and show that the two labeling procedures did sometimes produce different conclusions.

The reference label for general abnormality included findings such as osteoarthritis, fracture, effusion, and contusion as well as the target tears. The ACL definition put low-grade and high-grade partial tears together with complete tears. Sprain, mucoid degeneration, and ganglion cyst were grouped with an intact ACL for the purposes of that particular classifier. A meniscal tear could be identified by a change in shape or by increased signal reaching an articular surface on at least 2 slices. Meniscal degeneration and postsurgical changes without a tear counted as negative for a tear. The binary labels therefore represent defined diagnostic questions. A negative tear label is compatible with other signs of disease on the scan.

For the stand-alone human comparison, the baseline was the pooled performance of 7 unassisted board-certified general radiologists. For the assistance experiment, those readers were joined by 2 orthopedic surgeons. The clinical experts were blinded to the original reports and labels. They reviewed the images in a diagnostic reading room using a clinical viewing system. The experts and the reference specialists had access to different accompanying information. The study uses the specialists’ label as the shared target for both the unassisted readers and the automated classifier.

Ranking exams and making decisions

AUC summarizes the receiver operating characteristic curve. The curve is obtained by varying the threshold that turns a probability into a positive call and examining how many reference-positive and reference-negative exams fall on the positive side. A higher AUC means better separation across that range of thresholds. It is possible for a classifier to rank exams well and still have an unfavorable balance of misses and false positives at a particular threshold. That distinction matters when comparing a score with a reader’s definite diagnosis.

For the internal decision-level evaluation, the paper used a threshold of 0.5. Sensitivity measures how frequently an exam positive by the reference standard is called positive. Specificity measures how frequently an exam negative by that standard is called negative. Accuracy measures the fraction of all decisions that agree with the reference. The paper gives 95% Wilson confidence intervals for these decision metrics and 95% DeLong intervals for AUC. The confidence intervals describe uncertainty around the estimates, which becomes particularly relevant when a metric depends on a small group of cases.

The stand-alone reader baseline is a micro-average. The authors pooled classification decisions from the general radiologists before calculating the group’s metrics. In the assistance experiment they computed changes for individual readers and tested whether the group’s performance improved. Those analyses answer different questions. The first compares decisions from the system at a fixed threshold with the decisions of unassisted readers. The second asks how an individual’s decisions change when the score is available.

The paper adjusted for multiple comparisons by controlling the false discovery rate. It reports an unadjusted p-value alongside an adjusted q-value. The latter is used for the paper’s significance criterion of less than 0.05. Because the experiment tests several metrics for each target, some differences can look persuasive when examined individually without meeting the study’s criterion across the set of comparisons. The distinction has a direct bearing on which assisted-reading improvements the authors could claim.

Stand-alone performance at Stanford

The strongest internal discrimination was for ACL tears, with an AUC of 0.965 and a 95% confidence interval of 0.938 to 0.993. General abnormality detection had an AUC of 0.937, with an interval of 0.895 to 0.980. Meniscal tear detection had an AUC of 0.847, with an interval of 0.780 to 0.914. These are the exam-level results after combining the selected MRI series. They describe the relative strengths of the three predictions within the Stanford validation set.

MRNet AUC by finding on the Stanford internal validation set

The system separated positive from negative exams most clearly for ACL tears.

MRNet AUC by finding on the Stanford internal validation setGeneral abnormality: 0.937General abnormality0.937ACL tear (this paper): 0.965ACL tear (this paper)0.965Meniscal tear: 0.847Meniscal tear0.847
The numbers
System or settingAUC
General abnormality0.937
ACL tear (this paper)0.965
Meniscal tear0.847

At the fixed threshold, general abnormality detection produced a sensitivity of 0.879, specificity of 0.714, and accuracy of 0.850 for MRNet. The corresponding micro-averages for the general radiologists were 0.905, 0.844, and 0.894. The specificity interval for MRNet extended from 0.500 to 0.862, reflecting the limited number of reference-negative exams. The paper found no statistically significant difference between the system and the general radiologists on any of the abnormality measures. The point estimates favor the readers on this split, and the statistical comparison leaves room for uncertainty about the size of the differences.

For ACL tears, the fixed threshold had high specificity and lower sensitivity. The specificity was 0.968 for the system and 0.933 for the general radiologists. That difference did not meet the statistical criterion. The sensitivity was 0.759 for the system and 0.906 for the general radiologists. This difference favored the readers after correction, with p = 0.002 and q = 0.019. The corresponding accuracies were 0.867 and 0.920. Reading those figures alongside the AUC shows how much the comparison depends on the decision being evaluated. The score ranked ACL findings well, while a substantial portion of reference-positive cases fell below the study’s threshold.

