Medical Image Analysis using Convolutional Neural Networks: A Review
Paper · 2018 · Syed Muhammad Anwar, Muhammad Majid, Adnan Qayyum et al.
Summary
A medical image can show where an abnormality lies, how far it extends, or how closely it resembles an earlier case. Each question calls for a different kind of answer, and the visual clues can be hard to specify in advance. Anwar and colleagues review how convolutional neural networks, or CNNs, learn those clues from images. The paper explains how the networks work, surveys applications across several imaging modalities, and compares results reported by the studies it covers.
A CNN learns small filters that respond to patterns in an image. It applies the same filter at different locations and combines the resulting responses over successive layers. Early layers can register edges and other local structures. Later layers can use those responses to represent parts of an organ or larger arrangements. Training connects these representations to a task. For instance, errors in predicting tumor tissue can change the filters that process the image as well as the layers that make the prediction. The review contrasts this training procedure with older pipelines in which researchers specified the visual descriptors before fitting a classifier.
The authors find that CNNs perform well across image segmentation, abnormality detection, diagnosis, and retrieval. The comparisons illustrate both the gains and their scope. On the BRATS 2015 brain tumor benchmark, the highest reported Dice score for overlap with the complete tumor is 0.91, achieved by 3DNet 3. Cascaded neural networks lead on the enhancing region, with a Dice score of 0.90. In a comparison for interstitial lung disease pattern classification, the CNN also has the highest accuracy, reported as 0.8561. These results come from separate studies, each evaluating a particular task and dataset.
The authors identify a practical tension running through the applications. A larger network can exploit more context, including information across slices of a scan, but it takes more computation to train and use. Training also depends on expert labels that can be difficult to obtain. The paper discusses ways to work with those constraints, including generating transformed examples from available images and adapting a network trained on a larger collection. It also raises questions about image noise and how to interpret what a network has learned. The evidence concerns performance on the reported image-analysis tasks. Improved clinical detection and diagnosis are outcomes the authors envisage as the methods develop.
Deep dive: Medical Image Analysis using Convolutional Neural Networks: A Review
Anwar and colleagues review how convolutional neural networks learn from medical images for segmentation, disease detection, diagnosis, and retrieval. · about 34 minutes to read
The problem and its context
What an image analysis system has to return
Medical imaging supplies visual evidence for diagnosis and treatment. Images from X-rays, CT (computed tomography), MRI (magnetic resonance imaging), ultrasound, and other methods are covered in the review. It also discusses positron emission tomography and combinations of modalities. Different acquisitions provide information about anatomy and function. In the studies the authors survey, the form of the image matters to the analysis. Some inputs are individual images or slices, while others are volumes whose structure extends across slices.
The paper treats image analysis as a family of tasks. Consider a suspected tumor on an MRI scan. A detection system might flag an abnormality or indicate where to look. A segmentation system assigns parts of the image to regions so that a reader can examine the tumor’s boundaries and extent. A classification system assigns a category to an image or a selected region. The differences affect what the system learns and what researchers need to measure. A correct image label can answer a classification question while leaving the shape and position of the abnormality unspecified.
Segmentation divides an image into regions. In a simple case, it separates the structure of interest from the surrounding background. The resulting regions can be used to describe shape, volume, or position relative to other anatomy. The review also covers problems in which a structure has several components of interest. Brain tumor segmentation is one example. A system may have to outline the full tumor as well as particular regions within it. How well it traces the outside boundary and how well it identifies internal regions are distinct questions.
For abnormality detection, the motivation is the effort and time involved in examining images. The authors describe computer-aided systems as possible second readers. Such a system can call attention to suspicious image content or provide information about a region while a practitioner interprets the study. Computer-aided diagnosis places the emphasis on what that evidence means. The review uses examples from several clinical applications, including mammography, the analysis of cardiac MRI, and the interpretation of images of the eye. Each requires a definition of the abnormality and a suitable image source before the learning problem can be specified.
A further task arises after images are stored. Hospital picture archiving and communication systems accumulate large collections, and a clinician may want to consult earlier cases with similar appearances. A retrieval system ranks images in response to a query. The resemblance could concern the appearance of a lesion, the kind of anatomy pictured, or another property represented in the archive. The paper discusses automatic organization and search because manually describing every image takes time and depends on what each person chooses to record. This is an application of information retrieval.
How earlier methods represented images
The authors describe older systems in terms of the choices researchers made about which image properties to preserve. In a typical computer-aided diagnosis pipeline, a preprocessing stage prepares the image. Feature extraction then converts the pixels into measurements, and feature selection narrows the measurements used by the final classifier. A feature might describe local texture, an edge pattern, or some aspect of shape. Designing and selecting these features requires an account of which visual properties will help separate the categories of interest.
Earlier segmentation methods used several kinds of image evidence. The review describes multiscale thresholding for volumetric images, in which an algorithm examines the data at different levels to reduce the influence of noise and weak edges. An ultrasound method combines clustering with a technique for estimating boundaries. Another approach uses statistical shape information and hierarchical clustering. These examples place different assumptions at the center of the analysis. An intensity threshold relies on separation in pixel values, whereas a shape description makes the expected geometry part of the decision.
