In a liquid xenon detector, the amount of light produced by a particle interaction is only part of what determines the signal. The detector also has to deliver that light to its sensors. On the way, a photon can change direction in the xenon, reflect off the chamber lining, or disappear into an electrode. In a chamber as large as the proposed DARWIN detector, the paths that survive can have very different lengths. The authors ask how much of the emitted light reaches a sensitive surface, how quickly it gets there, and which changes to the chamber would improve those outcomes. They use Chroma, a photon tracker that applies GPU & parallel computing to the problem.
Before using Chroma to judge designs, the authors compare it with Geant4, the toolkit used in DARWIN’s existing simulation pipeline. The checks uncover an error in Chroma’s treatment of Rayleigh scattering, the process that redirects photons in the xenon. The authors replace the angular sampling routine in their local copy and conduct the comparison with the revised software. In a setup with the electrodes removed and their support frames made nonreflective, Chroma estimates that 52.7% of photons emitted throughout the active volume reach a sensitive surface. Geant4 gives 53.4%. For this tracking task, Chroma runs 8 to 24 times as fast as Geant4 across the hardware combinations tested.
With the baseline hardware present, Chroma gives an average light collection efficiency of 43.1%. Absorption in the liquid removes 22.7% of the emitted photons, and the electrodes and their frames remove 18.0%. The largest loss at any individual electrode is at the gate, immediately below the liquid surface. In the simulation, a reflective coating on the electrodes and frames raises collection to 51.8% at the baseline liquid absorption length. Combining the coating with an optimistic assumption about xenon purity gives 67.0%. The latter configuration also takes longer to gather its light.
Moving sensors to new locations changes the relationship between yield and timing. Side sensors bring the time needed to gather most of the eventual arrivals down from about 200 ns to around 110 ns. With copper field-shaping rings in front of those sensors, however, fewer photons arrive overall than in the baseline chamber. Filling the upper region with liquid improves both optical measures in the single-phase study, while taking out the bottom sensor array and installing a reflector in its place leaves an average collection efficiency of 18%. The results describe photon transport under the authors’ material and geometry assumptions. A decision about the working detector also depends on charge transport, electric fields, sensor noise, and the electronics that turn arrivals into a usable signal.
Deep dive: GPU-based optical simulation of the DARWIN detector
Chroma’s GPU simulation of the DARWIN detector tests how electrode coatings, side sensors, and liquid xenon purity affect light collection. · about 34 minutes to read
The problem and its context
What the detector learns from two flashes
DARWIN was conceived as a rare-event observatory using ∼40 tonnes of natural xenon. The paper describes sensitivity goals for weakly interacting massive particles, neutrinoless double beta decay of xenon, and solar neutrinos. The collaboration presents the chamber as a larger successor to dual-phase xenon instruments that had already demonstrated tonne-level targets, energy thresholds on the keV scale, and sub-percent energy resolution at MeV energies. Those achievements motivated scaling up the technology. They also made the optical question important at the new scale, where the relative positions of emitting regions, reflecting surfaces, and sensors affect which photons make it through the chamber.
A time projection chamber uses an electric field to move charge from an interaction toward a readout region. In DARWIN’s dual-phase arrangement, the target is liquid xenon with a layer of gaseous xenon above it. An interaction in the target gives prompt scintillation, a light signal called S1. It can also free electrons. The cathode and gate establish the drift field, which moves the electrons towards the surface of the liquid. Rings outside the active region shape this field so that it is uniform. Between the gate and the anode, a stronger field extracts the electrons into the gas. They generate another flash there, called S2.
The relationship between the sizes of these flashes helps identify the interaction. The authors distinguish a nuclear recoil, in which a nucleus recoils, from an electronic recoil, which involves the electronic part of the target. The observed charge-to-light ratio, inferred from S2 relative to S1, differs between these classes. Better light collection can therefore improve their separation. It also helps the detector work with lower energy deposits and improves the precision with which it estimates energy. A change in how light reaches the sensors can have consequences even if the target and the interaction that produced the light are the same.
Arrival times add a separate consideration. A photosensor can produce a count in the absence of the desired light, an effect the paper calls dark noise. When the photons belonging to a flash arrive within a narrower interval, the opportunity for unrelated counts to coincide with the signal is smaller. In a reflective chamber, some arrivals may come well after the earliest photons. The practical value of waiting for those arrivals depends on how many extra photons a longer interval admits and how much noise accompanies them. The optical calculation can describe the first part of that tradeoff directly.
The chamber itself makes simple expectations about yield and delay unreliable. A white reflector can recover light headed towards a wall, but the recovered photon still has to find its way to an array. An electrode looks open when viewed from directly above and may nonetheless encounter a photon repeatedly if there are reflections nearby. The gas layer gives upward-moving light a material boundary with no equivalent on the direct path from the active liquid to the lower array. These are reasons to follow individual trajectories and then assemble them into a prediction for a whole flash.
Why the collaboration tried a different photon tracker
The standard approach described by the authors is to simulate many random photon histories in Geant4. This is a Monte Carlo calculation. Each history samples the outcomes that can occur during propagation, and the collection of histories estimates how frequently the detector produces each outcome. The workload scales with the number of photons and with the work required to follow an individual photon. A geometry study also repeats that workload each time the chamber layout or a material assumption changes. The authors cite an estimate that optical tracking used >95% of the CPU time in simulations of a current-generation dual-phase detector.