ACL tear sensitivity on the Stanford internal validation set

Unassisted general radiologists detected more reference-positive ACL tears than MRNet at its fixed threshold.

ACL tear sensitivity on the Stanford internal validation setMRNet at threshold 0.5 (this paper): 0.759MRNet at threshold 0.5 (this paper)0.759Unassisted general radiologists, micro-average: 0.906Unassisted general radiologists,micro-average0.906
The numbers
System or settingSensitivity
MRNet at threshold 0.5 (this paper)0.759
Unassisted general radiologists, micro-average0.906

For meniscal tears, MRNet achieved specificity of 0.741, sensitivity of 0.710, and accuracy of 0.725. The corresponding reader sensitivities and accuracies in the comparison table were 0.820 and 0.849. The paper consistently reports a statistically significant specificity advantage for the general radiologists, with p = 0.003 and q = 0.019, but gives different point estimates for their specificity. The comparison table gives 0.882, while the results narrative gives 0.892. The two entries support the same direction of the result. They leave the exact reported reader estimate ambiguous.

The study compared the fixed-threshold predictions with the general radiologists using a two-sided Pearson chi-squared test. The surgeons’ decisions were excluded from this stand-alone baseline. As a consequence, the comparison establishes where the findings differed from those of unassisted general radiologists under the study conditions. The surgeon readings contribute to the separate question of whether access to predictions helped the mixed panel.

What changed when clinicians saw the probabilities

The authors used a crossover design, in which readers experienced both conditions. The general radiologists were randomly assigned to groups that began in opposite conditions, and the orthopedic surgeons started without assistance. After a washout period of 10 days, the readers switched conditions and reviewed the exams in a different order. During the assisted session they saw probabilities for positive findings. The choices remained theirs. The study could therefore look for a change in how readers handled evidence when a score was available.

The authors tested the change in each performance measure with a one-tailed t test, using the paired differences across the 9 clinical experts. ACL specificity improved by a mean of 0.048, with a 95% confidence interval of 0.029 to 0.068. The result had p < 0.001 and q = 0.006. In clinical terms, the experts more reliably recognized exams that the specialist panel judged negative for an ACL tear. The result is compatible with the stand-alone system’s tendency to be specific at the chosen threshold, although the experiment measures the change in reader decisions and does not identify which individual cues produced it.

The table also shows a mean increase of 0.023 in ACL accuracy and of 0.052 in meniscal tear sensitivity. The unadjusted p-values were 0.020 and 0.028, respectively. After adjustment, the q-values were 0.092 and 0.110. Neither satisfied the study’s significance criterion. The mean change in ACL sensitivity was −0.004, and the mean change in meniscal tear specificity was −0.006. The estimates make clear that access to scores did not move every metric in the same direction. ACL specificity is the result supported by the paper’s adjusted tests.

The authors used the 62 reference-negative ACL exams to illustrate what the observed increase in specificity might mean in a clinical setting. Under their hypothetical scenario, it could translate into potentially 3 fewer patients being sent unnecessarily to surgery for a suspected tear. The measured outcomes in the reader experiment were image classifications. The hypothetical consequence depends on how an erroneous positive reading would have affected management, which the retrospective study did not record.

The timings likewise have a specific scope. The authors report that all automated classifications for the internal validation exams were available in under 2 minutes, against more than 3 hours on average for the clinicians to review the 120 exams. This comparison gives the scale of time needed to produce the scores. It leaves open how long a clinician takes to read an exam with the scores available and whether presenting the scores saves time within a clinical workflow.

Transfer to Rijeka

The external dataset from Clinical Hospital Centre Rijeka contained 917 exams acquired with a Siemens Avanto 1.5-T scanner. Štajduhar and colleagues derived the original injury labels from radiology reports. These included 690 exams without ACL injury, 172 with partial injury, and 55 with complete rupture. MRNet’s external task grouped partial injury and complete rupture into the same positive class. The authors used stratified sampling to create training, tuning, and validation sets in a 60:20:20 ratio and evaluated the external results on 183 held-out exams.

The experiment applied the Stanford sagittal T2 ACL classifier directly to the external series. The paper identifies the Rijeka sequence as PD-weighted in its methods and as T1-weighted elsewhere. The consistent facts for interpreting the result are that the external data came from a different institution, contained a single sagittal series, and used a different convention for labeling ACL injury. The experiment tested the transfer of the sagittal predictor under all those changes together.