The methods for detecting abnormalities were similarly varied. One brain tumor approach combined information from MRI segmentations. A mammography approach used particle swarm optimization, texture measurements, and a support vector machine. The support vector machine is the classifier in that pipeline. Its inputs are the measurements prepared by the preceding stages. Another study examined abnormalities of the heart muscle with cardiac MRI. The diversity of these examples helps explain the review’s interest in feature learning. A descriptor that captures a useful pattern in breast tissue has to be justified separately from a descriptor for a brain tumor or a cardiac abnormality.
The paper gives examples of earlier diagnostic systems for conditions including fatty liver, prostate cancer, and glaucoma. It also describes a study that combined clinical and image features to classify Alzheimer’s disease. This last example shows that researchers could choose inputs beyond the image itself when those inputs served the diagnostic question. In another example, local descriptions of blood vessels were used to locate the optic disc. The sequence illustrates how a diagnosis pipeline can include a more specific image task whose result is useful to the later decision.
Earlier retrieval systems took either text descriptions or measurements derived from images as their starting point. Text search could work well when descriptions were available and informative. Collection coverage depended on the extent and quality of manual description. Content-based image retrieval instead characterized the visual material itself, using properties such as texture, color, and shape. Some systems used a predicted class to narrow the pool of candidates before checking similarity. In that arrangement, classification and retrieval address different stages of the search. The class prediction determines which images are considered, and the similarity comparison orders the candidates.
The review discusses a retrieval approach for Alzheimer’s disease that used the scale-invariant feature transform, or SIFT, with a bag of visual words. SIFT supplies local image descriptors. The bag-of-words representation summarizes which kinds of descriptors occur across an image. This describes the image in a form that can be compared with other images or given to a classifier. It also illustrates the separation that concerns the authors. A downstream error can reveal a problem with the overall choice of representation, but fitting the classifier leaves the procedure for generating the local descriptors as it was.
Why learning visual features mattered
The paper situates the interest in CNNs alongside improvements in imaging equipment, computing, and digital storage. More images were available to analyze, and research on visual recognition had demonstrated ways to learn features from large collections. That combination made it practical to ask what a system could extract from pixels when researchers supplied examples of the desired output. The authors place this development within machine learning.
The review describes deep learning as arranging successive layers of transformations so that each layer can build on the previous one. It lists autoencoders, restricted Boltzmann machines, and deep belief networks among the available approaches. CNNs are the focus because their structure makes direct use of the spatial relationships in an image. Nearby pixels can form a local pattern, and a pattern learned in one location may matter elsewhere. Putting these properties into the architecture changes which parameters the system has to learn from examples.
Among the architectural precedents is LeNet-5, which the authors discuss as a network for recognizing handwritten characters. They also cite very deep networks used for general image recognition as a point of comparison. Medical studies, in the authors’ account, frequently favored shallower architectures because of limited training data and scarce expert labels. Depth was already an available design choice. The medical question was how much depth a particular task and collection could support. The earlier computer-vision work they cite includes Very Deep Convolutional Networks.
The choice of training examples goes together with the choice of task. A set of organ labels can support learning to assign an organ category. A segmentation system needs supervision that connects the desired regions to positions in the image. A retrieval study must decide which images count as relevant to a query. The authors also describe a gap in expertise between clinicians and deep-learning specialists. Tutorials and publicly available implementations made it easier to get a system running. Clinical knowledge was still needed to specify useful outputs, assess labels, and decide which measures would reflect the intended application.
The method, step by step
From a patch of an image to a class prediction
The paper is a review, and its classification diagram illustrates a common CNN design. The example accepts a 32 × 32 patch taken from a 2D medical image and returns a prediction among N classes. Here N is the number of classes defined for the task. The patch could contain a characteristic region of tissue or a recognizable portion of an organ. The network first extracts local responses, then condenses and combines them, and finally uses the combined information to predict a class.
Patch classification in the review’s example CNN
The steps in order.
The first operation to understand is the local filter. At any given position, a filter receives a small group of neighboring values. That group is the unit’s receptive field. The filter combines the values using learned weights. A filter that responds strongly to an edge, for instance, gives a high response where the neighboring intensities line up with the pattern its weights encode. Each move across the input gives another response, and the responses arranged by location form a feature map.
In a convolutional layer, a filter uses the same weights wherever it is applied. Its bias, an additional learned value, is shared across those positions as well. This means a useful local pattern can be detected in different parts of the image using the same parameters. During training, the shared weights receive contributions from the positions at which the filter was used. The paper describes the gradient for a shared weight as a sum over those contributions. A gradient describes how a small change in a parameter affects the training objective.
A layer typically has several filters, each producing its own map. The next layer can examine patches from that stack of maps. The authors illustrate the idea with a 2 × 2 spatial window and explain that the filter weights for this example have dimensions for the input maps and for the positions within the window. At each spatial position, the filter combines local values across the input maps. This gives later layers a way to learn which lower-level responses tend to matter together.