The paper places Chroma among alternatives that xenon groups were already considering for this part of simulation. Some offered faster tracking, a simpler way of specifying a detector, or both. Chroma was developed for optical tracking in particle physics detectors and runs its propagation code on graphics processing units. The authors connect this use of GPUs with their established use in ray tracing and cite previous claims of speedups from 50 to 400 times relative to Geant4. Whether a gain of that size would hold in DARWIN depends on the geometry, the tracking task, and the hardware used for the comparison.
Geometry preparation is another source of effort. In the workflow the authors describe, incorporating computer-aided design, or CAD, into Geant4 requires an external conversion step and import through Geometry Description Markup Language. Chroma can read a CAD file through its own import facility. A designer can thus start from the surfaces already used to describe a component. This is particularly relevant to parts such as an electrode built from many wires, where the optical consequences may depend on the physical arrangement of material and openings.
The user-facing part of Chroma is in Python, and its propagation engine is written in CUDA C. That combination fits the modular Python framework used for DARWIN’s wider analysis. The authors envision Geant4 handling the energy deposited by an interaction and Chroma taking over the optical tracking. That division gives the comparison a practical purpose. For such a handoff to be useful, Chroma has to handle the material interfaces and scattering processes on which the light prediction depends. The team therefore starts with isolated optical checks, moves to chamber-wide comparisons, and uses the validated local implementation to explore design changes.
The method, step by step
Describe the surfaces seen by the light
The first step is to specify what a photon can encounter. At either end of the baseline chamber is an array of 955 Hamamatsu R11410-21 photomultiplier tubes, abbreviated PMTs. They are packed in a hexagonal pattern. For photon tracking, the important part of an individual tube is its photocathode, the sensitive surface behind the window. The Chroma description gives it a diameter of 64 mm and places it 5 mm behind quartz. Absorbing material encloses the photocathode except on the window side. Around the tubes, conical reflectors offer a further optical path for light that falls between their entrances.
The lining and the reflectors around the tubes are made of polytetrafluoroethylene, abbreviated PTFE. The side lining encloses both the gas and liquid regions. In Chroma its cross section is a twenty-four-sided polygon inscribed in a circle of radius 1300 mm. The distance between cathode and gate is 2598 mm. The vertical coordinate is called Z and increases toward the upper sensor array. The gate lies at Z = 0 mm, the liquid surface at Z = 2 mm, and the anode at Z = 12 mm. These positions matter together. Light approaching the phase boundary from below can cross the gate on the way up and encounter it again after reflection.
The rest of the electrode system consists of screens that shield the upper and lower arrays. The upper part of the chamber thus contains the gate, anode, and an upper screen. The lower part contains the cathode and lower screen. Chroma represents each electrode as parallel stainless steel wires with diameter 200 µm. The pitches, meaning the distances between neighboring wire centers, are 5 mm in the upper assembly and 7.5 mm in the lower one. Steel support frames hold the wires. The upper frames sit beneath PTFE covers, while the lower frames have exposed surfaces in the liquid.
An optical geometry can omit components that incoming light cannot see. For the baseline, the side lining is light-tight, so the copper field-shaping rings behind it do not enter the Chroma tracking geometry. The reason for including those rings changes with the detector design. In the side-sensor variant, removing the lining opens the paths that lead to the added arrays. A photon can then hit a ring, travel between rings, or strike part of the assembly beyond them. The model of the chamber must account for all these possibilities once that route is opened.
Geant4 uses a separately constructed geometry whose key dimensions and component positions agree with Chroma’s to within 1-2 mm. Its sidewall is cylindrical. It can represent an array either by its individual PMTs or by a photosensitive disk covering the array. The disk is a faster option for calculations where that simplification is sufficient. The electrode approximation in Geant4 is different from Chroma’s explicit wires. It uses a thin disk with effective transparency set from the shadow that wires would cast on normally incident light. The assigned transparencies are 95% for the upper electrodes and 97% for the lower ones. To compare aggregate optical results without that representation difference, the authors run the comparison with both sets of electrodes taken out.
Assign the properties that govern a photon’s path
Liquid xenon emits in the vacuum ultraviolet, or VUV. The authors use a Gaussian wavelength distribution centered at 174.8 nm with a full width at half maximum of 10.2 nm. This width is the span between the wavelengths on either side of the peak at which the spectrum falls to half its maximum. The paper lists optical properties near the emission peak. Using representative values in this band lets the simulation describe how the emitted light sees the liquid, the gas, the reflector surfaces, and the windows.
Inside either xenon phase, scattering can turn the photon and absorption can terminate its path. The paper labels the characteristic lengths for these processes L Rayleigh and L abs, respectively. The best-guess Rayleigh scattering length is 36 cm in the liquid, far smaller than the chamber dimensions. The best-guess absorption length in the liquid is 50 m. Gas has different inputs, 200 m for Rayleigh scattering and 500 m for absorption. Scattering and absorption therefore have different roles in the same history. Successive scatterings can make a photon cover much more ground than the direct distance to a sensor, and that traveled distance is what exposes it to absorption.
At some interfaces the tracker calculates reflection and refraction from the optical properties of the media. The symbol n denotes the refractive index, and k denotes the extinction coefficient, which describes attenuation in the material’s optical response. At the mean scintillation wavelength the input index is 1.69 for liquid xenon and 1.60 for quartz. The authors set quartz absorption to zero in the simulation because only upper limits on the extinction coefficient were available. The window remains an optical boundary. A photon can reflect at its entrance, and transmission through it can still be followed by a miss at the photocathode.