Without training on Rijeka images, the Stanford predictor achieved an AUC of 0.824, with a 95% confidence interval of 0.757 to 0.892. The authors also trained MRNet on the external training subset, starting from ImageNet weights. They fitted 3 versions using different random seeds and used the external tuning set to select the version with lowest average loss. That classifier achieved an AUC of 0.911, with an interval of 0.864 to 0.958, on the same held-out Rijeka set.

ACL injury AUC on the Rijeka external validation set

MRNet trained on Rijeka data discriminated better than the classifier transferred directly from Stanford.

ACL injury AUC on the Rijeka external validation setStanford sagittal MRNet without additional training: 0.824Stanford sagittal MRNet withoutadditional training0.824MRNet trained on Rijeka data (this paper): 0.911MRNet trained on Rijeka data (thispaper)0.911
The numbers
System or settingAUC
Stanford sagittal MRNet without additional training0.824
MRNet trained on Rijeka data (this paper)0.911

The best semi-automated approach reported by Štajduhar and colleagues, which used support vector machines, achieved an AUC of 0.894. Their estimate came from 10-fold cross-validation, whereas MRNet was assessed on its held-out split. The figure gives historical context for performance on the external dataset. The comparison between the two MRNet training conditions is more directly interpretable because both were evaluated on the same exams. The external experiment measured discrimination, so it leaves the clinical performance of a particular probability threshold at Rijeka undetermined.

What the ablations show

The paper contains no systematic architecture ablation, but it offers a controlled training-data comparison, an analysis of the weights given to the imaging series, selected visualizations, and checks on the reader-study result.

Which series contribute to the combined score

According to the fitted logistic regressions, axial PD was the most beneficial series for general abnormality and meniscal tear detection, and coronal T1 was the most beneficial for ACL tears. The authors judged relative contribution from the coefficients assigned to the series scores. This is evidence that the fitted combination treats the views differently across tasks. The series that contributes most to one finding need not contribute most to another, which helps explain why the authors fitted the combining stage separately for each target.

A coefficient describes the role of a score in a calculation that already has access to the other views. It can be affected by how scores from different series are distributed and by how much their evidence overlaps. The analysis gives no held-out estimate for a Stanford system with its highest-weighted series removed. It also gives no estimate of how well that series would work by itself across all targets. Those comparisons would require separate evaluations of the corresponding input combinations.

The held-out external comparison is a stronger test of the contribution of training data to that particular task. Both MRNet settings used the same kind of sagittal classifier and were scored on the same external validation exams. One used weights learned from Stanford knee MRIs, while the other learned from the external training set after ImageNet initialization. The better externally trained result supports the value of fitting to locally representative data. The comparison changes the training images and labels together, so it cannot determine how much of the gain came from scanner characteristics, sequence differences, the case distribution, or the injury labeling convention.

What the activation maps reveal

The activation overlays let a specialist examine whether a correctly classified image also contains a strong response at a plausible site. In one abnormality example, the scan showed a large effusion and a ruptured gastrocnemius tendon. The overlay highlighted the regions the specialist identified as abnormal. The authors say the training data contained no other examples of that particular tendon injury. The example illustrates that a classifier trained with a broad abnormality label can respond to unfamiliar pathology. It is an individual observation, with no estimate of how reliably other rare abnormalities would be detected.

Another illustrated exam showed a complete ACL tear in spite of significant motion artifact. MRNet assigned the correct class, and the overlay emphasized the tear region. The authors retained scans with technical noise in their training and validation data to better represent clinical images. The case demonstrates a successful classification in the presence of motion. It provides no subgroup measurement of sensitivity or specificity for scans affected by motion, metal, or other artifacts. A further example of a complete ACL tear showed an important response where the injured ligament attached.

The meniscus illustration shows why the location matters independently of the class. The system assigned a positive general abnormality score to an exam with a complex tear in the posterior horn of the lateral meniscus. The highlighted region corresponded to increased signal in the anterior and lateral soft tissues. In the authors’ reading of the map, that signal contributed to the positive abnormality call. A correct broad label can thus be supported by a region apart from the particular injury a clinician is interested in, and the broad prediction alone cannot tell the reader which finding drove it.

Whether the assistance result depends on the surgeons

The authors repeated the analysis of assisted reading using general radiologists alone. ACL tear specificity still improved significantly, with p = 0.003 and q = 0.019. This sensitivity analysis addresses a concrete question about the combined panel. The improvement persisted when the orthopedic surgeons’ changes were excluded. The surgeon group was too small for a formal analysis of its own, so the experiment offers much firmer evidence about the radiologists than about a distinct effect for surgeons.