The paper gives the following feature-map expression, using the hyperbolic tangent as its example activation function.
hᵏᵢⱼ = tanh((Wᵏ ∗ x)ᵢⱼ + bᵏ)
Here hᵏᵢⱼ is the output on feature map k at spatial position i, j. The index k identifies the filter that produces the map, and i and j identify the position within it. Wᵏ is the set of weights for that filter, x is the input image or the incoming feature maps, and ∗ denotes convolution. The subscript on the convolution result selects the response at i, j. The value bᵏ is the learned bias for filter k, and + adds it to that response. The function tanh transforms the resulting value into the activation recorded on the map.
An activation function determines how a unit’s output changes with its input. The paper distinguishes linear functions, which can pass values through directly, from nonlinear ones. Nonlinear activations allow successive layers to produce transformations more complex than a sequence of linear operations. Besides the hyperbolic tangent in the equation, the authors discuss the sigmoid and the rectified linear unit, or ReLU, along with variants of ReLU. The equation describes one way to calculate a feature map within the broader family of networks covered by the review.
The next operation in the example is pooling. Max pooling groups nearby positions and retains the strongest response in each group. The resulting map covers the same span of the input with fewer values. A small movement of a pattern within the group can leave the pooled response similar, which helps when exact location is secondary to the presence of a visual feature. Pooling also reduces how much information the following layer must process. The review describes these effects as ways to gain some robustness to changes in position.
The alternative pooling operations serve different purposes. Mean pooling replaces a region of responses with their average, and stochastic pooling selects a response at random within the region. The authors also discuss pooling across overlapping regions. A strong response can coexist with weaker nearby evidence that still matters to the task. The choice of pooling region therefore affects which details continue through the network. A class prediction may tolerate some loss of spatial precision, whereas a segmentation boundary depends on how well the output preserves or recovers location.
The fully connected layers at the end of the illustrated classifier use the feature responses to make a class prediction. The paper connects this progression to increasing receptive context. Early layers can respond to edges, blobs, or other local structures. Later layers can bring such evidence together over larger areas and potentially register parts of an organ or a whole organ. These are examples of how the authors interpret successive layers. The training procedure determines the actual responses.
How the prediction changes the filters
For supervised learning, the network receives images with target outputs. A loss function measures the error in its predictions. The training procedure propagates information about that error backward through the layers so that the parameters producing the visual features can change along with the parameters making the final prediction. If one arrangement of edge responses helps the network distinguish the desired tissue categories, the loss can favor filters and combinations that make that arrangement easier to recognize.
This connection to the loss is the review’s main explanation for the advantage of end-to-end training. In the earlier pipeline the authors describe, SIFT descriptors might be grouped into a bag-of-words representation and sent to a classifier. The classifier learns which aspects of that fixed representation predict the label. A CNN can adjust the filters that determine what evidence reaches the classifier. The target consequently helps shape the visual representation itself.
The authors discuss overfitting as a central training problem. A network can come to fit the available training examples closely while generalizing poorly to other images. Its parameter count depends on the layers, the number of units, and how they are connected. The small kernels used in one brain tumor segmentation study reduce the parameters needed for a convolution and allow the architecture to have more layers. This makes kernel size one of the ways the reviewed studies balance network depth against the amount of available data.
Another approach is dropout. The review explains it as randomly dropping selected connections during training, which changes the combination of responses available in a training pass. Batch normalization is discussed in connection with training on mini-batches, which are groups of training examples processed together. The authors describe it as a way to speed training that can also provide regularization. Regularization is used to improve generalization by limiting how closely the network adapts to particular details of the training set.
Data augmentation changes the examples the network sees. The review lists random cropping, color changes, flipping, and rotation as possible transformations. It also describes intensity normalization and augmentation in a particular MRI segmentation study. Normalization adjusts the image values before learning, while augmentation produces variations of available examples. In a supervised task, the intended meaning of the label needs to hold after the transformation. For a segmentation example, a geometric transformation also changes the positions to which the labels refer.
The paper discusses transfer learning as another response to scarce labels. In the version it describes, training on a large collection such as ImageNet supplies a starting set of network parameters. The network is then adapted using medical images for the target task. The authors’ illustrative learning rate goes from 1e − 2 to 1e − 3 or 1e − 4. These values describe the size of training updates in their example. They also describe a factor of 10 increase in the local learning rate for newly introduced layers. The idea is to adapt the existing parameters gradually while letting the new layers learn more quickly. The adaptation stage is called fine-tuning.
The authors also consider pretraining on grayscale versions of ImageNet data and on a large annotated medical collection. In the latter case, they suggest that the initial task could be organ classification or distinguishing benign from malignant images. The medical collection could draw on multiple modalities. This is a proposed source of reusable features. Its suitability would depend on what the starting task teaches the filters and how that relates to the destination task. The review gives these options as alternatives available to researchers facing different amounts of labeled data and computing capacity.