Chroma can use the Fresnel equations to determine the behavior of a photon at a boundary from the specified optical properties and incidence conditions. The authors use index-based calculations for quartz and the xenon phases. Other surfaces receive assigned reflectivities that are independent of incidence angle. This distinction reflects the information available for the materials. An index measured in vacuum may give a misleading prediction for a surface in liquid xenon, and an optical calculation from constituent layers requires knowing what those layers are. The paper gives wet PTFE, oxidizing metal surfaces, and the entrance structure of a proposed silicon photosensor as examples of the difficulties.
An assigned reflectivity has a total and a division between two kinds of reflected path. A specular reflection follows the mirror direction. A diffuse reflection redistributes the light over directions. The paper records the relative contributions using the following ratio.
Rspec / Rdiff
Rspec is the specular contribution to the reflectivity and Rdiff is its diffuse contribution. The slash denotes division. The total reflectivity, called Rtotal in the inputs, gives the overall probability of reflection. The ratio describes how that probability is divided. PTFE in the baseline is assigned 99% total reflectivity in the liquid and 80% in the gas, with a specular-to-diffuse ratio of 0.05. Stainless steel is assigned 30% total reflectivity and a ratio of 2. Thus a photon can experience quite different outcomes at a steel wire and a neighboring patch of PTFE.
Timing studies can also include the delay between the onset of scintillation and the production of a photon. The paper describes this emission profile as a mixture of exponential decays. Written as a probability density in time, the prescription is
p(t) = (fₛ / τ₁) exp(−t / τ₁) + ((1 − fₛ) / τ₃) exp(−t / τ₃)
Here p(t) is the density for emission at elapsed time t after scintillation begins. The function exp is the exponential. The time constants τ₁ and τ₃ describe the singlet and triplet contributions, respectively. The singlet probability is fₛ, and 1 − fₛ is the remaining probability assigned to the triplet. The decay constants used are 3.5 ns and 24 ns. The singlet fraction is 0.66 for a nuclear recoil and 0.22 for an electronic recoil. When the emission profile is included, the arrival time reflects both the sampled emission delay and the time spent traveling. The comparison intended to isolate the behavior of the two trackers omits the emission delay.
Choose a source that answers the question
The photon origins and directions depend on what the authors intend to measure. To test a particular interface, they aim photons at it under prescribed conditions. To measure the response to a flash produced at a given height, they start photons at a point and draw their directions isotropically, meaning the launch has no preferred direction in space. On the central line the source position is expressed as
r⃗ = (0, 0, Z)
The vector r⃗ specifies the emission point. The two zero entries are the transverse coordinates X and Y, and Z is the selected height. Moving only Z gives an axial scan. The same source prescription can be used on either side of a boundary, so the scan can probe regions beyond the one used for the chamber-wide average.
For the chamber-wide comparison, the starting points are uniform throughout the defined active volume. That region runs from Z = -2597 mm just above the cathode to Z = -1 mm just below the gate, and extends laterally to the PTFE boundary. Each launched photon enters the collection denominator regardless of where it starts. Uniform generation makes the result a volume average under the chosen optical settings. A response map instead stores separate results for separate starting locations, so variations across the chamber remain visible.
For the baseline maps, the authors work with height and squared radius. In the transverse coordinates, the relation is
R² = X² + Y²
R is the radial distance from the chamber axis, X and Y locate the point across the chamber, and the superscript ² denotes a square. The authors expect little dependence on the angle around the axis, so they fix X at zero and increase Y to move outward. Along with the height scan, this yields a picture of how response changes approaching the ends or the wall. Individual point sources in the grid produce their own photon samples.
From chamber geometry to optical measurements
The steps in order.
Record a collection outcome and a time
The numerator for collection is a count of photons that reach sensitive areas. A photon that enters a PMT window and then hits absorbing material around the photocathode belongs among the losses. A photon that reflects from that window can remain in the simulation and reach another sensor. Light collection efficiency is therefore the fraction
LCE = Nhit / Ngen
LCE stands for light collection efficiency, Nhit counts photons that reach a photosensitive surface, and Ngen counts generated photons. The paper typically expresses LCE as a percentage. The count Nhit can also be restricted to a particular array, with the same denominator, to show how much that array contributes to the total.
This endpoint draws a line between optical delivery and the conversion of light into a sensor signal. A photon that reaches the sensitive area has satisfied the optical criterion. Photon detection efficiency describes the probability of registering a photon at the sensor, and its value can depend on the sensor type. The paper places examples of that probability on the order of 20% to 35%. The calculation of LCE leaves that factor out, which allows the authors to compare optical routes even when two candidate arrays use different sensor technologies.
The time statistic uses the photons that satisfy the collection criterion. Its definition can be expressed through their cumulative count.
N(t₉₀) / Nhit = 90%
N(t₉₀) is the count of collected photons whose arrival times are at or before t₉₀. Nhit is the total eventual collection count from the same sample. The symbol t₉₀ denotes the time by which the fraction indicated by its subscript has arrived. In a finite sample it is read as a percentile of the arrival times. Because every configuration has its own set of successful tracks, an earlier t₉₀ can describe a layout with fewer arrivals overall. Arrival-time distributions and collection efficiencies together show what has been gained or lost.
The same tracks support an accounting of terminal losses. Absorption in the liquid is tallied separately from absorption in steel or PTFE. A track ending inside a PMT before it reaches the photocathode is another category. Assigning a fate to photons that fail to reach any array helps the authors choose what to vary. They can change surface reflectivity while keeping the wire geometry fixed, or change the absorption length while leaving the rest of the chamber alone. Larger geometry trials use the same basic procedure after changing which surfaces the photons can encounter.