The authors also measured agreement with exact Fleiss kappa, which summarizes agreement among several readers after accounting for agreement expected by chance. Among the reference specialists, kappa was 0.508 for abnormality, 0.800 for ACL tear, and 0.745 for meniscal tear. The ordering is consistent with the broad abnormality judgment allowing more variation in what experts considered significant. It also shows that the majority reference was formed from readings with different levels of agreement across the targets.

Among the 9 clinical experts, kappa rose with assistance from 0.571 to 0.640 for general abnormality, from 0.754 to 0.840 for ACL tears, and from 0.526 to 0.621 for meniscal tears. These are descriptive changes. The authors did not test their statistical significance. Readers looking at a common score may arrive at more similar calls, whether the shared call is correct or incorrect. The specificity result measures agreement with the reference on negative ACL exams, while the kappa results measure agreement among the readers themselves.

Limitations

Limits the authors identify

The internal reference came from musculoskeletal radiologists rather than consistent surgical confirmation. Several sources of clinical information were available to the reference readers, and their majority vote supplies a specialist standard for interpreting the findings on MRI. What it establishes is how closely the predictions and reader decisions match that standard. When the reference panel disagrees with an automated call, the design cannot always distinguish an error by the system from a case in which an independent confirmation would have changed the reference diagnosis. The different levels of specialist agreement show why this issue has more force for some targets than for others.

The Stanford classifier was developed at one academic institution. The authors regard the gap between direct transfer and local training at Rijeka as evidence that optimal performance may require development on images more like those encountered in practice. The external data provide a genuine change of institution and protocol, but the authors could not assess whether transfer would have been stronger with a more closely matched set of MRI sequences or with several external views. They also leave open whether training on larger, multi-institutional collections would reduce the need for local development.

The reader panel was small. Its size limits the ability to detect modest gains in reader performance and makes separate conclusions about orthopedic surgeons particularly difficult. A failure to reach significance for a metric can reflect limited information about the effect as well as the size of the observed change. For meniscal tear sensitivity, for instance, the estimated change was positive, but uncertainty and the adjustment for multiple comparisons prevent a firm conclusion about improvement. That is a different evidentiary position from the adjusted result for ACL specificity.

The authors also treat broad abnormality detection as an open research question. Their example involving the gastrocnemius tendon suggests that a rare condition can be flagged even when the training data did not contain another example of it. They leave the scope of that behavior unresolved, especially for subtler abnormalities. The broad label combines diverse conditions, each with its own visual characteristics. Good performance across the label as a whole can coexist with weaker performance on particular findings that contribute few cases to the aggregate.

Finally, the authors call for prospective studies. Their findings come from stored examinations and a controlled reading exercise. The they report on assisted interpretation concerns a reader seeing image-based probabilities during that exercise. Clinical utility would also depend on where the result appears, who uses it, what they do after seeing it, and whether the resulting decisions improve care. Those links are central to the worklist and preliminary-reading uses discussed in the paper and were beyond the outcome measures of the study.

Additional limits apparent from the design

The internal tuning and validation sets were deliberately enriched with positive cases for each target. This made it possible to evaluate performance on enough examples of findings like ACL tears. It also means that the mix of exams differs from the full Stanford collection. Overall accuracy depends on that mix. So does the chance that a positive alert corresponds to a true finding, or that a negative alert can be trusted in a given service. The study’s specificity gain comes from a defined set of reference-negative exams. A different clinical population can change the practical consequences of that gain.

The distinction between discrimination and calibration matters for the assisted condition. AUC measures how well predictions rank exams. Calibration concerns whether a stated probability corresponds to the frequency of the finding among exams given similar scores. MRNet showed readers probability values, but the paper’s principal results do not establish how to interpret a particular value as an absolute risk in a different population. Class weighting, local prevalence, and differences in the labeling process all matter when moving from a score that separates cases to a probability used for a clinical decision.

The fixed threshold also deserves separate attention. For Stanford ACL tears, its high specificity describes how reliably MRNet called reference-negative cases negative. Using a negative score to exclude injury would also require attention to missed positive cases and to the prevalence in the setting where the score is used. The general radiologists’ significantly higher ACL sensitivity at the tested threshold is directly relevant to that question. Other thresholds could change the balance. The ROC curve illustrates possible tradeoffs, while the paper’s fixed-threshold results show the balance actually tested against the readers.