How the reviewed systems adapt the architecture
The patch classifier shows a network making a decision for a compact input. For segmentation, the desired result has a spatial layout. One brain tumor study reviewed in the paper replaces fully connected processing with convolutional processing to speed segmentation. Its cascade sends the first network’s output forward together with the input to the next network. A later stage can therefore use features drawn from the image as well as an earlier prediction about its contents.
Other brain studies build context into the input or the network itself. A slice-based method considers an entire MRI slice and uses reweighting during training to address class imbalance. In this setting, imbalance means that the training data give some categories more representation than others. Reweighting changes the contribution categories make to training. The whole slice provides spatial context around each location, while the weights affect which errors the network has a greater incentive to correct.
A brain lesion method uses 3D patches, dense training, and separate processing paths. After the network produces its predictions, a fully connected conditional random field is used to reduce false positives and refine the output. A conditional random field can use relationships among predicted locations when making the final assignment. It is a postprocessing stage in this account. Another reviewed volumetric system also uses separate paths to classify locations in MR images. These systems share an interest in context while putting it to work in different parts of the procedure.
The authors describe encoder and decoder arrangements for segmentation as well. In the U-shaped volumetric network they discuss, convolutional processing and decoding are paired with skip connections, which carry information from earlier stages into later ones. The structure lets the reconstruction stages use features computed before spatial detail was reduced. The reviewed work used sparse annotations for a volumetric segmentation task. Other examples include a modification to the U-shaped design for several datasets, a W-shaped arrangement for 2D segmentation, and a capsule-based design for lung images whose authors report substantially fewer parameters than U-Net.
A scan volume can also be processed as slices or represented using several views. This allows a network to work with planes taken from the same volume and combine the information they reveal. Volumetric convolution instead takes a neighborhood that extends through the scan. The review’s examples range from neonatal MRI classification to the detection of vascular lacunes and the segmentation of cerebral vessels. The authors connect the choice of volumetric processing to larger networks and slower inference, the stage at which a trained network produces predictions. Slice, multi-view, and volumetric approaches are different ways to balance spatial context with the cost of processing it.
Classification studies make their own choices about what enters the network. For lung pattern classification, the review describes extracting patches from CT images of size 512 × 512. It reports that 14,696 patches from the original scans were used for training the CNN. A separate study on lung CT uses a convolutional restricted Boltzmann machine for work on lung tissue and airway centerlines. Its training patches measure 32 × 32, overlap by 16 voxels along the grid, and are retained when 75% of the voxels belong to the same class. A voxel is a location in a volume. In this study, the retention rule makes class composition part of how the input examples are chosen.
For body part recognition, the review describes a procedure that first identifies patches that are informative about the body part and distinguishes them from patches with little discriminating information. The second stage adapts the network parameters using the informative patches. The distinction is useful because a CT slice can contain areas with very different value for recognition. In the colon histology study, the task is to detect cell nuclei and classify them. The network uses information from the local area, and a neighboring ensemble contributes to the classification. The authors describe an evaluation collection with 20, 000 annotated nuclei across four classes.
Retrieval changes the role of the final layers. In the review’s multimodal example, a network is trained to recognize image classes, and features from its fully connected layers are used for retrieval. During classification, those layers combine information in service of predicting a category. During retrieval, their responses provide a way to describe images for similarity comparisons. The other radiographic retrieval example is evaluated using the Image Retrieval in Medical Applications database, abbreviated IRMA. The review gives these as examples of how features learned from images can support archive search.
How the paper defines performance
The authors provide equations for measures used across the surveyed tasks. The counts in these equations describe outcomes relative to a reference label. A true positive is a correctly flagged case. A false positive is a case flagged despite belonging to the negative category. A true negative is a correctly rejected case, and a false negative is a positive case that was missed. In a particular study, the unit being counted can be an image, a selected region, or another labeled observation. That unit matters when interpreting the reported value.
Precision = TP / (TP + FP)
TP is the true positive count. FP is the false positive count. Adding the two gives the number of predicted positives, and division gives the fraction of those predictions that are correct. Precision describes how often a positive call is right among the calls the system actually makes.
Recall = TP / (TP + TN)
Here TP denotes true positives, and TN denotes true negatives. The denominator adds those counts, as printed in the review’s recall equation, and the numerator is divided by that total. This denominator counts correct outcomes and so fails to count all actual positives. The paper’s separate sensitivity equation gives the usual fraction of actual positives recovered. The recall values in its comparison table are reported results from the studies, and the review does not explain how they relate to its printed equation.
F1 = 2 × (Precision × Recall) / (Precision + Recall)
F1 is the combined score, and Precision and Recall are the two input measures. The factor 2 multiplies their product, marked by the inner multiplication sign ×. The division uses the sum of the input measures as the denominator. With the usual meaning of recall, a high F1 requires the system to be good at both making reliable positive predictions and recovering the positives in the data.
Accuracy = (TP + TN) / (TP + TN + FP + FN)
TP and TN count correct positive and negative decisions, respectively. FP counts incorrect positive decisions, and FN counts missed positives. The plus signs combine the counts on each side of the division. The numerator contains the correct decisions, while the denominator contains all the decisions. Accuracy therefore measures overall agreement with the labels.