The data in the study are generated by these simulation runs. There is no fitted predictor or training split. Validation samples, uniform active-volume samples, and point-source grids are different ways of setting the initial conditions, each chosen for an optical question. The authors report that the relevant code and Monte Carlo data are available on request from the corresponding authors.
Experiments and results
Check the interfaces before putting the processes together
A comparison of two complete calculations can reveal a disagreement without locating it. The authors begin with setups designed to make the responsible processes identifiable. They turn off bulk absorption and scattering, take out the electrodes, and use 100% PMT detection efficiency in these interface tests. A crossing or reflection at the liquid surface or a quartz window then accounts for the main differences in where the photons arrive.
In the upward-directed test, the source below the liquid level produces 10⁵ photons. The prediction assigns 6.5% to reflection at the liquid surface. Of the 93.5% that enter the gas, the prediction is that 4.6% reflect at the quartz boundary and pass back into the liquid. The expected final allocations are 11.2% to the bottom array and 88.8% to the top. Both frameworks reproduce the array allocations within statistical uncertainty. The check exercises a route in which an arrival below the original direction of travel can result from an interaction above the liquid level.
For a different check, the authors launch 10⁶ photons at a window in the bottom array with a 75-degree angle of incidence. For this setup the predicted fraction reflected at the liquid–quartz boundary is 100%. Both frameworks produce total internal reflection, in which the photon returns into the incident medium. The reflected tracks then encounter the PTFE wall at the expected height. The authors give Chroma a cylindrical wall for this test and compare where photons later reach the bottom array. Differences in the arrival-position distributions are centered around zero. A check at the liquid–gas boundary likewise gives total internal reflection at the expected critical angle in both codes.
The authors then restore the best-guess bulk absorption and scattering lengths for a comparison as a function of height. They use 10⁵ isotropically launched photons per axial source position, from Z = -2648 mm to Z = 52 mm. The end arrays can be compared individually as well as in total. The LCE values agree within ±1% in absolute terms at every point except the last point for the top array, where they agree within ±3% in absolute terms. This locates the largest discrepancy in the height scan instead of letting the volume average absorb it.
Benchmark the active-volume average and the tracking time
For the average LCE comparison, Chroma uses 10⁷ photons and Geant4 uses 10⁶. Emission is isotropic and starting locations are uniform in the active region. The electrodes are absent and their frames are unreflective. The quoted statistical uncertainty is negligible. At the top array, the fraction of generated photons collected is 19.9% in Chroma and 20.2% in Geant4. At the bottom it is 32.8% and 33.2%, respectively. The paper reports a total difference of 0.7% in absolute terms, or 1.3% relative.
Average light collection for active-volume emission with electrodes removed
The two trackers give similar total collection under the comparison conditions.
The numbers
| System or setting | LCE % |
|---|---|
| Chroma (this paper) | 52.7 |
| Geant4 | 53.4 |
A timing comparison in the same optical setup uses the time from photon generation to arrival. The plotted distributions are for 10⁶ photons generated uniformly in the active region, with the scintillation emission profile omitted. The ratio of the Geant4 and Chroma distributions is centered at 1. Geant4 gives a t₉₀ of 166 ns and Chroma gives 164 ns, agreement to better than 2%. The distributions help check the paths in a way the collection count alone cannot. Two calculations could deliver a similar share of photons to the arrays while assigning appreciably different amounts of travel time to those arrivals.
The tracking-speed measurement repeats the average collection task and compares the time required for the same number of photons. On a GTX TITAN X, Chroma gives speedups of 11, 8, and 17 times against Geant4 on the Intel Broadwell E5-2630v4, Intel Xeon Silver 4214, and AMD Opteron 6220, in that order. On a TITAN Xp, the speedups against those same CPUs are 16, 12, and 24 times. The common workload makes the ratios interpretable as comparisons of tracking time. Their spread shows the role of the particular CPU and GPU in the measured gain.
The resulting benchmark serves two decisions in the paper. Agreement in reflection, spatial collection, and timing gives the collaboration a basis for carrying out the design studies in Chroma. The running times show the gain they can expect for the average-collection task on the tested hardware. The authors’ measured gain is smaller than the claims they cite for other Chroma applications. They suggest that the speed advantage could depend on the amount of sensor and geometry detail in the calculation.
Establish the response of the complete baseline
The design studies use the Chroma geometry with its wire electrodes and support frames included. With the best-guess material settings the two arrays collect 43.1% of the photons generated throughout the active region. The separately reported upper and lower contributions are 14.8% and 28.2%. This configuration is the reference for assessing the optical effect of changes to the real chamber design. The cross-framework benchmark had a different purpose and used a different electrode and frame setup.
The paper puts the result alongside the reported average LCE of 36% for the XENONnT detector. The authors say that they could recover only part of the optical input information from that comparison. They point to larger, unreflective wires in the XENONnT simulation as a reason to expect smaller collection there. For the controlled DARWIN comparisons, the reference remains the DARWIN baseline, whose component geometry and material assumptions are known.
The spatial study uses close to 2500 separate simulations with 10⁶ photons launched at each grid location. The total LCE varies along the height, as do the shares going to the two arrays. The point at which both arrays receive the same fraction is closer to the upper array. The lower array therefore remains an important destination even for sources substantially above the bottom of the chamber. The radial response stays within 1.5% until the source is in the last centimeter near the edge. There, the effect of individual pieces of hardware becomes more evident.
The maps show a drop in collection near the bottom perimeter. The paper connects it to the exposed steel frames of the lower electrodes. In that location, photons can encounter the comparatively low-reflectivity frame soon after emission. The corresponding upper frames have a PTFE cover, and the upper edge lacks the same feature. A small part of the chamber can therefore respond differently while the collection average remains representative of most of the volume. The spatial result also shows why treating the side boundary as a uniform reflector alone would miss a relevant local effect.