External validation covers a narrower target and input than internal validation. The Rijeka result concerns distinguishing uninjured ACLs from partial or complete injuries using a sagittal series. It cannot establish that the three-view Stanford combination transfers, that external patients benefit from assisted reading, or that abnormality and meniscal tear predictions remain accurate at the other hospital. In addition, the better local result came from a classifier trained directly on the external training data. That experiment leaves open whether adapting an already trained Stanford knee classifier would work as well or require fewer local examples.

The crossover design helps separate the effect of assistance from the tendency for some readers to be more accurate than others. Giving the same person the same cases under both conditions also makes the comparison sensitive to changes in that person’s decisions. The repeated cases create a possibility that readers remember a finding, even with a delay and a different ordering of the scans. Randomizing the starting condition for the general radiologists helps distribute order effects. The surgeons began in the same condition, which adds uncertainty to a specialty-specific interpretation of their changes.

The assisted readers could use the probabilities as they saw fit, so the experiment measures the net effect of making scores available. It cannot determine when a reader followed the number, when the number prompted a closer search, or when the reader discounted it because of image evidence. The comparison also concerns probabilities as the interface to assistance. The paper’s activation maps were an analysis of what the network responded to. The reader experiment does not show how presenting those maps during interpretation would change behavior.

The pooling architecture itself sets limits on what one can infer from a correct score. Averaging a feature across spatial locations condenses its response, and choosing its maximum over slices loses information about how that response changes through the stack. The classifier may exploit a highly informative slice. It does not explicitly track the continuity of a sign through adjacent images, even though continuity can matter to a clinical reading. The detailed meniscus reference rule illustrates this difference. The paper offers no comparison with a system trained to model the order of the slices or to predict spatial annotations.

The reference and clinical readers also worked with different information. The specialists could consult prior reports, history, and follow-up exams. The comparison readers were blinded to the original labels and reports. The predictions came from selected, preprocessed imaging series. All outputs were scored against the same reference, which makes the comparison clear, but the results describe performance under those assigned inputs. They do not settle how systems and clinicians would compare if both were given a different clinical record.

There is a final distinction between reading performance and deployment. The classifier’s speed makes it possible to imagine scores arriving early enough to affect an imaging queue. Testing a queue would require observing whose examinations were expedited, which were delayed, and what happened after a preliminary flag. Neither processing time nor AUC measures those outcomes. Likewise, fewer false-positive ACL calls in a retrospective reading task does not by itself show that fewer people undergo unnecessary procedures. The paper supplies an estimate for the classification step in a longer clinical process.

What came after

No later citing work is documented for this account. The paper leaves distinct follow-up questions about transfer to other imaging protocols and about the consequences of showing predictions during ordinary clinical care. Its cross-hospital test addresses the first for a single sagittal ACL classifier, and its crossover experiment addresses the second at the level of retrospective reading decisions. Subsequent effects on clinical workflows and patient outcomes cannot be established from those experiments.

Cite

Cite as Nicholas Bien, Pranav Rajpurkar, Robyn L. Ball, Jeremy Irvin, Allison Park, Erik Jones, Michael D. Bereket, Bhavik Natvar Patel, Kristen W. Yeom, Katie S. Shpanskaya, Safwan S. Halabi, Evan James Zucker, Gary S. Fanton, Derek F. Amanatullah, Christopher F. Beaulieu, Geoffrey M. Riley, Russell J. Stewart, Francis G. Blankenberg, David B. Larson, Ricky H. Jones, Curtis P. Langlotz, Andrew Ng and Matthew P. Lungren. 2018. Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet. PLoS Medicine.

The paper itself, not this page. BibTeX from the library's record of the work. DOI 10.1371/journal.pmed.1002699

@inproceedings{bien2018deep,
  title = {{Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet}},
  author = {Nicholas Bien, Pranav Rajpurkar, Robyn L. Ball, Jeremy Irvin, Allison Park, Erik Jones, Michael D. Bereket, Bhavik Natvar Patel, Kristen W. Yeom, Katie S. Shpanskaya, Safwan S. Halabi, Evan James Zucker, Gary S. Fanton, Derek F. Amanatullah, Christopher F. Beaulieu, Geoffrey M. Riley, Russell J. Stewart, Francis G. Blankenberg, David B. Larson, Ricky H. Jones, Curtis P. Langlotz, Andrew Ng and Matthew P. Lungren},
  booktitle = {PLoS Medicine},
  year = {2018},
  doi = {10.1371/journal.pmed.1002699},
  url = {https://doi.org/10.1371/journal.pmed.1002699}
}

↑ back to top

This page in Markdown https://md.research.elamur.ai/free/en/papers/bien-2018-deep-learning-assisted-diagnosis-knee/