Sensitivity = TP / (TP + FN)
TP is the count of correctly identified positives, and FN is the count of missed positives. The denominator adds them to obtain the number of actual positives. The quotient is the share of actual positives that the system identified. This is the measure that directly answers how often labeled abnormalities were caught in a binary detection task.
Specificity = TN / (TN + FP)
TN is the count of correctly identified negatives, and FP is the count of negatives called positive. Their sum in the denominator counts the actual negatives. The division yields the share of actual negatives that the system correctly leaves unflagged. In a study where missed findings and false alarms matter separately, sensitivity and specificity preserve information that an overall accuracy figure combines.
DiceScore = 2 × |P ∩ GT| / (|P| + |GT|)
DiceScore is the overlap score. P is the set of locations predicted for the region, and GT is the corresponding ground-truth region, meaning the region given by the reference labels. The intersection sign ∩ selects the locations shared by the two sets. The vertical bars count the locations in each set or intersection. The factor 2 multiplies the size of the shared part, and division uses the sum of the predicted and reference region sizes. Where a benchmark distinguishes several tumor regions, each region can have its own Dice score.
Experiments and results
Brain tumor segmentation on BRATS
The review’s numerical evidence comes from the studies it surveys. Its clearest segmentation comparisons group results by BRATS challenge dataset and by the part of the tumor being outlined. The complete, core, and enhancing regions each have separate Dice scores. These categories matter because a good outline of the complete tumor can coexist with a weaker delineation of a specific component.
For BRATS 2013, the review reports results for InputCascade CNN, Pereira’s CNN, and the method shown as Lisa in the segmentation table. InputCascade CNN has the highest values in that group. Its Dice scores are 0.88 for the complete tumor, 0.79 for the core, and 0.73 for the enhancing region. Pereira’s method records 0.84 for complete, 0.72 for core, and 0.62 for enhancing. The method listed as Lisa records 0.79 for complete, 0.68 for core, and 0.57 for enhancing. The order is consistent across the regions within that dataset grouping.
For BRATS 2015, the order changes with the region. The review gives results for Deep medic, SegNet, 3DNet 3, and Cascaded neural networks. 3DNet 3 has the highest complete-tumor Dice score, while Cascaded neural networks has the highest core and enhancing scores. The complete-tumor comparison shows how the methods rank when the evaluation is restricted to the full extent of the tumor.
Complete-tumor segmentation on BRATS 2015 by Dice score
The volumetric 3DNet entry leads on overlap for the full tumor region.
The numbers
| System or setting | Dice score |
|---|---|
| Deep medic | 0.89 |
| SegNet | 0.85 |
| 3DNet 3 (this paper) | 0.91 |
| Cascaded neural networks | 0.86 |
For the tumor core on BRATS 2015, the Cascaded neural networks entry has a Dice score of 0.87, followed by 0.83 for 3DNet 3, 0.75 for Deep medic, and 0.68 for SegNet. For the enhancing region on that dataset, the corresponding scores are 0.90 for Cascaded neural networks, 0.76 for 3DNet 3, 0.72 for Deep medic, and 0.68 for SegNet. In particular, the complete-tumor leader has its strongest comparative result on the complete region, while the cascaded entry has its strongest comparative results on the component regions. The comparison therefore depends on what a segmentation is meant to delineate.
The architecture descriptions explain the range of approaches represented. The studies use combinations of patch-based processing, volumetric inputs, cascades, and postprocessing. The review groups their scores under the challenge datasets and tumor regions. It gives no finer split information alongside these entries. The rankings describe the values gathered in the review and provide a reason to read a segmentation result together with the target region.
Interstitial lung disease pattern classification
For interstitial lung disease, the comparison based on the named lung studies includes feature-based systems and a CNN. One baseline uses intensity textons, which express recurring local texture patterns, with a radial-basis support vector machine. Another uses a histogram of local binary patterns with a nearest-neighbor classifier. A further baseline uses a histogram of local discrete cosine transform features with a random forest. Each represents the image through a specified description before classification. The CNN learns the visual representation as part of training.
Accuracy of lung pattern classifiers on interstitial lung disease CT
The CNN has the highest reported accuracy among the lung pattern methods compared.
The numbers
| System or setting | Accuracy |
|---|---|
| Intensity textons with radial-basis SVM | 0.7152 |
| Local binary pattern histogram with nearest neighbors | 0.7333 |
| Local cosine transform histogram with random forest | 0.7809 |
| CNN (this paper) | 0.8561 |
The same comparison reports an average F measure, labeled F avg. The values are 0.7127 for intensity textons, 0.7322 for local binary patterns, 0.7786 for the local cosine transform method, and 0.8547 for the CNN. The order is the same on this measure and on accuracy. The review gives the score as F avg in the comparison and leaves its averaging convention unspecified there. Its application overview separately gives 85.5% accuracy for lung pattern classification on an interstitial lung disease CT collection of 109 high resolution scans and 7 classes. The review presents that overview figure separately from the decimal accuracy in the classifier comparison.