With the nuclear recoil scintillation profile included, the baseline has an average t₉₀ of around 200 ns. Using the electronic recoil singlet fraction changes t₉₀ by only 2 ns. The timing map shows earlier collection for flashes near the arrays and a relatively small radial variation. The authors note that the average t₉₀ exceeds the time for a photon to cross the chamber height without an interaction by more than an order of magnitude. They attribute much of the delay to Rayleigh scattering. Diffuse reflections also send photons along indirect routes, but the spacing across the chamber is large compared with the liquid scattering length.
Count the losses and test improvements in the liquid and at the wires
At the baseline liquid absorption length of 50 m, the simulation classifies 56.9% of generated photons as lost. Absorption in the liquid accounts for 22.7% of all generated photons. The electrode assemblies account for 18.0%, including 7.7% at the gate. The other named electrode losses are 3.1% at the cathode, 2.6% at the bottom screen, 1.7% at the anode, and 1.6% at the top screen. Frames have an entry of 1.3%. These values use all generated photons as their denominator, so they can be read directly alongside the fraction collected.
The position of the gate provides a plausible reason for its large share of losses. A photon can pass through its plane while approaching the surface and pass through again after reflection. Each encounter gives the wires another opportunity to absorb it. The paper also accounts for 7.2% of generated photons absorbed by PTFE reflectors and 9.0% absorbed in the PMTs. Of the latter, 6.3% of all generated photons are lost in the bottom tubes and 2.7% in the top tubes. The lower array has greater optical traffic in both the collection and loss tallies. The authors observe that the ratio of absorption to collection is roughly similar for the two arrays.
Impurities in the xenon, especially water and oxygen, are the stated source of liquid absorption. The authors extend the absorption-length sweep beyond the range used for the initial sensitivity study to ask what improved purity could achieve in the baseline chamber. At absorption lengths of 400-500 m, the average LCE in that sweep approaches ∼54%. The approach to a plateau shows how the calculation changes as losses in the liquid become less important. Surviving photons still have to find a sensitive surface, and loss at solid components continues to limit the eventual collection.
The coating study addresses some of those solid losses while keeping the electrode shapes. The proposed film uses reflective aluminum with a transparent protective layer of magnesium fluoride, denoted Al/MgF₂. The authors use 90% total reflectivity for the coated parts, based on thin-film calculations and experience with commercial VUV mirrors. Each run in this study uses 10⁶ photons from uniform active-volume sources. The gate-only test concentrates the change where the uncoated chamber has its largest individual electrode loss. Coating the whole electrode system also changes the fate of photons that encounter other wires or exposed frames.
Average light collection at each liquid absorption length for uniform active-volume emission
Coating all electrodes and frames gives the largest gain at either absorption length.
The numbers
| System or setting | LCE % |
|---|---|
| Bare steel at 50 m | 43.1 |
| Coated gate at 50 m | 46.0 |
| Coated electrodes and frames at 50 m | 51.8 |
| Bare steel at 500 m | 54.0 |
| Coated gate at 500 m | 58.7 |
| Coated electrodes and frames at 500 m (this paper) | 67.0 |
At 50 m, the gate-only setting delivers 16.8% of emitted photons to the upper array and 29.2% to the lower. Coating all the electrodes and frames brings the array contributions to 18.6% and 33.2%. At 500 m with the full coating they become 24.3% and 42.7%. The increase in both contributions is consistent with the coating preserving photons that can go on to reach either end. The gains from extending the absorption length and making the electrodes reflective show what happens when fewer tracks are terminated along both parts of the route.
The optimistic absorption-length case with the reflective treatment also changes the timing. The comparison reported in the coating study puts t₉₀ at ∼240 ns, up from ∼200 ns. Photons that would have been removed at an earlier stage of their paths can survive and arrive late. The larger arrival count can therefore come with a wider interval for collecting most of it.
Add a side array and put the rings in the optical path
The variant described as 4π aims to collect light from more directions by instrumenting the barrel while retaining the end arrays. The authors remove the PTFE side panels and include the 92 copper field-shaping rings that had been hidden behind them. Each ring has a height of 20 mm and a width of 5 mm. The vertical pitch is 28 mm, leaving 8 mm between neighboring edges. A side sensor placed beyond that assembly has a restricted view of the active xenon. The simulation follows photons that travel through the openings and photons that meet the copper on the way.
The authors consider a tiled array of Hamamatsu VUV4 silicon photomultipliers, or SiPMs, and an array of flat Hamamatsu R12699-406-M4 PMTs. In the first version, more than 87,000 quad SiPMs provide 12.1 m² of active area, about half of which the rings obstruct. The entrance to the sensitive area includes a thin layer with its own reflectivity. In the second version, close to 6500 flat PMTs provide 15.2 m² of active area and have quartz windows. For both versions the active surfaces are 18.6 mm behind the rings. Setting the same distance aligns one important part of the comparison while allowing the sensor sizes and entrance layers to differ.
Uniform generation of 10⁶ photons in the active region supplies the data for the side-array comparisons. The results in the chart use fully absorbing backing plates and best-guess optical properties. With bare copper rings, both layouts collect less light than the PTFE-lined baseline. Making the rings reflective recovers collection, and the flat PMT layout with coated rings surpasses the baseline. The runs that omit the rings expose the side sensors without any obstruction from that assembly. The paper includes those runs to illustrate the optical opportunity if ring obstruction could be eliminated.
Average light collection for uniform active-volume emission with barrel sensor variants
Reflective rings improve both side layouts, and removing the obstruction gives the highest yields.
The numbers
| System or setting | LCE % |
|---|---|
| Baseline with PTFE lining | 43.1 |
| Side SiPMs behind copper rings | 22.6 |
| Side SiPMs behind reflective rings | 36.9 |
| Side SiPMs without rings | 44.4 |
| Side PMTs behind copper rings | 27.7 |
| Side PMTs behind reflective rings | 46.8 |
| Side PMTs without rings (this paper) | 61.2 |
The distribution by array explains part of the loss with copper. The end arrays together receive 13.6% of the generated light in either copper-ring variant. In the baseline, the same end arrays account for all collection. The side PMTs receive 14.1% with copper rings, making the side array the largest individual contributor in that layout. Those arrivals occur alongside the loss of the reflecting wall that had sent light towards the ends. The authors attribute the flat PMT option’s superior optical collection to the larger active area and less reflection at the entrance.
The timing results favor the side arrays. Both sensor options have an average t₉₀ around 110 ns, consistent within 1 ns of one another. The maps also show a more evident radial effect than in the baseline. A photon emitted at a large radius begins nearer the side array, with a shorter route available if it passes the rings and reaches the sensitive surface. In the PTFE-lined chamber the analogous encounter at the wall usually redirects the path and leaves the photon to travel farther for collection.
The authors compare cumulative arrival curves to show how faster collection can coexist with a smaller final yield. Each curve is normalized to the eventual collection of its own design. A curve that rises sooner says that the layout receives its own arrivals sooner. To relate the timing back to actual light yield, the paper considers cutting off the baseline at the t₉₀ of the side PMT design. With that time window the effective LCE of the baseline would be close to the side variant’s average LCE. This illustrates the dependence of the optical comparison on how much of the tail a detector readout is prepared to use.
Change the upper medium or remove the lower sensors
The single-phase study extends liquid xenon up to the upper array, eliminating the phase boundary traversed by light in the baseline. The broader detector concept would increase the electric field between gate and anode enough to produce proportional scintillation in the liquid. The optical calculation examines the effect of filling the upper region with liquid while keeping the change to the geometry small. Its axial scan uses 10⁵ isotropically emitted photons for each position from Z = -2648 mm to Z = 52 mm.
In the single-phase case, the height curves show a smaller imbalance between the contributions from the bottom and top arrays. The paper reports an increase in average collection of 4.9% in absolute terms and 11% in relative terms. The change also brings t₉₀ from about 200 ns to 175 ns. Removing reflection at the liquid–gas boundary removes one reason for an upward-going photon to return to the liquid and take a longer route. The observed changes in both the array shares and timing are consistent with that change in optical access to the top.
The final trial replaces the bottom PMT array with a PTFE film assigned 99% reflectivity. The potential motivation is to reduce the number of tubes and their electronics, with consequences for cost and background. In this geometry, the only photosensitive array is above the active region. The volume average LCE falls to 18%, and near the bottom the collection is smaller by a factor of ∼3, as reported for the spatial study. A lower reflector can return a photon to the xenon, but collection still requires the surviving path to reach the far end of the chamber.
For the same top-only configuration, extending the liquid absorption length from 50 m to 500 m increases average LCE by ∼7.5%, according to the paper. The resulting collection remains well below the complete baseline. The time statistic also worsens, with t₉₀ reaching 265 ns. These results show the contribution of local collection at the bottom in the baseline chamber. Its photosensitive surfaces terminate successful paths in a region from which a photon headed to the top would have much farther to go.
What the ablations show
Vary the uncertain properties individually
The authors change one optical input at a time, setting it to the lower and upper ends of its assumed spread while leaving other inputs at their best guesses. When the liquid absorption length varies from 20 m to 100 m, the average baseline LCE spans 32% to 49%. The Rayleigh scattering-length variation, from 20 cm to 50 cm, gives LCE values spanning 40% to 45%. Varying the liquid-facing PTFE reflectivity from 93% to 100% gives a span of 34% to 45%. These comparisons indicate that, over the ranges tested, uncertainty in liquid absorption and PTFE reflectivity produces the larger changes in average collection.
The scattering result concerns eventual yield. The baseline timing study shows that scattering can still be central to the time photons spend in the chamber. Changing a photon’s direction can postpone its arrival, while an absorption removes it from the count altogether. A long trajectory also provides more chances for a later absorption or surface encounter. This connection explains why the two measurements convey different information about the same physical processes. The extended purity sweep adds that even a large reduction in liquid losses has a limit if the rest of the chamber remains the same.
Identify which code differences affect the optical estimate
The authors discovered a special case in Chroma’s specular reflection code when a ray strikes a surface straight on. The plane of incidence is ordinarily determined from the incoming direction and the surface normal, the direction perpendicular to the surface. When the directions are parallel, their cross product cannot specify a plane. The refraction and diffuse reflection branches handled this case, but the original specular branch could end the photon track. The authors repaired the local code and found no noticeable effect on LCE. Exact normal incidence occurs too rarely in their realistic source simulations to affect the aggregate appreciably.
A second issue appears at the join of two reflecting planes. A photon that hits the intersection fails to reflect, apparently because the adjoining planes supply conflicting surface normals. The authors leave the code for this case as it was. They explicitly compare the segmented reflector with a cylinder and observe no perceptible difference in average LCE. In the chamber calculation, the geometry change is a way to gauge the practical relevance of an error at a very particular location.