A related application entry describes lung texture classification and airway detection with a convolutional restricted Boltzmann machine. The review reports 89% accuracy, with 73 CT scans and 5 classes in the entry. The paired application name covers more than one objective, so the figure should be read as the accuracy the overview assigns to that entry. It supplies neither a separately identified airway detection score nor a basis for comparing this figure directly with the 7-class lung pattern result.
There is an editorial problem in the review’s pair of classifier comparisons. The comparison containing the lung studies and their texture features is headed as body organ recognition. The comparison containing Yan and colleagues’ body part recognition methods is headed as interstitial lung disease classification. The discussion also directs the reader to the tables in that order. The method names, the descriptions of their tasks elsewhere in the review, and the cited study titles identify the lung entries as lung pattern classification and the Yan entries as body part recognition. The comparisons here follow those study identities.
Recognizing body parts in CT slices
The body part recognition comparison attributed to Yan and colleagues evaluates combinations of image features and classifiers. Bag-of-words representations built from SIFT descriptors are paired with either linear regression, as labeled in the paper, or a support vector machine. The other feature baseline is the histogram of oriented gradients, or HOG, which summarizes the directions of local changes in intensity. HOG is paired with the same classifier choices. The CNN entry learns the image features and the prediction together.
F1 scores for body part recognition on CT slices
The CNN leads the tested combinations of fixed features and classifiers.
The numbers
| System or setting | F1 score as reported |
|---|---|
| Bag of words and SIFT with linear regression | 62.78 |
| Bag of words and SIFT with SVM | 64.17 |
| HOG with linear regression | 68.22 |
| HOG with SVM | 76.57 |
| CNN (this paper) | 92.23 |
The scores for precision and recall support the same ranking. The CNN records precision of 92.25 and recall of 92.21 in the body part comparison. Among the feature-based entries, HOG with an SVM has the highest values on both, with precision of 76.39 and recall of 76.75. HOG with linear regression has precision of 67.74 and recall of 68.71. The SIFT bag-of-words approach with an SVM records 63.72 and 64.63, respectively, and the corresponding linear regression approach records 62.21 and 63.37. These figures are reported on the scale used by the comparison.
The review’s application overview gives 92.23% accuracy for the body part recognition study. It lists 6000 synthetic examples, 7489 transversal CT slices, and 12 body organ classes. The method description mentions evaluation on synthetic data and on CT slices. The overview gives a single accuracy entry without identifying the split that produced it. The classifier comparison also contains the digits 92.23, there as an F1 score. The metric labels distinguish the two entries, and the review gives insufficient detail to determine the relationship between them.
Diagnosis, histology, and retrieval
The applications overview illustrates the range of settings in which the reviewed CNNs were used. In the study of nuclei in colorectal adenocarcinoma, the entry lists 100 histology images, 4 classes, and 80.2% accuracy. The methods discussion describes a larger count of annotated nuclei within the material used for evaluation. Those descriptions count different units. Histology images are the pieces of visual material supplied to the study, and the nuclei are the structures marked within them. The accuracy entry should be read in the context of the study’s detection and classification task.
For thyroid nodules, the review describes pretrained CNNs and a softmax classifier that produces a prediction across the diagnostic categories. The table lists 15,000 ultrasound images, 2 classes, and 83% accuracy. For breast cancer diagnosis, it describes semisupervised training, which allows unlabeled data to contribute alongside a smaller labeled collection. The overview reports 82.43% accuracy for a mammography study with 3158 regions of interest and 2 classes. A region of interest is a selected part of an image. The unit listed for that study is therefore a region, while the thyroid entry counts ultrasound images.
The diabetic retinopathy entry reports 75% accuracy for a Kaggle dataset of 80,000 images and 5 classes. The accompanying prose describes colored fundus images, which show the back of the eye, and discusses aneurysms, exudates, and hemorrhages. Those are the kinds of image evidence named in the prose. The review does not reconcile that description with the 5 classes in the results entry. The table and the bibliography identify which study the entry concerns.
For Alzheimer’s disease classification, the review reports 98.88% accuracy using the Alzheimer’s Disease Neuroimaging Initiative database, abbreviated ADNI. The overview lists 38,024 images and 4 classes. The authors describe the reported result as higher than those of traditional approaches to Alzheimer’s disease detection. They discuss deep architectures including GoogLeNet and ResNet, and the table associates the accuracy figure with a CNN study using ADNI. The overview gives an image count and class count without assigning the result to a particular test split.
The multimodal image classification and retrieval entry reports 99.77% accuracy for a collection with 7200 images and 24 classes. The method description explains that classification is used during training and that the resulting features support retrieval. The IRMA radiographic retrieval entry gives 97.79% in the accuracy column, with 14,410 images and 31 classes. The review uses the overview to show the range of applications. It provides limited information there about how each study defined successful retrieval. The figures can be attributed to their respective datasets and entries, while detailed conclusions about ranking relevance would require the underlying evaluation procedures.