The scattering problem has a wider effect. The original Chroma routine generates a different distribution of angles between the incoming and scattered directions from the one in Geant4, and the authors also identify differences involving polarization. They compare the angular distribution with the theoretical expectation and adopt the Geant4 routine, which reproduces that expectation. The correction lowers the Chroma average LCE by a couple of percent. The result distinguishes a process acting throughout the xenon from edge cases at a special incidence or at an exact boundary join. The comparison results use the amended local installation.
Test whether the coating benefit depends on the kind of reflection or electrode
For the standard coating calculation, the authors treat 85% out of the 90% total reflection as specular. They repeat the calculation with 85% out of the same total assigned to diffuse reflection. Average LCE changes by only ∼0.2%. This is a controlled comparison at fixed total reflectivity. Under these conditions, the predicted yield from making the surface highly reflective is insensitive to the tested reassignment of the reflected light between specular and diffuse paths. The quantity assessed by that test is average collection.
The comparison also extends to electrode constructions other than parallel wires. In one trial every electrode becomes a hexagonal mesh with 178 µm wires and 10.2 mm openings. The simulated average LCE is 51% with the coating and 43% without it. In another, only the gate uses a mesh, with 3.5 mm openings. The values for that trial are 45% coated and 40% uncoated. In each pair the openings and electrode layout remain the same when the coating is changed. The result supports the optical benefit in the mesh arrangements actually evaluated and shows that different electrode designs can have different initial collection levels.
The gate-only test narrows down where the coating can help. It targets the largest individual electrode loss and recovers some of the yield attainable with a full treatment. The full coating captures a further gain, meaning that loss on the other wires and frames remains relevant even though each is a smaller sink than the gate. Repeating both treatments with a longer liquid absorption length shows how the result depends on the medium in which reflected photons continue their paths. A reflection is valuable to eventual collection only if the returning photon can survive the rest of the trip.
Separate obstruction, reflection, and losses behind the side sensors
The side-array runs include a comparison of quartz and silicon as backing-plate materials. The outcomes agree within statistical error, which the authors attribute to the tight packing of the sensors. With little exposed backing, changing its optical properties has little effect in that comparison. They then use fully absorbing backing plates as a conservative assumption. This choice helps specify what the main side-array results represent.
Changing the rings gives a much stronger response. A coating changes the optical fate of photons that hit a ring while leaving the physical opening in place. Omitting the rings changes access to the sensors as well. The increase seen in each comparison shows how both the reflectivity and the obstruction matter. Individual array counts identify a further effect of the overall barrel redesign. Once the PTFE panels are gone, the end arrays lose contributions from paths previously redirected by the lining. The gain at the barrel must be understood together with that loss of light at the ends.
The side-sensor alternatives also illustrate the limits of attributing a comparison to a single component. Equal setbacks from the rings make their placement comparable, and the results favor the flat PMTs. The designs still differ in sensitive area and entrance reflection. The paper explains the advantage using both properties. The comparison with and without the rings more directly tests obstruction, because within a sensor variant the photosensitive assembly stays in place while the ring setting changes.
Limitations
Limits the authors identify
Several material properties used in the paper lack reliable measurements in the relevant environment. VUV reflectivity can depend on surface finish and oxidation, and some available optical constants describe conditions different from those inside the chamber. The upper limits for quartz absorption and the unknown layer composition of some photosensors illustrate different reasons for choosing a simplified optical input. A large sample of tracks can make the statistical uncertainty in a result negligible while leaving the calculated value sensitive to those choices. The authors call for more measurements at the relevant wavelengths and in liquid xenon.
For the proposed reflective coating, the assigned 90% reflectivity is an assumption about a realizable surface. The thin-film calculation gives an angle dependence of ∼10%-15% after accounting for the wavelength distribution of the scintillation, and the tracking study ignores that dependence. The authors indicate that a dedicated measurement would be needed to establish the coating’s reflectivity. They also leave charge accumulation, spurious electron emission, background contributions, and mechanical stability outside the optical study. A coating that sends more VUV photons back into the liquid must still function as part of an electrode assembly.
The two frameworks retain a small unexplained disagreement after correction of the Chroma implementation. The authors suggest remaining geometry differences or details of the optical algorithms as possible sources and leave the cause for further work. The tracking speed comparison also applies to the benchmark configuration and tested hardware. The paper raises the possibility of larger speed gains with more detailed or sensor-rich geometries without measuring that effect in the reported benchmark.
For the side designs, the sensor position relative to the rings is preliminary. The rings help maintain the drift field, so increasing their spacing or shrinking them for optical access raises a question about field uniformity. Sensor operation near the rings also warrants investigation. The paper identifies dark noise from the area added at the sides as a concern even for a PMT array. In the single-phase case the authors consider their geometry change minimal and suggest that thinner, more widely spaced anode wires could give a further optical gain. The intended operation also requires a sufficiently strong field to produce proportional scintillation in the liquid.
According to the authors, a design study is complete when it covers how energy is deposited, how electrons drift and diffuse, how signals coincide with dark noise, and how the electronics operate. Those processes determine how many optical arrivals contribute to a measured event and how the event will be reconstructed. A favorable LCE or t₉₀ gives information for that calculation. The simulated improvement in either quantity alone leaves the effects on the observatory’s physics reach open.
Limits of what the comparisons establish
The validation is a comparison of software predictions and, in the interface tests, of predictions with expected optical behavior. It gives confidence in the checked processes under the chosen conditions. It provides no detector measurement of the full DARWIN geometry. The electrode omission in the average comparison is especially important. It makes the comparison interpretable in spite of differing electrode representations, while the baseline estimate and coating studies depend on the explicit wires and frames present in Chroma. Agreement for the benchmark therefore has a narrower reach than a direct check of the complete detector and all its variants.
The uniform emission average weights positions according to volume. Its value applies to that distribution even though the spatial studies show sizable differences with height and a local feature near the lower frame. The radial maps also depend on the authors’ expectation of small azimuthal variation, since they sample the radial direction along a fixed transverse line. These choices are appropriate to the outputs the paper presents. They give limited evidence about small variations around the circumference or about an average for events concentrated in particular regions.
The one-property sweeps are conditional on the other inputs. Their endpoints show the response to the specified ranges and do not assign probabilities to the optical properties or quantify their joint uncertainty. The combined coating and purity calculation explores a particular pair of favorable conditions. Its 67.0% is the collection estimate for that scenario. Similarly, the highest side-array result quantifies an optical layout with the rings absent, leaving the function those rings perform in the actual chamber outside that comparison.
Finally, LCE treats arrival at a sensitive area as success. Different sensor technologies can turn different shares of those arrivals into registered signals. Also, a t₉₀ defined among successful arrivals can become shorter when a geometry eliminates paths that would otherwise have produced late light. For a specified time window, the optical quantity of interest is how much of the original emission arrives during that interval, as the authors’ cumulative comparison illustrates. Converting that quantity into a usable signal depends on sensor response, noise, and readout.
What came after
The paper proposes integrating Chroma’s optical engine with DARWIN’s broader simulation. That would connect the photon arrival distributions to the energy deposition, the movement of charge, and the readout. The authors also identify material measurements as a way to refine the optical inputs. A measurement of electrode reflectivity in the relevant environment, for instance, would constrain the surface property on which the predicted coating gains depend.
These are follow-up directions proposed by the authors. Subsequent studies that adopted or extended this calculation are undocumented here.
Cite
Cite as L. Althueser, B. Antunovic, E. Aprile, D. Bajpai, L. Baudis, D. Baur, A. L. Baxter, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, A. Brown, R. Budnik, A. Chauvin, A. P. Colijn, J. J. Cuenca-Garcia, V. D'Andrea, P. Di Gangi, J. Dierle, S. Diglio, M. Doerenkamp, K. Eitel, S. Farrell, A. D. Ferella, C. Ferrari, C. Findley, H. Fischer, M. Galloway, F. Girard, R. Glade-Beucke, L. Grandi, M. Guida, S. Hansmann-Menzemer, F. Jorg, L. Jones, P. Kavrigin, L. M. Krauss, B. von Krosigk, F. Kuger, H. Landsman, R. F. Lang, S. Li, S. Liang, M. Lindner, J. Loizeau, F. Lombardi, T. Marrodan Undagoitia, J. Masbou, E. Masson, J. Matias-Lopes, S. Milutinovic, C. M. B. Monteiro, M. Murra, K. Ni, U. Oberlack, I. Ostrovskiy, M. Pandurovic, R. Peres, J. Qin, M. Rajado Silva, D. Ramirez Garcia, P. Sanchez-Lucas, J. M. F. dos Santos, M. Schumann, M. Selvi, F. Semeria, H. Simgen, M. Steidl, P.-L. Tan, A. Terliuk, K. Thieme, R. Trotta, C. D. Tunnell, F. Tonnies, K. Valerius, S. Vetter, G. Volta, W. Wang, C. Wittweg and Y. Xing. 2022. GPU-based optical simulation of the DARWIN detector. arXiv:2203.14354 · JINST 17 (2022) P07018.
@misc{althueser2022gpu,
title = {{GPU-based optical simulation of the DARWIN detector}},
author = {L. Althueser, B. Antunovic, E. Aprile, D. Bajpai, L. Baudis, D. Baur, A. L. Baxter, L. Bellagamba, R. Biondi, Y. Biondi, A. Bismark, A. Brown, R. Budnik, A. Chauvin, A. P. Colijn, J. J. Cuenca-Garcia, V. D'Andrea, P. {Di Gangi}, J. Dierle, S. Diglio, M. Doerenkamp, K. Eitel, S. Farrell, A. D. Ferella, C. Ferrari, C. Findley, H. Fischer, M. Galloway, F. Girard, R. Glade-Beucke, L. Grandi, M. Guida, S. Hansmann-Menzemer, F. Jorg, L. Jones, P. Kavrigin, L. M. Krauss, B. {von Krosigk}, F. Kuger, H. Landsman, R. F. Lang, S. Li, S. Liang, M. Lindner, J. Loizeau, F. Lombardi, T. Marrodan Undagoitia, J. Masbou, E. Masson, J. Matias-Lopes, S. Milutinovic, C. M. B. Monteiro, M. Murra, K. Ni, U. Oberlack, I. Ostrovskiy, M. Pandurovic, R. Peres, J. Qin, M. Rajado Silva, D. Ramirez Garcia, P. Sanchez-Lucas, J. M. F. {dos Santos}, M. Schumann, M. Selvi, F. Semeria, H. Simgen, M. Steidl, P.-L. Tan, A. Terliuk, K. Thieme, R. Trotta, C. D. Tunnell, F. Tonnies, K. Valerius, S. Vetter, G. Volta, W. Wang, C. Wittweg and Y. Xing},
year = {2022},
doi = {10.1088/1748-0221/17/07/p07018},
eprint = {2203.14354},
archivePrefix = {arXiv},
url = {https://doi.org/10.1088/1748-0221/17/07/p07018}
}This page in Markdown https://md.research.elamur.ai/free/en/papers/althueser-2022-gpu-based-optical-simulation-darwin/