These results cover different sources of evidence. In a brain segmentation study, the question is whether predicted locations agree with a marked region. In lung pattern classification, the question is which category best describes the tissue represented by an input. Retrieval can depend on how class information is used to determine relevance. A percentage in one application and a similar-looking percentage in another thus refer to different decisions, evaluated against different targets. The comparative evidence is clearest within the groups where the review names the candidate methods, the task, and a common measure.
What the ablations show
The review reports no ablation experiment of its own and instead analyzes published architectures, training choices, and comparisons between complete systems.
Where the feature comparisons isolate a choice
The body part recognition comparison has a useful structure because the fixed-feature baselines recur across classifier choices. With linear regression held as the classifier, HOG has higher reported precision, recall, and F1 than the SIFT bag-of-words representation. The same order appears when both feature representations are paired with an SVM. Within the family of inspected baselines, the choice of representation is associated with a consistent difference. The comparison makes that pattern visible by showing more than one classifier for each representation.
The classifier comparison can be read in the other direction as well. When the visual representation remains the same, the SVM entries have higher scores than the corresponding linear regression entries. The strength of the fixed-feature baselines therefore depends on both stages of the pipeline. HOG with an SVM is the strongest of those baselines in the table. The CNN’s lead is measured against that combination as well as against the other fixed-feature systems.
The CNN entry changes the representation and the prediction procedure together. Its scores support the authors’ claim that joint learning can produce a strong system for this task. They also fit the explanation advanced in the architecture discussion, in which the task loss can alter the filters extracting the features. The comparisons give no estimate of how much of the gain arises from adapting those filters, how much from the classification layers, or how much from the procedure for selecting discriminative patches. All of those choices are part of the system being evaluated.
For lung pattern recognition, the feature-based baselines pair different descriptors with different classifiers. The comparison asks which complete method achieves the best reported result. Its outcome favors the CNN across the average F measure and accuracy. Because the pairs change together, any conclusion about one feature or classifier in isolation requires evidence beyond these rows. The result is a comparison between practical approaches to the task.
What the segmentation comparisons can distinguish
The brain tumor results allow an analysis of the target definition. For BRATS 2013, the ranking holds across the regions. For BRATS 2015, the leader for the full tumor is different from the leader for the core and enhancing regions. The second pattern shows why an evaluation confined to complete-tumor Dice would hide strengths that matter when a reader needs internal delineation. A region-specific score is especially informative in the review because the compared architectures organize context and spatial output in different ways.
Those architectures combine several choices. The authors describe small kernels with preprocessing and augmentation in one system. Another work uses separate processing paths and a conditional random field after prediction. A slice-based approach combines wider image context with reweighted training. The descriptions make it possible to see which problems the designers intended to address, such as sparse training data, limited context, and false positives. The scores describe the resulting packages. They cannot assign the effect to a single component within each package.
The discussion of volumetric and slice-based processing is likewise an architectural analysis. The authors explain the context available to each approach and identify parameter count and processing speed as constraints. They describe a study in which a volumetric detector of vascular lacunes performed close to trained raters. They also describe several methods for constructing spatial predictions, including a capsule-based approach reported to use substantially fewer parameters than U-Net. These examples concern different tasks and different outcomes. They help explain the design space while leaving the size of each tradeoff dependent on the study.
What the training examples explain
The review attributes a purpose to each of several recurring training choices. Augmentation is used where the image collection is limited. Dropout is used to address overfitting. Small kernels help limit parameter count. Pretraining gives the network a starting representation before it sees the target examples. The examples explain how designers have tried to match an architecture and training procedure to the data they can obtain.
The evidence is most specific where the paper describes how a given method places a component in the pipeline. The false-positive removal stage in brain lesion segmentation, for example, operates on predictions after the network has made them. Reweighting in slice-based segmentation changes how training errors count before prediction. Patch selection for body part recognition changes what the second stage is trained on. Each intervention acts on a different part of the process. The review identifies those mechanisms, while the application tables usually report the outcome of the full procedure.
Limitations
Limits identified by the authors
Training data are the central limitation in the paper’s discussion. Supervised learning requires examples with target outputs, and medical image labels can be difficult to produce. A diagnosis label and a detailed delineation place different demands on an expert. The authors connect limited annotation to the prevalence of relatively shallow networks in the medical studies they survey. They also say that more target-domain training data can help even when a system starts from pretrained parameters.
The paper places transfer learning and augmentation among the responses to this problem. The former supplies a starting representation, and the latter makes additional variations of existing examples available during training. The authors also propose using larger annotated medical collections for pretraining and exploring adversarial approaches when data are scarce. These are options they identify for further investigation. The amount of clinical supervision a particular application can obtain still shapes how the problem is defined.
Computing is a separate constraint. The authors say that limited computing power increases the time required for training and that the amount of training data affects that time. Volumetric CNNs are singled out because processing three dimensions can lead to larger networks and slower prediction. This creates a practical decision about how much spatial context to preserve. Multi-view methods and designs that combine slice and volumetric processing are examples the paper discusses in response to that constraint.
The authors also identify noise and illumination as problems for image analysis and point to preprocessing as one way to reduce the effect of noise. The issue interacts with the aim of learning from pixels. The network can adapt its features during training, but the input still contains the effects of the acquisition and preparation procedures. The review describes intensity normalization and other preprocessing steps as choices made in the surveyed studies.
The paper raises the problem of understanding the internal representations. A network can supply the desired output, and its performance can be measured against a reference, while the basis for its individual decisions remains hard to explain. The review’s description of early filters and later layers gives a general account of increasing abstraction. It does not establish what a particular network relied on when it marked a lesion or assigned an image class. This is the issue the authors raise under interpretability.
The authors view improved diagnostic and detection systems as a possible consequence of progress on image-analysis performance. They also identify imaging modalities where the techniques still need to be applied. Their conclusions are broad because they describe a pattern across many applications. The practical hurdles they identify, including annotation, computation, and interpretation, depend on the data and workflow of the intended use.
Limits of the evidence in the review
The paper explains its scope through applications, architectural choices, and selected performance results. It gives no search and screening procedure from which a reader could reconstruct the set of studies considered. The breadth of the examples shows that researchers applied CNNs to many medical tasks. A claim about the typical size of a gain across the field would require a defined set of studies and a way of combining their results.
The results were also produced under the conditions of their separate studies. Dataset names and class counts are available for many entries, while details such as the division into training and test material are frequently absent from the overview. Some records count scans, some count images or slices, and some count regions. A large image count alone gives limited information about the independence of the evaluation because the unit from which those images were obtained matters. Where the paper discusses deriving patches from scans, the relationship between the patch and its parent scan is particularly important to the interpretation of an evaluation split.
A similar issue arises when scores are aggregated. Accuracy counts correct decisions overall. Its clinical meaning depends on which decisions occur often and how different kinds of errors affect the task. The authors give sensitivity and specificity as ways to examine those errors, but the applications overview mostly uses a single accuracy column. The retrieval entries also leave details about relevance judgments and the interpretation of the accuracy figures open. The individual numbers can be reported as the review lists them, and their value for a more specific comparison depends on those underlying definitions.
Several details require care even before differences among the studies are considered. The swapped comparison headings can send a reader to the wrong application, while the study names and descriptions support the correct association. The overview and prose also differ in some application references and in how they present diabetic retinopathy categories. Finally, the recall equation uses a denominator at odds with the usual meaning of recall, even though the usual fraction appears under sensitivity. These issues limit what can be inferred from a row or formula read in isolation.
The BRATS comparisons illustrate both the value and the boundary of a common benchmark name. Within the same dataset group, reporting Dice for each tumor region gives a reader a way to compare the listed results. The review does not establish identical training material, preprocessing, or evaluation subsets for every entry it gathers. Across the two challenge datasets, the reported numbers concern different dataset versions. They provide snapshots of results in those settings.
The reviewed evidence centers on technical performance against images, regions, and labels. Some examples compare with clinical readers or describe a system as a potential second reader. The review does not establish a change in clinical decisions, treatment, or patient outcomes from deploying the methods. Its forecast for clinical diagnosis rests on the possibility that better image-analysis performance can be carried into a workflow. That step depends on how the predictions are presented and used, what errors matter in that setting, and how performance holds up on the images encountered there.
What came after
The paper’s account ends with the studies it reviews and the directions the authors identify for further research. Later citing studies are unavailable for tracing which proposals were taken up or which results were extended. The documented record therefore ends with a distinction between existing applications and prospective work.
Among the prospective directions, the authors propose adapting convolutional methods to additional imaging modalities and making fuller use of volumetric information where computation permits. They also suggest acquiring larger annotated medical collections for pretraining, so that a network could start with features learned from medical images before adapting to a narrower task. These proposals follow from gaps visible in the surveyed work. The reported studies show that CNNs can support a range of image-analysis tasks under their own evaluation conditions. The authors leave open how far those results will extend across modalities, clinical settings, and the diagnostic workflows they hope the methods will support.
Cite
Cite as Syed Muhammad Anwar, Muhammad Majid, Adnan Qayyum, Muhammad Awais, Majdi R. Alnowami and Muhammad Khurram Khan. 2018. Medical Image Analysis using Convolutional Neural Networks: A Review. Journal of Medical Systems.
@article{anwar2018medical,
title = {{Medical Image Analysis using Convolutional Neural Networks: A Review}},
author = {Syed Muhammad Anwar, Muhammad Majid, Adnan Qayyum, Muhammad Awais, Majdi R. Alnowami and Muhammad Khurram Khan},
journal = {Journal of Medical Systems},
year = {2018},
doi = {10.1007/s10916-018-1088-1},
eprint = {1709.02250},
archivePrefix = {arXiv},
url = {https://doi.org/10.1007/s10916-018-1088-1}
}This page in Markdown https://md.research.elamur.ai/free/en/papers/anwar-2018-medical-image-analysis-convolutional-neural/